Summary
A Verzár condensation nucleus counter with automatic recording was tested under constant and controlled conditions in the laboratory and compared with the standard photo-electric nucleus counter of high precision of the School of Cosmic Physics. The photographic records of the fog formation in the cylindrical cloud chamber of theVerzár automat made with galvanometers of 0.019 sec and 1.0 sec periods show that a galvanometer of 1 sec period cannot follow the rapid formation and disappearance of the fog, apparently due to the horizontal arrangement of the fog tube and the absence of an insulating wet lining.
TheVerzár automat is an excellent apparatus for continuously recording concentration of condensation nuclei. Its calibration curve, however, would require adjustment if the photo-electric nucleus counter of the School of Cosmic Physics in Dublin were accepted as standard. A new calibration curve deduced from the Dublin comparisons made so far is given.
Zusammenfassung
Ein Kondensationskernzähler mit automatischer Registrierung nachF. Verzár wurde im Laboratorium unter konstanten und gesteuerten Bedingungen geprüft und mit einem photo-elektrischen Kernzähler hoher Präzision, dem Standard der School of Cosmic Physics, verglichen. Die photographischen Aufzeichnungen der Nebelbildung in der zylindrischen Nebelkammer desVerzárschen Automaten, welche mit Galvanometern von 0.019 sec und 1.0 sec gemacht wurden, zeigen, dass ein Galvanometer mit einer Periode von 1 sec der raschen Bildung und Auflösung des Nebels nicht folgen kann, offenkundig durch die horizontale Anordnung des Nebelrohres und das Fehlen jeglicher Auskeidung mit feuchtem Isolationsmaterial bedingt.
DerVerzársche Automat ist ein ausgezeichnetes Gerät für die fortlaufende Registrierung der Kernzahl. Seine Eichkurve bedarf jedoch einer Abänderung, falls der photo-elektrische Kernzähler der School of Cosmic Physics in Dublin als Standard angenommen wird. Eine neue Eichkurve, welche sich auf die bisher in Dublin gemachten Vergleichungen stützt, wird reproduziert.
Similar content being viewed by others
References
Verzár F.:Kondensationskernzähler mit automatischer Registrierung; Archiv Meteorol., Geophysik etc. Serie A, Bd. V, 372–376 (1953).
Bitterli H. &Verzár F.:Erfahrungen mit dem automatischen Kondensationskernzähler; Ibidem, Bd. VI, 211–217 (1954).
Bider M. &Verzár F.:Kontinuierliche Messung atmosphärischer Kondensationskerne (Vorläufige Ergebnisse mit dem registrierenden Kernzähler in Basel); Geofisica pura e applicata, 26, 127–140 (1953).
Ackermann P., Bider M. &Verzár F.:Kontinuierliche Messungen von atmosphärischen Kondensationskernen; Ibidem 29, 167–200 (1954).Ackermann P.:Kondensationskernzählung in Payerne 1953; 168–177.Bider, M.:Ergebnisse der eineinhalbjährigen Registrierungen der Anzahl der Kondensationskerne in Basel; 178–191.Verzár F.:Kontinuierliche Zählung von atmosphärischen Kondensationskernen in St. Moritz; 192–200.
Bider M.:Ergebnisse der Registrierungen der Zahl der Kondensationskerne in Basel und seiner nächsten Umgebung; Ibidem 31, 147–161 (1955/II).
Verzár F.:Continuous record of atmospheric condensation nuclei and of their retention in the respiratory tract; Ibidem, 31, 183–190 (1955/II).
Pollak L. W., O'Connor T. C., Metnieks A. L. & Fürth R.,On the determination of the diffusion coefficient of condensation nuclei using the static and dynamic methods. Ibidem Geofisica pura e applicata 34 (1956).
Pollak L. W.:Improvements to the condensation nuclei counter with photographic recording and the frequency distribution of nuclei counts. Scientific Proc. Intern. Assoc. Meteorol., Tenth Gen. Assembly, Rome 1954; 374–381.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Metnieks, A.L. On F. Verzaŕ's photo-electric automatic nucleus counter. Geofisica Pura e Applicata 36, 41–48 (1957). https://doi.org/10.1007/BF01992991
Issue Date:
DOI: https://doi.org/10.1007/BF01992991