Abstract
In order to determine fluctuations in virus antibody levels, blood specimens were collected weekly from 13 healthy adults during a nine-week period and tested by enzyme immunoassay for IgG antibodies against measles, rubella and cytomegalovirus. In 29 of 35 subject-titer pairs the difference between the highest and lowest titers observed was less than twofold, in five cases it was between twofold and threefold, and in one case it was 3.3-fold. These differences were higher than those caused by intra-assay variation alone. The results indicate that some physiological fluctuations seem to occur in the antibody levels of healthy individuals. Although the fluctuations are usually small, care should be taken if titer increases less than fourfold are used as a criterion to indicate recent infection.
Similar content being viewed by others
References
Julkunen, I., Kleemola, M., Hovi, T. Serological diagnosis of influenza A and B infections by enzyme immunoassay. Comparison with complement fixation test. Journal of Virological Methods 1984, 9: 7–14.
Waner, J. L., Weller, T. H., Kevy, S. V. Patterns of cytomegalovirus complement-fixing antibody activity: a longitudinal study of blood donors. Journal of Infectious Diseases 1973, 127: 538–543.
Lehtonen, O.-P., Meurman, O. An ELISA for the estimation of high avidity and total specific IgG and IgM antibodies to rubella virus. Journal of Virological Methods 1982, 5: 1–10.
Meurman, O., Ziola, B. IgM-class rheumatoid factor interference in the solid-phase radioimmunoassay of rubella specific IgM antibodies. Journal of Clinical Pathology 1978, 31: 483–487.
Ziola, B., Salmi, A., Panelius, M., Halonen, P., Friis, B. Measles virus-specific IgM antibodies and IgM-class rheumatoid factor in serum and cerebrospinal fluid of subacute sclerosing panencephalitis patients. Clinical Immunology and Immunopathology 1979, 13: 462–474.
Sundqvist, V. A., Wahren, B. An interchangeable ELISA for cytomegalovirus antigen and antibody. Journal of Virological Methods 1981, 2: 301–312.
Burrows, P. M., Scott, S. W., Barnerr, O. W., McLaughlin, M. R. Use of experimental designs with quantitative ELISA. Journal of Virological Methods 1984, 8: 207–216.
Chessum, B. S., Denmark, J. R. Inconstant ELISA. Lancet 1978, i: 161.
Cremer, N. E., Devlin, V. L., Riggs, J. L., Hagens, S. J. Anomalous antibody responses in viral infection: Specific stimulation or polyclonal activation? Journal of Clinical Microbiology 1984, 20: 468–472.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Meurman, O., Lehtonen, O.P. Fluctuation of virus antibody levels in healthy adults. Eur. J. Clin. Microbiol. Infect. Dis. 7, 656–658 (1988). https://doi.org/10.1007/BF01964245
Issue Date:
DOI: https://doi.org/10.1007/BF01964245