Experientia

, Volume 33, Issue 4, pp 553–554 | Cite as

Intracellular pH of Limulus ventral photoreceptor measured with a double-barrelled pH microelectrode

  • S. Levy
  • J. A. Coles
Pro Experimentis

Summary

The intracellular pH of the Limulus ventral photoreceptor was measured with a double-barrelled pH microelectrode and found to be 7.01±0.04 SE (n=9).

Keywords

Ventral Photoreceptor Limulus Ventral Photoreceptor 

References

  1. 3.
    J. E. Lisman and J. E. Brown, J. gen. Physiol.66, 473 (1975).PubMedGoogle Scholar
  2. 4.
    J. A. Coles and J. E. Brown, Biochem. biophys. Acta436, 140 (1976).PubMedGoogle Scholar
  3. 5.
    L. H. Pinto, J. E. Brown and P. K. Brown, Biophys. J.16, 34a (1976).Google Scholar
  4. 6.
    L. R. Puccaco and N. W. Carter, Analyt. Biochem.73, 501 (1976).PubMedGoogle Scholar
  5. 7.
    J. E. Lisman and J. E. Brown, J. gen. Physiol.59, 701 (1972).PubMedGoogle Scholar
  6. 8.
    D. A. Baylor, M. G. F. Fuortes and P. M. O'Bryan, J. Physiol.214, 265 (1971).PubMedGoogle Scholar

Copyright information

© Birkhäuser Verlag 1977

Authors and Affiliations

  • S. Levy
    • 1
    • 2
  • J. A. Coles
    • 2
  1. 1.Experimental Ophthalmology LaboratoryUniversity of GenevaGeneva 4(Switzerland)
  2. 2.Department of PhysiologyUniversity of Geneva, Medical SchoolGeneva(Switzerland)

Personalised recommendations