Skip to main content
Log in

The microsphere method facilitates statistical assessment of regional blood flow

  • Original Contributions
  • Published:
Basic Research in Cardiology Aims and scope Submit manuscript

Summary

When microspheres are injected into the circulation, they are trapped in the arteriolar or capillary system within various organs. It has been confirmed in animal experiments that the number of microspheres in a myocardial sample approximately follows a Poisson distribution, under adequate experimental conditions. On the basis of this result, we arrived at the following hypothesis:

When regional blood flow is measured under a steady state by the reference sample method, the 95% relative error can be approximated by\( \pm 196\sqrt {1/v + 1w} \), wherev andw represent the number of microspheres in blood sample and myocardial sample, respectively. The equation is valid ifv andw are greater than 400 and 49, respectively.

We obtained an expression of the relation among the percent of increase or decrease in regional blood flow being verified, the probability of increase or decrease, as a statistically significant variation and the number of microspheres in a myocardial sample. An investigator can work out an approximate experimental design using this expression. For instance, when the increase in regional blood flow required for verification is expected to be 20% and he wants this increase to be verified by 90%-probability and as a statistically significant increase, he can predict from this expression that the number of microspheres in a myocardial sample should be 472 and 567 before and after the experimental intervention on the coronary circulation, respectively. The expression is useful as index for experiments involving use of the microsphere method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Buckberg GD, Luck JC, Payne DB, Hoffman JIE, Archie JP, Fixler DE (1971) Some sourees of error in measuring regional blood flow with radioactive microspheres. J Appl Physiol 31 598–604

    PubMed  Google Scholar 

  2. Cobb JR, Bache RJ, Greenfield JC Jr (1974) Regional myocardial blood flow in awake dogs. J Clin Invest 53:1618–1625

    PubMed  Google Scholar 

  3. Falsetti HL, Carrol RJ, Marcus ML (1975) Temporal heterogeneity of myocardial blood flow in anaesthetized dogs. Circulation 52:848–853

    PubMed  Google Scholar 

  4. Fung Y (1973) Stochastic flow in capillary blood vessels. Microvasc Res 5:34–48

    PubMed  Google Scholar 

  5. Heymann MA, Payne BD, Hoffman JIE, Rudolph AM (1977) Blood flow measurements with radionuclide-labeled particles. Pro Cardiovasc Dis 20:55–79

    Google Scholar 

  6. Johnson NL, Kotz S (1969) Discrete distributions. John Wiley & Sons Inc, pp 216–221

  7. Kendall MG, Stuart A (1980) The advanced theory of statistics, Vol 2, 4th Edition. Griffin, London, pp 449–450

    Google Scholar 

  8. Nakamura T (1980) On the moment of positively truncated normal distribution. J Jap Stat Soc 10:139–144

    Google Scholar 

  9. Nose Y (1978) Independent measurement of the distribution of blood flow from the left circumflex coronary artery and the other coronary arteries. Fukuoka Acta Medica 69:268–287

    Google Scholar 

  10. Phibbs RH, Dong L (1970) Nonuniform distribution of microspheres in blood flowing through a medium-size artery. Can J Physiol Pharmacol 48:415–421

    PubMed  Google Scholar 

  11. Rao CR (1973) Linear statistical inference and its applications. John Wiley & Sons Inc, p 357

  12. Rao CR (1973) Linear statistical inference and its applications. John Wiley & Sons Inc, pp 385–387

  13. Snedecor G, Cochran W (1967) Statistical Methods. 6th Edition, Ames, Iowa, USA, The Iowa State University Press, pp 240–242

    Google Scholar 

  14. Snedecor G, Cochran W (1967) Statistical Methods. 6th Edition, Ames, Iowa, USA, The Iowa State University Press, pp 86–87

    Google Scholar 

  15. Utley J, Carlson EL, Hoffman JIE, Martinez HM, Buckberg GD (1974) Total and regional myocardial blood flow measurements with 25 μ, 15 μ, 9 μ and filtered 1–10 μ diameter microspheres and antipyrine in dogs and sheep. Circ Res 34:391–405

    PubMed  Google Scholar 

  16. Yipintsoi T, Dobbs WA Jr, Scanlon PD, Knopp TJ, Bassingthwaighte JB (1973) Regional distribution of diffusible tracers and carbonized microspheres in the left ventricle of isolated dog hearts. Circ Res 33:573–587

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported in part by Grants No. 021519, 121727, 220926, 320227 and 921811 in aid for Fundamental Scientific Research from the Ministry of Education, Japan

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nose, Y., Nakamura, T. & Nakamura, M. The microsphere method facilitates statistical assessment of regional blood flow. Basic Res Cardiol 80, 417–429 (1985). https://doi.org/10.1007/BF01908186

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01908186

Key words

Navigation