Skip to main content
Log in

Color and pulsed Doppler studies of atrial flow dynamics in normals and adult patients with uncomplicated atrial septal defects

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Left and right atrial flow dynamics were compared by means of color and pulsed Doppler in order to study whether color Doppler could reliably provide differentiation between normals [15] and patients without atrial shunt at catheterization [12], vs patients with confirmed atrial septal defect [12]. The procedure consisted of sequential analysis of colored images throughout the cardiac cycle using an apical approach. In addition pulsed Doppler indices were calculated from both annular traces, relating diastolic early (E) and late (A) filling waves at each annulus (E/A); E and A waves were also summed (E + A), and the sum was related between both annuli (Tricuspid/Mitral ratio).

Sequential analysis had a 100% sensitivity and specificity for the diagnosis of atrial septal defect, showing an asymmetrical pattern with predominant images in the right atrium, from the 2nd half of systole till End-diastole, vs the symmetrical ‘Horseshoe’ pattern found over both atria for control subjects. It avoided diagnostic errors due to overriding septal images in systole in 44% of controls. There also was a significant increase of the Tricuspid/Mitral ratios, (for duration and velocity time integral of waves) in patients with atrial septal defect. The correlation coefficient between ratios and values of the Pulmonary/Systemic flow ratio invasively calculated for 10 patients was respectively 0.6 and 0.7 (p<0.01).

Sequential analysis of colored images appears highly reliable for the diagnosis of atrial septal defect; anomalies of ratios, although of moderate value for predicting shunt magnitude, substantiate the inequality of atrial fillings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Goldberg SJ, Sahn DJ, Allen HD, Valdes-Cruz LM, Hoenecke H, Carnahan Y. Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast-Fourier transform spectral analysis. Am J Cardiol 1982; 50: 1394–1400.

    Google Scholar 

  2. Sanders SP, Yeager S, Williams R. Measurements of systemic and pulmonary blood flow and QP/QS ratio using Doppler and two-dimensional echocardiography. Am J Cardiol 1983; 51: 952–956.

    Google Scholar 

  3. Kitabatake A, Inoue M, Asaomito H et al. Non invasive determination of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography. Circulation 1984; 70: 73–79.

    Google Scholar 

  4. Dittman H, Jacksch R, Voelker W, Karsch KR, Seipel L. Accuracy of Doppler echocardiography in quantification of left-to-right shunts in adult patients with atrial septal defects. J Am Coll Cardiol 1988; 11: 338–342.

    Google Scholar 

  5. Dequeker JL, Jimenez M, Gosse P et al. Estimation du rapport des débits aortique et pulmonaire par l'échographie — Doppler dans les défauts septaux. Arch mal Coeur 1988; 81: 311–316.

    Google Scholar 

  6. Benchimol A, Barreto EC, Gartlan JL. Right atrial flow velocity in patients with atrial septal defect. Am J Cardiol 1970; 25: 381–388.

    Google Scholar 

  7. Kalmanson D, Veyrat C, Derai C, Savier CH, Berkman M, Chiche P. Non invasive technique for diagnosing atrial septal defect and assessing shunt volume using directional Doppler ultrasound correlations with phasic flow velocity patterns of the shunt. Br Heart J 1972; 34: 981–991.

    Google Scholar 

  8. Pollick C, Sullivan H, Cujec B, Wilansky S. Doppler color flow imaging assessment of shunt size in atrial septal defect. Circulation 1988; 78: 522–528.

    Google Scholar 

  9. Suzuki Y, Kambara H, Kadota K et al. Detection of intracardiac shunt flow in atrial septal defect using a real-time two-dimensional color-coded Doppler flow imaging system and comparison with contrast two-dimensional echocardiography. Am J Cardiol 1985; 56: 347–350.

    Google Scholar 

  10. Goldberg SJ, Areias JC, Spitaels SEC, de Villeneuve VH. Use of time interval histographic output from echo-Doppler to detect left-to-right atrial shunts. Circulation 1978; 58: 147–152.

    Google Scholar 

  11. Veyrat C, Abitbol D, Berkman M, Malergue MC, Kalmanson D. Diagnostic et évaluation par écho-Doppler pulsé des insuffisances tricuspidiennes et des communications interventriculaires et interauriculaires. Archives des Maladies du Coeur 1980; 73: 1037–1052.

    Google Scholar 

  12. Grossman W. Shunt detection and measurement. Grossman W ed., Cardiac catheterization and angiography, 3rd Ed, Philadelphia Lea and Febiger 1986; p 155–169.

  13. Valdes-Cruz L, Tamura T, Dalton N, Elias B. Color flow Doppler shunt areas as indicators of atrial septal defect shunting. Studies in an open chest animal model and initial clinical results (abstract). Circulation 1986; 74 (suppl. II): II-145.

