Advertisement

Research in Experimental Medicine

, Volume 186, Issue 1, pp 15–19 | Cite as

Uterine fibrinolysis and unilateral insertion of devices in rats

  • A. Kjældgaard
Original Papers

Summary

The validity of a frequently used experimental model for evaluating the effect of different intrauterine devices (IUDs) on uterine fibrinolysis in rodents was investigated in 42 rats. In this model, an IUD is inserted into one horn by a surgical procedure including laparotomy and uterotomy, while the other empty horn is used as a control. In the present investigation, the fibrinolytic activity in different parts of the IUD-containing and control horn was related to the localization of the IUD. The fibrinolytic activity as determined according to Todd's histochemical fibrin slide method was significantly increased in the endometrium in direct contact with the IUD as well as in the uterine segment opposite to the IUD. The enhancement of fibrinolysis in the opposite segment of the control horn was independent of the localization of the IUD, suggesting that neurogenic mechanisms may underlie the stimulation of uterine fibrinolysis in the empty horn. It was concluded that this experimental model is less suitable for evaluating the effect of IUDs on uterine fibrinolysis, since the presence of an IUD in one uterine horn also influences the fibrinolytic activity of the other horn.

Key words

Fibrinolysis Uterus Intrauterine device Rats 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Rybo G (1978) The IUD and endometrial bleeding. J Reprod Med 20:175–182PubMedGoogle Scholar
  2. 2.
    Goh TH, Hriharan M, Chan GL (1984) Anaemia and menstrual blood loss studies in women using Multiload Cu250 and Progestasert IUDs. Contraception 20:359–366Google Scholar
  3. 3.
    Liedholm P, Srivasta K, Wingerup L, Åstedt B (1983) Higher fibrinolytic activity in human endometrium in direct contact with an IUD. Acta Obstet Gynecol Scand 62:169–170PubMedGoogle Scholar
  4. 4.
    Larsson B, Liedholm P, Åstedt B (1975) Effect of copper and plastic intra-uterine devices on the fibrinolytic activity of the endometrium in the rat. Int J Fertil 20:145–150PubMedGoogle Scholar
  5. 5.
    Ledger WJ, Virkar KD, Irvin LA (1966) Effect of a plastic intrauterine device upon implantation in the rabbit. Obstet Gynecol 28:521–525PubMedGoogle Scholar
  6. 6.
    Liedholm P, Sjöberg N-O (1977) Fibrinolytic activity in the rabbit uterus and its fluid with and without copper IUD. Contraception 15:215–224PubMedGoogle Scholar
  7. 7.
    Liedholm P, Sjöberg N-O (1979) Differences in effect of copper and Progestasert IUDs on fibrinolytic activity of the endometrium in the rabbit. Contraception 19:443–448PubMedGoogle Scholar
  8. 8.
    Kjældgaard A, Anker C, Larsson B (1985) Inhibitory effect of progesterone on IUD-induced activation of fibrinolysis in the rat uterus. Contraceptive Delivery Systems (in press)Google Scholar
  9. 9.
    Kjældgaard A, Anker C, Larsson B (1985) Decreased fibrinolytic activity in the rat uterus after laparotomy. Res Exp Med (Berl) 185:277–281Google Scholar
  10. 10.
    Kjældgaard A, Anker C, Larsson B (1985) Progesterone-releasing device and uterine fibrinolysis: comparison of two experimental models. Contraceptive Delivery Systems (in press)Google Scholar
  11. 11.
    Todd AS (1959) Histological localisation of fibrolysin activator. J Pathol Bacteriol 78:281–283PubMedGoogle Scholar
  12. 12.
    Pandolfi M (1972) Histochemistry and assay of plasminogen activator(s). End J Clin Biol Res 17:254–260Google Scholar
  13. 13.
    Emesis JJ (1983) Perfused rat hindlegs. A model to study plasminogen activator release. Tromb Res 30:195–203Google Scholar
  14. 14.
    Nilsson IM (1978) Effect of drugs on activator synthesis and release. In: Davidson JF, Rowan RM, Samama MM, Desnoyers PC (eds) Progress in chemical fibrinolysis and thrombolysis, vol 3. Raven Press, New York, pp 77–89Google Scholar
  15. 15.
    Dadelszen P, Hurst PR, Peplow PV (1982) Effect of indomethacin incorporation on the retention of silastic intrauterine devices in the rat. Contraception 26:159–168PubMedGoogle Scholar

Copyright information

© Springer-Verlag 1986

Authors and Affiliations

  • A. Kjældgaard
    • 1
  1. 1.Dept. of Obstetrics and Gynecology, Karolinska InstitutetHuddinge University HospitalHuddingeSweden

Personalised recommendations