Summary
A new method for accurate positioning of the tip of the atrial catheter in the middle of the right atrium in ventriculoatrial shunt operations is described. The correct length of the catheter is obtained from a consideration of the surface anatomy of the heart in each patient. The position of the tip of the catheter was checked by postoperative chest radiographs in posteroanterior and lateral views. The technique was used in 50 cases of hydrocephalus in which ventriculoatrial shunts were performed. The approach is simple and reliable, and is useful not only for elective operations but also in emergency situations where specialized monitoring equipment is not readily available.
Similar content being viewed by others
References
Bouchard, G., Dieckmann, G., Ganglberger, J., Gattner-Ponitz, M., Hemmer, R., Horstmann, W., Luthardt, Th., Mundinger, F., Orgass, B., Scholtz, W., Struck, G., Tiling, E., Erfahrungen mit der modernen operativen Hydrozephalusbehandlung. Arch. Kinderheilk.51 (1964), 1–64.
Elkins, C. W., Fonseca, J. E., Ventriculovenous anastomosis in obstructive and acquired communicating hydrocephalus. J. Neurosurg.18 (1961), 139–144.
Gurdjian, E. S., Thomas, L. M., Operative Neurosurgery, pp. 208, 3rd Ed. Baltimore: Williams & Wilkins. 1970.
Jackson, J. D., 1965, Ventriculo-atrial shunt in the management of Hydrocephalus. Southern Med. J.58 (1965), 405.
Järpe, S., Hebbe, B., Jeppsson, S., A new method for accurate placement of the Holter Caval catheter in hydrocephalus surgery. Acta Chir. Scand.135 (1969), 121–125.
Kurlander, G. J., Chna, G. T., Roentgenology of ventriculo-atrial shunts for the treatment of hydrocephalus. Amer. J. Roentgenol.101 (1967), 157–167.
Lepoire, J., Lapras, C., Traitement de l'Hydrocéphalique non tumorale du nourrisson par la dérivation ventriculo-atriale. Neuro-Chirurgie13 (1967), 211–342.
Lombard, G. F., Micheletti, P. C., Morgando, E., Contributo dell' electrocardiogramma al l'Intervento di Spitz-Holter. Min. Neurochir.7 (1963), 66–67.
Mark, V. H., Sweet, W. H., Ventriculo-atriostomy; a technical note: The accurate placement of the distal end of the shunt into the right atrium without X-ray control. Neurochirurgia (Stuttgart)3 (1960), 115–120.
McLaurin, R. L., Glass, I. H., Kaplan, S., Ventriculo-atrial shunt for hydrocephalus. Electrocardiographic control for accurate placement. Amer. J. Dis. Child.205 (1963), 216–218.
Rickham, P. P., Hydrocephalus. In Neonatal surgery. pp. 472, ed. by P. P. Rickham and J. H. Johnston. London: Butterworth. 1969.
Robertson, J. T., Schick, R. W., Morgan, E., Matson, D. D., Accurate placement of ventriculo-atrial shunt for hydrocephalus under electrocardiographic control. J. Neurosurg.18 (1961), 255–257.
Robinson, J. O., Rawlings' Landmarks and surface markings of the human body. pp. 51, 9th ed. London: H. K. Lewis & Co. Ltd. 1953.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rohatgi, M., Goulatia, R.K. A new technique for accurate placing of the tip of the atrial catheter in ventriculo-atrial shunt operations for hydrocephalus. Acta neurochir 33, 167–172 (1976). https://doi.org/10.1007/BF01886667
Issue Date:
DOI: https://doi.org/10.1007/BF01886667