A capillary rheometer for dilute polymer solutions

  • Published:
Rheologica Acta Aims and scope Submit manuscript

Summary

A capillary rheometer developed by TNO enables, in principle, a reliable determination of the viscosity of dilute polymer solutions in the range of shear rates, where also measurements of the flow birefringence can be performed.

For Newtonian liquids, agreement with the results ofUbbelohde measurements was found.

For moderately concentrated solutions, however, a difference with the results ofUbbelohde measurements was observed, which may point to the presence of an elastic entrance effect in the latter measurements.

Zusammenfassung

Ein von TNO entwickeltes Kapillar-Rheometer ermöglicht im Prinzip eine zuverlässige Messung der Viskosität verdünnter Polymerlösungen bei Schergefällen, bei denen auch die Messung der Strömungsdoppelbrechung ausgeführt werden kann.

Für Newtonsche Flüssigkeiten wurde Übereinstimmung mit den Ergebnissen vonUbbelohde-Messungen gefunden.

Für mäßig konzentrierte Polymerlösungen wurde jedoch ein Unterschied gefunden, der mit dem Auftreten eines elastischen Eintrittseffektes bei denUbbelohde-Messungen zusammenhängen könnte.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Cragg, L. H. andH. van Oene, Can. J. Chem.39, 203 (1961).

    Google Scholar 

  2. Schurz, J., Rheol. Acta3, 43 (1963).

    Article  Google Scholar 

  3. van Wazer, J. R., J. W. Lyons, K. Y. Kim, andR. E. Colwell, Viscosity and Flow Measurement (New York 1963).

  4. Lodge, A. S., J. Sci. Instrum.37, 401 (1960).

    Article  Google Scholar 

  5. Oka, S., Chapt. 2 in:F. R. Eirich Ed., Rheology, Theory and Applications, Vol.3 (New York 1960).

  6. Zimm, B. H. andD. M. Crothers, Proc. Nat. Acad. Sci. U.S.48, 905 (1962).

    Google Scholar 

  7. Janeschitz-Kriegl, Rev. Sci. Instrum.31, 119 (1960).

    Article  Google Scholar 

  8. Janeschitz-Kriegl, H., andR. Nauta, J. Sci. Instrum.42, 829 (1965).

    Article  Google Scholar 

  9. Janeschitz-Kriegl, H. andW. Burchard, in the press.

  10. Janeschitz-Kriegl, H., Makromol. Chem.40, 140 (1960).

    Article  Google Scholar 

  11. Philippoff, W., J. Polymer Sci. Part C, No. 5, 1 (1964).

    Google Scholar 

  12. den Otter, J. L., Thesis, Leiden (1967).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Vorgetragen auf der Arbeitstagung [Messung und Interpretation von Fließkurven] der Sektion Rheologie des Vereins Österreichischer Chemiker am 17. November 1967 in Graz.

Rights and permissions