Abstract
In a field widened interferometer, the optical path difference changes by less than one wavelength over a field of view of ten degrees or more, making it particularly suitable for imaging. The Wide Angle Michelson Interferometer (WAMI) is a conceptually simple device, constructed for a single path difference, that generates a cosinusoidal output whose phase yields the Doppler velocity, and whose modulation depth gives the temperature. In practice, such a field widened configuration involves refractive material, but by careful selection the assembly can be compensated for thermal and wavelength variations of the glass constants. In this mode the WAMI provides an extremely efficient way of extracting Doppler information from a simple known spectrum, such as an isolated Gaussian line, or even a doublet. However, when additional spectral information is required, it is necessary to combine the WAMI with a low resolution Fabry-Perot etalon. Two spaceflight imaging WAMIs now under construction are described; the space shuttle WAMDII, and WINDII, which will fly on the Upper Atmosphere Research Satellite.
Similar content being viewed by others
References
Hernandez, G.:Fabry-Perot Interferometers, Cambridge University Press, Cambridge, England.
Hilliard, R. L. and Shepherd, G. G.: 1966a, ‘Wide-Angle Michelson Interferometer for Measuring Doppler Line Widths’,J. Opt. Soc. Am. 56, 362.
Hilliard, R. L. and Shepherd, G. G.: 1966b, ‘Upper Atmospheric Temperatures from Doppler Line Widths’,Planet. Space Sci. 14, 383.
Shepherd, G. G., Gault, W. A., Koehler, R. A., McConnell, J. C., Paulson, K. V., Llewellyn, E. J., Anger, C. D., Cogger, L. L., Haslett, J. W., Moorcroft, D. R., and Gattinger, R. L.: 1984, Optical Doppler Imaging of the Aurora Borealis,Geophys. Res. Lett. 11, 1003.
Shepherd, G. G., Gault, W. A., Miller, D. W., Pasturczyk, Z., Johnston, S. F., Kosteniuk, P. R., Haslett, J. W., Kendall, D. J. W., and Wimperis, J. R.: 1985, WAMDII: Wide-Angle Michelson Doppler Imaging Interferometer for Spacelab,Appl. Opt. 24, 1571.
Thuillier, G. and Shepherd, G. G.: 1985, ‘Fully Compensated Michelson Interferometer of Fixed Path Difference’,Appl. Opt. 24, 1599.
Ward, W. E., Pasturczyk, Z., Gault, W. A., and Shepherd, G. G.: 1985, ‘Multiple Reflections in a Wide-Angle Michelson Interferometer’,Appl. Opt. 24, 1589.
Yee, E., Paulson, K. V., and Shepherd, G. G.: 1987, ‘Minimum Cross-Entropy Inversion of Satellite Photometer Data’,Appl. Opt. (submitted).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Shepherd, G.G. Optical Soppler imaging with field-widened Michelson interferometers. Surv Geophys 9, 185–195 (1987). https://doi.org/10.1007/BF01904122
Issue Date:
DOI: https://doi.org/10.1007/BF01904122