Skip to main content
Log in

Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology

  • Original Articles
  • Published:
Annals of Vascular Surgery

Abstract

The aim of this prospective study was to analyze the outcome of elective endoluminal grafting in patients with various morphologies of abdominal aortic aneurysms (AAA). Between May 1992 and May 1994, endoluminal repair of AAA was undertaken in 40 patients. After detailed imaging by means of CT scanning and arteriography, aneurysms were classified into one of two types according to the following criteria: type I (suitable for transfemoral implantation of a straight tube graft), AAA with a proximal neck (2 cm or longer), a distal neck (1.5 cm or longer), and an iliac artery diameter of 8 mm or greater (N=19); or type II (requiring tapered aortoiliac or bifurcated grafts or access through an iliac approach), AAA that did not fit the type I criteria (N=21). Radiographic guidance was used to pass the aortic endografts (38 Dacron and 2 PTFE) via a delivery sheath introduced through the femoral or iliac arteries into the aorta. The configuration of the aortic endografts was tubular in 26 patients, tapered aortoiliac in 11, and bifurcated in three. Successful endoluminal repair was achieved in 17 (89%) of 19 patients with type I AAA and in 15 (71%) of 21 patients with type II AAA. All failed endoluminal repairs proceeded to successful open repair, and there were no deaths during the period of hospitalization for the operation. The mean operative time and mean hospital stay were shorter in patients with type I AAA compared to patients with type II AAA. The incidence of postoperative complications was 37% in type I endoluminal repairs compared to 71% in type II endoluminal repairs. There was one cardiac death (procedure related) within 30 days, and there were three late deaths (one cardiac, one from liver failure in a type II AAA repair, and one from a ruptured esophagus in a type I repair). These preliminary results suggest that there is a better outcome in transfemoral endoluminal tube graft repair of aneurysms conforming to type I criteria compared to endoluminal repair of the more complex type II AAA.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dotter CT. Transluminally-placed coil spring endarterial tube grafts: Long-term patency in canine popliteal artery. Invest Radiol 1969;4:329–332.

    PubMed  Google Scholar 

  2. Balko A, Piasecki GJ, Shar DM, et al. Transfemoral placement of intraluminal polyurethane prosthesis for abdominal aortic aneurysm. J Surg Res 1986;40:305–309.

    Article  PubMed  Google Scholar 

  3. Lawrence DD, Charnsaugavej C, Wright KC, et al. Percutaneous endovascular graft: Experimental evaluation. Radiology 1987;163:357–360.

    PubMed  Google Scholar 

  4. Parodi JC, Palmaz JC, Barone HD. Tratamiento endoluminal de los aneurismas de aorta abdominal: Estudio experimental. Presented at II Convencion de Cirujanos Vasculares de Habla Ispana. Buenos Aires: October 30, 1990, p 122.

  5. Laborde JC, Parodi JC, Clem MF, et al. Intraluminal bypass of abdominal aortic aneurysm: Feasibility study. Radiology 1992;184:185–190.

    PubMed  Google Scholar 

  6. Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491–499.

    Article  PubMed  Google Scholar 

  7. May J, White G, Waugh R, et al. Treatment of complex abdominal aortic aneurysms by a combination of endoluminal and extraluminal aortofemoral grafts. J Vasc Surg 1994;19:924–933.

    PubMed  Google Scholar 

  8. May J, White G, Yu W, et al. Transluminal placement of aorto-iliac grafts for treatment of large abdominal aortic aneurysms. In Weimann S, ed. Thoracic and Thoracoabdominal Aortic Aneurysm. Bologna, Italy: Monduzzi Editore, 1994.

    Google Scholar 

  9. May J, White G, Yu W, et al. Endoluminal stent-grafts for intrathoracic and abdominal aortic aneurysm. In Liermann DD, ed. Stents: State of the Art and Future Developments. Morin Heights, Canada: Polyscience Publications, 1995.

    Google Scholar 

  10. White GH, May J, Yu W. Stented and non-stented grafts for aneurysmal disease: The Sydney experience. In Chuter T, Donayre C, White R, eds. Endoluminal Vascular Prostheses. Boston: Little Brown, 1995, pp 107–152.

    Google Scholar 

  11. White GH, Yu W, May J, et al. A new non-stented endoluminal graft for straight or bifurcated repair of aneurysms. J Endovasc Surg 1994;1:16–24.

    Article  PubMed  Google Scholar 

  12. Moore WS. Endovascular grafting technique: A feasibility study. In Yao JST, Pearce WH, eds. Aneurysms: New Findings and Treatments. Norwalk, Conn.: Appleton & Lange, 1994, pp 333–340.

    Google Scholar 

  13. Chuter TAM, Green RM, Ouriel K, et al. Transfemoral endovascular aortic graft replacement. J Vasc Surg 1993;18:185–197.

    Article  PubMed  Google Scholar 

  14. Parodi JC. Endovascular repair of abdominal aortic aneurysms. In Whittemore A, ed. Advances in Vascular Surgery. St. Louis: Mosby-Year Book, 1993, pp 85–106.

    Google Scholar 

  15. May J, White G, Yu W, et al. Endoluminal repair of complex abdominal aortic aneurysms. In Yao JST, Pearce WH, eds. Arterial Surgery: Management of Challenging Problems. Norwalk, Conn.: Appleton & Lange, 1995.

    Google Scholar 

  16. May J, White G, Waugh R, et al. Transluminal placement of a prosthetic graft-stent device for treatment of subclavian artery aneurysm. J Vasc Surg 1993;18:1056–1059.

    Article  PubMed  Google Scholar 

  17. May J, White GH. Combined surgical and endovascular approaches. In White RA, Fogarty TJ, eds. Peripheral Endovascular Interventions. St. Louis: Mosby-Year Book, 1996.

    Google Scholar 

  18. May J, White GH, Yu W, et al. Endoluminal grafting of abdominal aortic aneurysms: Causes of failure and their prevention. J Endovasc Surg 1994;1:44–52.

    Article  PubMed  Google Scholar 

  19. Ad Hoc Committee on Reporting Standards, Rutherford RB, Flanigan DP, et al. Suggested standards for reports dealing with lower extremity ischemia. J Vasc Surg 1986;4:80–94.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

May, J., White, G.H., Yu, W. et al. Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology. Annals of Vascular Surgery 10, 254–261 (1996). https://doi.org/10.1007/BF02001891

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02001891

Keywords

Navigation