Clinical experience with the MLCu250 IUD (eight-year results)

Abstract

Between 1977 and 1981, 1561 MLCu250 standard model IUDs were inserted at the Family Planning Center, Department of Obstetrics and Gynecology, University Medical School of Debrecen, Hungary. The majority were in the first (61.3%) and second (32.2%) segment and only a few were in the third (5.4%), fourth (1.0%) or fifth (0.1%) segment.

Insertions were performed in the postmenstrual, postabortal, postpartal and postpuerperal periods. This report evaluates the data for interval insertions only, representing a total of 1457 cases and 65762 woman-months of use during an 8-year follow-up period. Using Tietze's life table technique, cumulative and yearly specific termination rates have been calculated. Fifty per cent of the devices were in place after 5 years of use, and 27.8% of the patients wore the IUD even at the end of the eighth year after insertion. The pertinent termination rate (pregnancy, expulsion, removal for bleeding/pain and for other medical reasons together) was 56.8 in the 96th ordinal month. These findings prove the good over-all performance of the MLCu250 IUD and demonstrate a longer life span for the device than was previously expected.

Resumé

Entre 1977 et 1981, le Centre de Planning Familial du Service d'Obstétrique et de Gynécologie de la Faculté de Médecine de l'Université de Debrecen en Hongrie a mis en place 1561 stérilets MLCu250 standards, dont la plupart dans le premier (61,3%) et le second (32,2%) segments, et quelques-uns seulement dans les troisième (5,4%), quatrième (1%) et cinquième (0,1%) segments.

Les stérilets ont été mis en place durant les périodes post-menstruelle, post-abortive, post-natale et post-puérpérale. Dans ce rapport, l'auteur ńa évalué que les résultats relatifs aux intervalles d'utilisation, ce qui correspond au total à 1457 cas et 65762 mois d'utilisation par les femmes concernées, dans le cadre d'une période de suivi de huit ans. Les taux de terminaison d'emploi cumulatifs et annuels spécifiques ont été calculés par la technique des tables de Tietze (tables de survie). Après cinq ans d'emploi, cinquante pour cent des stérilets étaient encore en place et, même à la fin de la huitième année, 27,8% des patientes portaient toujours leur stérilet. Le taux de terminaisons pertinent a été de 56,8 pendant le 96 ème mois ordinal. Ces résultats prouvent que la performance d'ensemble des stérilets MLCu250 est bonne, et démontrent que leur durabilité excède les prévisions.

Resumen

Entre 1977 y 1981 se colocaron 1561 DIU MLCu250 Modelo estánder en el Centro de Planificación Familiar del Departamento de Obstetricia y Ginecología de la Escuela Medica de la Universidad de Debrecen, Hungria. La mayoría fueron insertados en el primer (61,3%) y segundo grupo (32,2%) y, solamente, unos pocos fueron insertados en el tercer (5,4%), cuarto (1,0%) o quinto grupos. Se efectuaron inserciones en períodos post-menstruales, post-aborto, post-parto y post-puerperal. Este informe evalúa solamente los datos de inserciones de intervalo que representan un total de 1457 casos y 65762 mujeres-ciclos de uso durante ocho años de seguimiento. Usando la técnica de tabla de vida de Tietze, se calcularon las tasas cumulativas anuales específicas de terminación. Cincuenta por ciento de los dispositivos permanecian en su sitio despues de cinco años de uso y 27,8% de las pacientes mantuvieron el DIU hasta el final del octavo año. La tasa pertinente de terminación fue de 56,8 en el 96 mes. Estos resultados indican el buen desempeño general del DIU MLCu250 y señalan un período de vida para el dispositivo más largo que el esperado.

This is a preview of subscription content, access via your institution.

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Batár, I. Clinical experience with the MLCu250 IUD (eight-year results). Adv Contracept 1, 329–335 (1985). https://doi.org/10.1007/BF01849308

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01849308

Keywords

  • Life Span
  • Family Planning
  • Termination Rate
  • Life Table
  • Specific Termination