Skip to main content
Log in

Intraoperative measurement of javid shunt flow with transit-time ultrasound

  • Papers Presented at the Southern California Vascular Surgical Society
  • Published:
Annals of Vascular Surgery

Abstract

Transit-time ultrasound methods were used to measure blood flow in 37 patients undergoing carotid endarterectomy. Internal carotid flow before (ICFbef) and after (ICFaft) endarterectomy was measured with a 6 mm perivascular probe, and Javid shunt flow (SF) was measured with a clamp-on probe. For the entire group ICFbef averaged 117±67 ml/min and ICFaft was 173±67 ml/min. Shunt flow averaged 123±51 ml/min. The differences between ICFbet and ICFaft and between SF and ICFaft were significant (ANOVA,p<0.01) but the difference between ICFbef and SF was not. The relationship between ICFbef and SF appeared to define two groups of patients. Those in whom SF was greater than ICFbef (SF > ICFbef) had more stenosis evident on preoperative arteriograms (64.7%±14.55% maximum single diameter stenosis) and a greater average increase in ICF (151%±159%) than those with SF ≤ ICFbef (43.3%±20.9% stenosis and 34%±54% increase in ICF), suggesting that the relationship between SF and ICFbef defines groups with different hemodynamic responses. The similarity between SF and ICFbef indicates that Javid shunt flow offers adequate protection from cerebral ischemia. A practical benefit of the shunt clamp-on flow probe is the ability afforded to recognize shunt occlusions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Boysen G. Cerebral hemodynamics in carotid surgery. Arch Neurol Scand 1973;49(Suppl 52):3–86.

    Google Scholar 

  2. Lassen NA, Christiansen MD. Physiology of cerebral blood flow. Br J Anaesth 1976;48:719–734.

    PubMed  CAS  Google Scholar 

  3. Sundt TM, Sharbrough FW, Piepglas DG, et al. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy. Mayo Clin Proc 1981;56:533–543.

    PubMed  Google Scholar 

  4. Sundt TM, Sharbrough FW, Anderson RE, et al. Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy. J Neurosurg 1974;41:310–320.

    PubMed  Google Scholar 

  5. Padayachee TS, Gosling RG, Bishop CC, et al. Monitoring middle cerebral artery blood velocity during carotid endarterectomy. Br J Surg 1986;73:98–100.

    PubMed  CAS  Google Scholar 

  6. McDowell HA, Gross GM, Halsey JH. Carotid endarterectomy monitored with transcranial Doppler. Ann Surg 1992;215:514–518.

    PubMed  Google Scholar 

  7. Gee W, McDonald KM, Kaupp HH. Carotid endarterectomy shunting: Effectiveness determined by operative ocular pneumoplethysmography. Arch Surg 1979;114:720–721.

    PubMed  CAS  Google Scholar 

  8. Burton RG, Gorewit RC. Ultrasonic flowmeter—uses of wide beam transit-time technique. Med Elect 1984;15:68–73.

    Google Scholar 

  9. Mayber MR, Wilson SE, Yatsu F, et al. Carotid endarterectomy and prevention of cerebral ischemia in symptomatic carotid stenosis. JAMA 1991;266:3289–3294.

    Article  PubMed  Google Scholar 

  10. Movius HJ, Zubar WF, Gaspar MR, et al. Carotid thrombo-endarterectomy and results. Arch Surg 1968;94:585–590.

    Google Scholar 

  11. Eidt JF, Kahn MB, Barone GW, et al. Malfunction of a double balloon carotid shunt as a result of herniation of the proximal balloon. J Vasc Surg 1990;12:62–64.

    PubMed  CAS  Google Scholar 

  12. Artro AA, Strandness DE. Delayed carotid shunt occlusion detected by encephalographic monitoring. J Clin Monit 1989;5:119–122.

    Article  PubMed  Google Scholar 

  13. Loftus CM, Silvidi JA, Becker JA, et al. Correlation of experimental rCBF determinations in goats with flow measurements from a Doppler-modified carotid artery shunt. J Ultrasound Med 1989;8:7–13.

    PubMed  CAS  Google Scholar 

  14. Boysen G, Ladegaard HJ, Pedersen N, et al. Cerebral blood flow and internal carotid artery flow during cartoid surgery. Stroke 1970;1:252–260.

    Google Scholar 

  15. Tindall GT, Odom GL, Copp HB, et al. Studies on carotid artery flow and pressure. Observations on 18 patients during graded occlusion of the proximal carotid artery. J Neurosurg 1962;19:917–923.

    Article  PubMed  CAS  Google Scholar 

  16. Archie JP, Feldtman RW. Critical stenosis of the internal carotid artery. Surgery 1981;89:67–70.

    PubMed  Google Scholar 

  17. Beard JD, Horrocks M. Measurement of blood flow in carotid shunts. Surg Res Commun 1987;1:21–25.

    Google Scholar 

  18. Leopold PW, Shadall AA, Feustell P, et al. Duplex scanning of the internal carotid artery: An assessment of cerebral blood flow. Br J Surg 1987;74:630–633.

    PubMed  CAS  Google Scholar 

  19. Fortune JB, Bock D, Kupinski AM, et al. Human cerebrovascular response to oxygen and carbon dioxide as determined by internal carotid artery duplex scanning. J Trauma 1992;32:618–627.

    Article  PubMed  CAS  Google Scholar 

  20. Wong DH, Watson T, Gordon I, et al. Comparison of changes in transit time ultrasound, esophageal Doppler, and thermodilution cardiac output after changes in preload, afterload, and contractility in pigs. Anaesth Analg 1991;72:584–588.

    CAS  Google Scholar 

  21. Gorewit RC, Bristol DG, Aromando M, et al. Mammary blood flow of cows measured by ultrasonic and electromagnetic flow meter. J Dairy Sci 1984;67(Suppl):159.

    Google Scholar 

  22. Wilkening RB, Boyle DW, Meschia G. Measurement of blood flow and oxygen consumption in the pelvic limb of the fetal sheep. Proc Soc Exp Biol Med 1988;187:498–505.

    PubMed  CAS  Google Scholar 

  23. Aufiero TX, Thiele BL, Rossi JA, et al. Hemodynamic performance of carotid artery shunts. Am J Surg 1989;158:95–99.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Gordon, I.L., Weil, D.J., Williams, R.A. et al. Intraoperative measurement of javid shunt flow with transit-time ultrasound. Annals of Vascular Surgery 8, 571–577 (1994). https://doi.org/10.1007/BF02017414

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02017414

Keywords

Navigation