Basic Research in Cardiology

, Volume 75, Issue 1, pp 262–269 | Cite as

Comparative studies of ventricular ejection phase parameters for the detection of impaired cardiac function

  • J. H. Bürsch
  • H. H. Hagemann
  • B. Koch
  • P. H. Heintzen
Article
  • 20 Downloads

Summary

Experimental studies were carried out in 11 anesthetized pigs in order to compare the sensitivity of left ventricular ejection phase parameters as determined by quantitative angiocardiographic methods, for detection of mild or moderate ventricular dysfunction. The experimental setup implied various degrees of nonadequate muscular hypertrophy in relation to chronic volume overload by aortic insufficiency. Left ventricular stroke volume, flow, ejection fraction and mean circumferential fiber shortening did not demonstrate impairment of ventricular function reserve when studied in the resting state of the circulation, but became indicative to some degree by their abnormal pattern of response to acute afterload stress (angiotensin infusion). Mean normalized systolic ejection rate as well as normalized values of systolic ejection time were found to be the most sensitive indices of ventricular function in this study.

Keywords

Ventricular Function Volume Overload Ejection Time Aortic Insufficiency Ejection Rate 

Vergleichende Untersuchungen von ventrikulären Auswurfparametern zur Aufdeckung einer kardialen Funktionseinschränkung

Zusammenfassung

Es wurden experimentelle Untersuchungen an 11 narkotisierten Schweinen mit dem Ziel durchgeführt, die unterschiedliche Empfindlichkeit verschiedener angiokardiographisch gewonnener Auswurfparameter des linken Ventrikels zur Aufdekkung einer ventrikulären Funktionseinschränkung zu überprüfen. Die Experimente schlossen Zustände mit akuter und chronischer Volumenbelastung durch Aortenklappeninsuffizienz ein, wobei die Untersuchungen zu verschiedenen Zeiten mit unterschiedlichem Grad der Muskelhypertrophie-Entwicklung durchgeführt wurden. Das linksventrikuläre Schlagvolumen, die Stromstärke, die ventrikuläre Auswurffraktion und die mittlere zirkumferentielle Verkürzungsgeschwindigkeit zeigten unter Ruhebedingungen des Kreislaufs keine Einschränkung der ventrikulären Funktionsreserve an. Sie wurden in gewissem Grade empfindlich durch das abnorme Verhalten der Meßwerte bei Nachlast-Erhöhung durch Angiotensin-Infusion. Die mittlere normalisierte systolische Auswurfrate und die normalisierten Werte der systolischen Austreibungszeit erwiesen sich in dieser Studie als die empfindlichsten Parameter zur Beurteilung der Ventrikelfunktion.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Bolen, J. L., E. L. Holloway, J. C. Zener, D. C. Harrison, E. L. Alderman: Evaluation of left ventricular function in patients with aortic regurgitation using afterload stress. Circulation53, 132 (1976).PubMedGoogle Scholar
  2. 2.
    Bürsch, J. H., P. H. Heintzen, R. Simon: Videodensitometric studies by a new method of quantitating the amont of contrast medium. Europ. J. Cardiol.1, 437 (1974).Google Scholar
  3. 3.
    McCullagh, W. H., J. W. Covell, J. Ross Jr.: Left ventricular dilation and diastolic compliance changes during chronic volume overloading. Circulation45, 943 (1972).PubMedGoogle Scholar
  4. 4.
    Elzinga, G., V. Westerhof: How to quantify pump function of the heart. The value of variables derived from measurements on isolated muscle. Circulat. Res.44, 303 (1979).PubMedGoogle Scholar
  5. 5.
    Gault, J. H., J. W. Covell, E. Braunwald, J. Ross Jr.: Left ventricular performance following correction of free aortic regurgitation. Circulation42, 773 (1970).PubMedGoogle Scholar
  6. 6.
    Heintzen, P. H., V. Malerczyk, J. Pilarczyk, K. W. Scheel: On-line processing of the video image for left ventricular volume determination. Comp. Biomed. Res.4, 474 (1971).CrossRefGoogle Scholar
  7. 7.
    Heintzen, P. H., K. Moldenhauer, P. E. Lange: Three-dimensional computerized contraction pattern analysis. Europ. J. Cardiol.1, 229 (1974).Google Scholar
  8. 8.
    Heintzen, P. H., E. Stephan: Dynamic geometry of the left ventricle in hypertrophy studied by quantitative angiocardiography. Basic Res. Cardiol.72, 190 (1977).CrossRefPubMedGoogle Scholar
  9. 9.
    Lange, P. E., D. Onnasch, F. L. Farr, P. H. Heintzen: Angiocardiographic left ventricular volume determination. Accuracy, as determined from human casts, and clinical application. Europ. J. Cardiol.8, 449 (1978).Google Scholar
  10. 10.
    Ronan, J. A., R. B. Steelman, J. P. Schrank, P. T. Cochran: The angiotensin infusion test as a method of evaluating left ventricular function. Clin. Comm.89, 554 (1975).Google Scholar
  11. 11.
    Ross, J. Jr.,E. Braunwald: The study of left ventricular function in man by increasing resistance to ventricular ejection with angiotensin. Circulation29, 739 (1964).Google Scholar
  12. 12.
    Ross, J., D. Franklin, S. Sasayama: Preload, afterload and the role of afterload mismatch in the descending limb of cardiac function. Europ. J. Cardiol.4, 77 (1976).Google Scholar

Copyright information

© Dr. Dietrich Steinkopff Verlag 1980

Authors and Affiliations

  • J. H. Bürsch
    • 1
  • H. H. Hagemann
    • 1
  • B. Koch
    • 1
  • P. H. Heintzen
    • 1
  1. 1.Department of Pediatric Cardiology and Biomedical EngineeringUniversity of KielFRG

Personalised recommendations