Abstract
The performance of a biphasic system for blood culture and a non-radiometric system using infrared spectroscopy was compared using 2,000 blood samples. The biphasic system detected bacteria or fungi in 237 blood cultures in 114 patients, while the non-radiometric system detected these microorganisms in only 186 blood cultures in 91 patients (p≤0.05). The speed with which the bacteria were detected and the rate of contamination were similar in the two systems. The capacity to detect different genera and species was similar except in the case ofBrucella spp., which the biphasic system detected in 28 blood cultures but the non-radiometric system in only 12 (p≤0.05).
Similar content being viewed by others
References
Kreger, B. E., Craven, D. E., McCabe, W. R. Gramnegative bacteremia. IV: Re-evaluation of clinical features and treatment in 612 patients. American Journal of Medicine 1980, 68: 345–354.
Weinstein, M. P., Murphy, J. R., Reller, R. B., Lichtenstein, K. A. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. II: Clinical observations, with special reference to factors influencing prognosis. Reviews of Infectious Diseases 1983, 5: 54–70.
Henry, N. K., Grewell, C. M., Limans, C. A., Washington, J. A. Comparison of the Roche Septi-Check blood culture bottle with a brain-heart infusion biphasic medium bottle and a tryptic soy broth bottle. Journal of Clinical Microbiology 1984, 19: 315–317.
Pfaller, M. A., Sibley, T. K., Westfall, L. M., Hoppe-Bauer, J. E., Keating, M. A., Murray, P. R. Clinical laboratory comparison of a slide broth culture system with a conventional broth system. Journal of Clinical Microbiology 1982, 16: 525–530.
Smith, J. A., Roberts, F. J., Ngui-Yen, J. Comparison of a radiometric and a broth-slide system for aerobic blood culture. Journal of Clinical Microbiology 1983, 18: 217–218.
Caplan, L. M., Merz, W. G. Evaluation of two commercially prepared biphasic media for recovery of fungi from blood. Journal of Clinical Microbiology 1978, 8: 469–470.
Kiehn, T. E., Capitolo, C., Mayo, J. B., Armstrong, D. Comparative recovery of fungi from biphasic and conventional blood culture media. Journal of Clinical Microbiology 1981, 14: 681–683.
Roberts, G. D., Washington, J. A. Detection of fungi in blood culture. Journal of Clinical Microbiology 1975, 1: 309–310.
Hall, M., Mueske, C. A., Illstrup, D. M., Washington, J. A. Evaluation of a biphasic medium for blood cultures. Journal of Clinical Microbiology 1979, 10: 673–676.
Bryan, L. E. Comparison of a slide blood culture system with a supplemented peptone blood culture method. Journal of Clinical Microbiology 1981, 14: 389–392.
Weinstein, M. P., Reller, L. B., Mirret, S., Stratton, C. W., Reimer, L. G., Wang Wen-Lan, L. Controlled evaluation of the agar-slide and radiometric blood culture system for the detection of bacteremia and fungemia. Journal of Clinical Microbiology 1986, 23: 221–225.
Tilton, R. C. The laboratory approach to the detection of bacteremia. Annual Reviews of Microbiology 1982, 36: 467–493.
Jungkind, D., Millan, J., Allen, S., Dyke, J., Hill, E. Clinical comparison of a new automated infrared blood culture system with the 460 system. Journal of Clinical Microbiology 1986, 23: 262–266.
Ariza, J. Brucelosis 1985. Medicina Clinica 1986, 86: 60–62.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rodriguez, J.A.G., Sanchez, J.E.G., Bellido, J.L.M. et al. Comparison of a biphasic system and a non-radiometric system for blood culture. Eur. J. Clin. Microbiol. Infect. Dis. 7, 666–668 (1988). https://doi.org/10.1007/BF01964249
Issue Date:
DOI: https://doi.org/10.1007/BF01964249