Skip to main content
Log in

Pulsatile flow in arteries with external restraint of visco-elastic tissue

  • Published:
Applied Mathematics and Mechanics Aims and scope Submit manuscript

Abstract

The presence of a longitudinal constraint must be conceived physiologically as due largely to the connective tissue attachments on the outside of the artery. Living tissues are viscoelastic bodies. In order to analyse the effect of external viscoelastic tissue to pulsatile flow in arteries, in this paper the external connective tissue of artery will be considered as a Voigt visco-elastic body, and the expressions of pulse wave velocity and the velocity of pulsatile flow will be found by the velocity of pulsatile flow will be found by the blood motion equations (Navier-Stokes equation) as well as wall motion equations (Lamb equation). The results of free elastic tube[4] and those of external elastic restraint[6] by Womersley can be considered as a particular case and can be covered in this paper.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Karreman, G., Soem contribution to the mathematical biology or blood circulation: Reflections of pressure waves in the artery system, Bull. Math. Biophys., 14, (1952), 327–350.

    Google Scholar 

  2. Morgan, G. W. and J. P. Kiely, Wave propagation in a viscous liquid contained in a flexible tube, J. Acoust. Soc. Amer., 26, (1954), 323–328.

    Google Scholar 

  3. Womersley, J. R., Oscillatory motion of a viscous liquid in a thin-walled elastic tube, I. The approximation for long waves, Phil. Mag., 46, (1955), 199–221.

    Google Scholar 

  4. Womersley, J. R., Method for the calculation of velocity: rate of flow and viscous drag in arteries when the pressure gradient is known, J. Physiol., 127, (1955), 553–563.

    Google Scholar 

  5. McDonald, D. A., Blood Flow in Arteries, Edward Arnold (Publishers) Ltd, (1974).

  6. Womersley, J. R., Oscillatory flow in arteries: the constrained elastic tube as a model of arterial flow and pulse transmission, Phys. in Med. Biol., 2, (1957), 178–187.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Communicated by Ouyang Chang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhao-rong, L. Pulsatile flow in arteries with external restraint of visco-elastic tissue. Appl Math Mech 5, 1485–1491 (1984). https://doi.org/10.1007/BF01910439

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01910439

Keywords

Navigation