Skip to main content
Log in

Das Göttinger Miniaturschwein als Versuchstier

5. Mitteilung: Das Herzminutenvolumen, seine prozentuale Verteilung auf den Organismus und die effektive Organdurchblutung

The Göttinger minipig as a laboratory animal

5. Communication: Cardiac Output, Its Regional Distribution and Organ Blood Flow

  • Original Works / Originalarbeiten
  • Published:
Research in Experimental Medicine

Summary

In 16 juvenile minipigs weighing 3.08 kg an average cardiac output of 23 ml/100 g body weight was measured with the dye-dilution method. The microsphere technique was used to assess distribution of cardiac output and organ blood flow. In 12 adult minipigs with a mean body weight of 21.5 kg the cardiac output of 14 ml/100 g body weight was measured with an electromagnetic flowmeter. The values of total systemic and organic blood flow correlated well with those of man and partly with those of other laboratory animals.

Zusammenfassung

Bei 16 juvenilen Miniaturschweinen mit einem durchschnittlichen Körpergewicht von 3,08 kg wurde ein Herzminutenvolumen von 23 ml/100 g Körpergewicht mit der Farbstoffverdünnungsmethode gemessen; die prozentuale Verteilung des Herzzeitvolumens und die effektive Organdurchblutung wurden mit der Mikrosphärenmethode ermittelt. Bei 12 adulten Miniaturschweinen mit durchschnittlich 21,5 kg Körpergewicht wurde ein Herzminutenvolumen von 14 ml/100 g elektromagnetisch bestimmt. Die Werte für das Herzzeitvolumen und dessen prozentuale Verteilung stimmen mit denen des Menschen gut, mit denen anderer Laboratoriumstiere (Hund, Affe) nur zum Teil überein.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Abel, F. L.: Cardiac output during shock: indicator-dilution versus electromagnetic flowmeter methods. Circulatory Shock2, 239–247 (1975)

    Google Scholar 

  2. Altmann, Ph., Dittmer, D. S.: Respiration and Circulation. Fed. Ann. Soc. Exp. Biol. (1971)

  3. Becker, M., Stauffer, U. G.: The role of general anesthesia in experimental surgery on young minipigs. J. Ped. Surg.9, 515–519 (1974)

    Google Scholar 

  4. Becker, M., Beglinger, R., Stauffer, U. G.: Das Göttinger Miniaturschwein als Versuchstier. 2. Mitteilung: Blutbild, Serumelektrolyte, Wasserstoffionenkonzentration und Blutgase. Res. Exp. Med.167, 185–192 (1976)

    Google Scholar 

  5. Beglinger, R., Becker, M., Eggenberger, E., Lombard, C.: Das Göttinger Miniaturschwein als Versuchstier. 1. Mitteilung: Literaturübersicht, Zucht und Haltung, Kreislaufparameter. Res. Exp. Med.165, 251–263 (1975)

    Google Scholar 

  6. Behrman, R. E., Lees, M. H.: Organ blood flows of the fetal, newborn and adult rhesus monkey. Biol. Neonate18, 330–340 (1971)

    PubMed  Google Scholar 

  7. Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffmann, J. I. E., Archie, J. P., Fixler, D. E.: Some sources of error in measuring regional blood flow with radioactive microspheres. J. Appl. Physiol.31, 598–604 (1971)

    PubMed  Google Scholar 

  8. Forsyth, R. P., Nies, A. S., Wyler, F., Neutze, J., Melmon, K. L.: Normal distribution of cardiac output in the unanesthetized, restrained rhesus monkey. J. Appl. Physiol.25, 736–741 (1968)

    PubMed  Google Scholar 

  9. Meisner, H., Messmer, K.: Die elektromagnetische Messung der Blutströmung. Z. Kreisl.-Forsch.58, 307–319 (1969)

    Google Scholar 

  10. Neutze, J. M., Wyler, F., Rudolph, A. M.: Use of radioactive microspheres to assess distribution of cardiac output in rabbits. Am. J. Physiol.215, 486–495 (1968)

    PubMed  Google Scholar 

  11. Rudolph, A. M., Heymann, M. A.: The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circulat. Res.21, 163–184 (1967)

    PubMed  Google Scholar 

  12. Rudolph, A. M.: Congenital disease of the heart, pp. 17–28. Chicago: Year Book Medical Publ. 1974

    Google Scholar 

  13. Sawyer, D. C., Lumb, W. V.: Halothane anesthesia in miniature swine. Anesth. Analg.49, 616–619 (1970)

    PubMed  Google Scholar 

  14. Wade, O. W., Bishops, T. M.: Cardiac output and regional blood flow. Oxford: Blackwell 1962

    Google Scholar 

  15. Wyler, F., Forsyth, R. P., Nies, A. S., Neutze, J. M., Melmon, K. L.: Endotoxin-induced regional circulatory changes in the unanesthetized monkey. Circulat. Res.24, 777–786 (1969)

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Mit Unterstützung des Schweiz. Nationalfonds, Kredit Nr. 3.2760.74 und 4483.3

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wyler, F., Käslin, M., Hof, R. et al. Das Göttinger Miniaturschwein als Versuchstier. Res. Exp. Med. 175, 31–36 (1979). https://doi.org/10.1007/BF01851231

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01851231

Key words

Schlüsselwörter

Navigation