    Google Scholar 

  14. Kyo S, Omoto R, Takamoto S, Takanawa E. Quantitative estimation of intracardiac shunt flow in atrial septal defect by real-time two-dimensional color flow Doppler (abstract). Circulation 1984; 70 (suppl II): II-39.

    Google Scholar 

  15. Khandheria BK, Seward JB, Taylor CL et al. Utility of color flow imaging for shunt visualization in atrial septal defect. Experience in 90 patients (abstract). J Am Coll Cardiol 1987; 9: 3A.

  16. Minagoe S, Tei C, Kisanuki A et al. Non invasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach. Circulation 1985; 71: 745–753.

    Google Scholar 

  17. Morimoto K, Matsuzaki M, Tohma Y et al. Diagnosis and quantitative evaluation of atrial septal defect by transesophageal 2-D color Doppler echocardiography (abstract). Circulation 1987; 76 (suppl IV): IV-39.

    Google Scholar 

  18. Levine R, Spach MS, Boineau JP, Canent RV, Capp MP, Jewett PH. Atrial pressure-flow dynamics in atrial septal defects (secundum type). Circulation 1968; 37: 476–488.

    Google Scholar 

  19. Fraker TD, Harris PJ, Behar VS, Kisslo JA. Detection and exclusion of interatrial shunts by two-dimensional echocardiography and peripheral injection. Circulation 1979; 59: 379–384.

    Google Scholar 

  20. Weyman AE, Wann LS, Caldwell RL, Hurwitz RA, Dillon JC, Feigenbaum H. Negative contrast echocardiography: a new method for detecting left-to-right shunts. Circulation 1979; 59: 498–505.

    Google Scholar 

  21. Appleton CP, Hatle LK, Popp RL. Demonstration of restrictive ventricular physiology by Doppler echocardiography. J Am Coll Cardiol 1988; 11: 757–768.

    Google Scholar 

  22. Louie EK, Rich S, Brundage BH. Doppler echocardiographic assessment of impaired left ventricular filling in patients with right ventricular overload due to primary pulmonary hypertension. J Am Coll Cardiol 1986; 8: 1298–1306.

    Google Scholar 

  23. Lavine SJ, Tami L, Jawad I. Pattern of left ventricular diastolic filling associated with right ventricular enlargement. Am J Cardiol 1988; 62: 444–448.

    Google Scholar 

  24. Booth DC, Wisenbaugh T, Smith M, De Maria AN. Left ventricular distensibility and passive elastic stiffness in atrial septal defect. J Am Coll Cardiol 1988; 12: 1231–1236.

    Google Scholar 

  25. St. John Sutton MG, Tajik AJ, Mercier LA, Seward JB, Giuliani ER, Ritman EL. Assessment of left ventricular function in secundum atrial septal defect by computer analysis of the M Mode echocardiogram. Circulation 1979; 60: 1082–1090.

    Google Scholar 

  26. Carabello BA, Gash A, Mayer SD, Spann JF. Normal left ventricular systolic function in adults with atrial septal defect and left heart failure. Am J Cardiol 1982; 49: 1868–1873.

    Google Scholar 

  27. Tamura R, Yoganathan A, Sahn DJ. In vitro methods for studying the accuracy of velocity determination and spatial resolution of a color Doppler flow mapping system. Am Heart J 1987; 114: 152–158.

    Google Scholar 

  28. Dabestani A, Takenaka K, Allen B et al. Effects of spontaneous respiration on diastolic left ventricular filling assessed by pulsed Doppler echocardiography. Am J Cardiol 1988; 61: 1356–1357.

    Google Scholar 

  29. Meijboom KR, Rijsterborgh H, Bot H, De Boo J, Roelandt J, Bom N. Limits of reproducibility of blood flow measurements by Doppler echocardiography. Am J Cardiol 1987; 59: 133–137.

    Google Scholar 

  30. Ferguson JJ, Miller MJ, Aroesty JM, Sahagian P, Grossman W, McKay RG. Assessment of right atrial pressure-volume relations in patients with and without an atrial septal defect. J Am Coll Cardiol 1989; 13: 630–636.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work was partly supported by grants from CNAMTS and ARNTIC

Rights and permissions

Reprints and permissions

About this article

Cite this article

Veyrat, C., Legeais, S., Sainte-Beuve, D. et al. Color and pulsed Doppler studies of atrial flow dynamics in normals and adult patients with uncomplicated atrial septal defects. Int J Cardiac Imag 6, 1–10 (1990). https://doi.org/10.1007/BF01798427

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01798427

Key words

Navigation