Skip to main content
Log in

Kinetic measurements on polymers — Applications and limits

  • Published:
Journal of thermal analysis Aims and scope Submit manuscript

Abstract

A modern kinetic evaluation method for nonisothermal reactions measured with TG or DSC is presented. The obtained kinetic data are the basis for computation of a reaction process under any condition, e.g. isothermal or adiabatic.

The measurements were performed on a Mettler TA3OOO system with built-in evaluation software. Mainly the following reactions are discussed: polyaddition of an epoxy premix and pyrolysis of polystyrene.

To judge the reliability of the results, 4 check procedures are recommended.

Zusammenfassung

Es wird eine moderne kinetische Auswertungsmethode für durch TG oder DSC verfolgte nichtisotherme Reaktionen vorgestellt. Die erhaltenen kinetischen Daten stellen die Basis der Berechnung der Reaktionsprozesse unter jeder, z.B. isothermer oder isobarer Bedienung dar. Die Messungen wurden mit dem Mettler-System TA3000 mit Auswertungs-software ausgeführt. In erster Linie werden die folgenden Reaktionen diskutiert: Polyaddition eines Epoxy-Vorgemisches, Pyrolyse von Polystyrol. Zur Beurteilung der Zuverlässigkeit der Ergebnisse werden 4 Testverfahren empfohlen.

Резюме

Представлен совреме нный метод оценки кинетики неизотерми ческих реакций, измеренной м етодами ТГ и ДСК. Получ енные кинетические данные являются основой для компьютеризации реа кционного процесса в каком-либо режиме, как например, изотермическом или адиабатическом. И змерения были провед ены на Меттлер TA 3000 системе с математич еским обеспечением д ля проведения такой оценки. Обсужде ны главным образом ре акции полиприсоединения какого-либо начально го эпоксида и пиролиз полистирола. Для оценки надежност и получаемых результ атов рекомендуется четыр е способа проверки.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H. Wyden andG. Widmann, Experientia Supplementum, Vol.37. /E. Marti et al., ed./ Birkhäuser, Basel, 1979, p.284.

    Google Scholar 

  2. J.H. Flynn, Thermal Analysis in Polymer Characterization /E. Turi ed./ Heyden & Son, Philadelphia 1981, p.43.

    Google Scholar 

  3. V. Schlichenmaier andG. Widmann, Thermochim. Acta, 21/1977/ 39.

    Google Scholar 

  4. R.B. Prime, Thermal Characterization of Polymeric Materials /E. Turi ed./ Academic Press, New York 1981, p.533.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Widmann, G. Kinetic measurements on polymers — Applications and limits. Journal of Thermal Analysis 25, 45–55 (1982). https://doi.org/10.1007/BF01913053

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01913053

Keywords