Dynamic mechanical testing of living skin

  • J. B. Finlay
  • I. A. Brown
Originals

Summary

There are no well established methods for the measurement of mechanical properties of living human skin. Thus the optimisation of the design in many of the procedures of reconstructive surgery is not achieved. There are also no objective methods for assessing the mechanical behaviour of skin and allied tissues during the treatment of rheumatic and other similar diseases. A method was developed to aid the study of these superficial tissues in the range of displacement and velocity encountered in life. The equipment incorporates a brushless d.c. torque motor with proportional plus derivative position feedback. This arrangement facilitates accurate analysis of the torque response of the human skin when subjected to various types of positioning input. Preliminary studies have been conducted using sinusoidal, trapezoidal and square wave displacement functions.

The mechanical phenomena encountered bothin vivo andin vitro on the same skin sample under identical surface boundary conditions illustrate changes in tissue behaviour occurring after excision. The associated microarchitectural changes have been examined using a scanning electron microscope.

Keywords

Torque Human Skin Torque Motor Surface Boundary Condition Position Feedback 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Zusammenfassung

Es gibt keine gut begründeten Methoden zur Messung der mechanischen Eigenschaften lebender menschlicher Haut. Daher ist das optimale Vorgehen bei vielen Verfahren der Wiederherstellungschirurgie noch nicht erreicht worden. Ebenso existieren keine objektiven Methoden zur Abschätzung des mechanischen Verhaltens von Haut und verwandten Geweben während der Behandlung von rheumatischen oder ähnlichen Erkrankungen. Es wurde eine Methode zur Untersuchung dieser Oberflächengewebe in Verschiebungs- und Geschwindigkeitsbereichen, wie sie im Leben vorkommen, entwickelt. Die Apparatur besteht aus einem bürstenlosen Gleichstrommotor konstanten Drehmoments mit proportionaler und geschwindigkeitsabhängiger Lagerrückführung. Dieser Aufbau erleichtert die genaue Analyse der Torsionskraftempfindlichkeit menschlicher Haut, wenn diese verschiedenen Arten von Lageeingaben ausgesetzt wird. Vorläufige Untersuchungen wurden unter Benutzung von sinus-, trapez- und rechteckförmigen Wegfunktionen durchgeführt.

Die mechanischen Erscheinungen, denen manin vivo undin vitro an der gleichen Hautprobe bei identischen Grenzflächeneigenschaften der Oberfläche begegnet, verdeutlichen die Veränderungen der Gewebeeigenschaften, die nach einer Exzision auftreten. Die begleitenden Veränderungen der Mikroarchitektur wurden mit Hilfe eines Rasterelektronenmikroskops untersucht.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Daly, C. H., The Biomechanical Characteristics of Human Skin, Ph. D. Thesis. University of Strathclyde (Glasgow 1966).Google Scholar
  2. Duggan, T. C., Dynamic Mechanical Testing of Living Tissue. Digest of the 7th International Conference on Medical and Biological Engineering, Stockholm, 27–1 (1967).Google Scholar
  3. Dupuytren, G., Traite théorique et Pratique des Blessures par Armes de Guerre. Paris1, 66 (1834).Google Scholar
  4. Evans, J. H., The Mechanical Characteristics of Human Skin. M. Sc. Thesis, University of Strathclyde Glasgow 1965).Google Scholar
  5. Evans, J. H. andW. W. Siesennop, Controlled Quasi-Static Testing of Human Skin in Vivo. Digest of the 7th International Conference on Medical and Biological Engineering, Stockholm 27–4 (1967).Google Scholar
  6. Gibson, T., H. Stark, andJ. H. Evans, J. Biomechanics2, 201–204 (1969).Google Scholar
  7. Kenedi, R. M., T. Gibson, andC. H. Daly, Bio-Engineering Studies of the Human Skin II. Biomechanics and Belated Bio-Engineering Topics. Proceedings of a Symposium held in Glasgow, September 1964 (London 1964).Google Scholar
  8. Langer, A. K., Zur Anatomie und Physiologie der Haut. 1. Über die Spaltbarkeit der Cutis. S. B. der Akad. in Wien44, 19–46 (1861).Google Scholar
  9. Ridge, M. D., The Rheology of Skin. Ph. D. Thesis, Dept. Medicine, University of Leeds (1964).Google Scholar
  10. Ridge, M. D. andV. Wright, An Engineering Study of Human Skin. Engineering, March. 363–364 (1965).Google Scholar
  11. Tomlinson, M., C. H. Daly, G. F. Odland, andJ. M. Short, In-Vivo Measurement of Skin Elasticity — A Clinical Evaluation. 3rd Annual Symposium, Bio-Engineering Program, University of Washington, 24th October (1969).Google Scholar
  12. Vlasblom, D. C., Skin Elasticity. Ph. D. Thesis, University of Utrecht, Netherlands (1967).Google Scholar

Copyright information

© Dr. Dietrich Steinkopff Verlag 1971

Authors and Affiliations

  • J. B. Finlay
    • 1
  • I. A. Brown
    • 1
  1. 1.Bio-engineering UnitUniversity of StrathclydeGlasgowScotland

Personalised recommendations