Skip to main content
Log in

Application of intraluminal ultrasound imaging to vascular stenting

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Summary

Over the past few years catheter-based intraluminal ultrasound (IVUS) has emerged as a promising and imaginative technique which can significantly extend our understanding of atherosclerotic lesions both before and following interventions. In relation to stent implantation intravascular ultrasound appears well suited as an imaging modality — providing information as to lumen shape lesion surface and topography, as well as wall composition. To this end arteriography is unable to provide such detailed information. The purpose of this review is to outline the characteristics of stents and endoluminal support devices, currently under investigation, and the role of ultravascular ultrasound in this respect.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Holmes DR, Vliestra RE, Smith HC, Vetrovec GW, Kent KM, Cowley MJ, Faxon DP, Gruentzig AR, Kelsey SF, Detre KM, Raden MJ, Mock MB. Restenosis after percutaneous transluminal coronary angioplasty (PTCA): A report from the PTCA registry of the National Heart, Lung and Blood Institute. Am J Cardiol 1984; 53: 77C-81C.

    Google Scholar 

  2. Kaltenbach M, Kober G, Scherer D, Vallbracht C. Recurrence rate after successful coronary angioplasty. Eur Heart J 1985; 6: 276–281.

    Google Scholar 

  3. Myler RM, Shaw RE, Sterzter SH, Clark DA, Fishman J, Murphy MG. Recurrence after coronary angioplasty. Cath Cardiovas Diag 1987; 13: 77–86.

    Google Scholar 

  4. Cowley MJ, Dovros G, Kelsey SF, Van Raden M, Detre KM. Emergency coronary bypass surgery after coronary angioplasty: The National Heart Lung and Blood Institute's Percutaneous Transluminal Coronary Angioplasty Registry Experience. Am J Cardiol 1984; 53: 22C-26C.

    Google Scholar 

  5. Simpfendorfer C, Belardi J, Bellamy G, Galan KF, Granco I, Hollman J. Frequency, management and follow-up of patients with acute occlusions after percutaneous coronary angioplasty. Am J Cardiol 1987; 59: 267–269.

    Google Scholar 

  6. Sinclair IN, McCabe CH, Sippery ME, Baim DS. Predictors, therapeutic options and long-term outcome of abrupt reclosure. Am J Cardiol 1988; 61: 655–665.

    Google Scholar 

  7. Levine S, Ewels CJ, Rosing DR, Kent KM. Coronary angioplasty: clinical and angiographic follow-up. Am J Cardiol 1985; 55: 673–676.

    Google Scholar 

  8. Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N England J Med 1987; 316: 701–706.

    Google Scholar 

  9. Palmaz JC, Sibbitt RR, Renter SR, Tio FC, Rice WJ. Expandable intraluminal graft: Preliminary study. Radiology 1985; 156: 73–77.

    Google Scholar 

  10. Palmaz JC, Windeler SA, Garcia F, Tio FO, Sibbitt RR, Renter SR. Balloon expandable intraluminal grafting of atherosclerotic rabbit aortas. Radiology 1986; 160: 723–726.

    Google Scholar 

  11. Schatz RA, Palmerz C, Tio FO, Garcia F, Garcia O, Reuter SR. Balloon expandable intracoronary stents in the adult dog. Circulation 1987; 76: 450–57.

    Google Scholar 

  12. Wright KC, Wallace S, Charnsangavej C, Carrasco CH, Gianturco C. Percutaneous endovascular stents: an experimental evaluation. Radiology 1985; 156: 69–72.

    Google Scholar 

  13. Roubin GS, Robinson GA, King SB III, Gautinco C, Black AJ, Brown JE, Siegel RJ, Douglas JS Jr. Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs. Circulation 1987; 86: 891–897.

    Google Scholar 

  14. Dotter CT. Transluminally placed coil spring endarterial tube grafts-long term patency in canine popliteal artery. Invest Radiology 1969; 4: 329.

    Google Scholar 

  15. Dotter CT, Buschmann RW, McKinney MK et al. Transluminal expandable nitinol coil stent grafting: Preliminary report. Radiology 1983; 147: 259–260.

    Google Scholar 

  16. Slepian MJ, Schindler A. Polymeric endoluminal paving and sealing: A biodegradable alternative to intracoronary stenting. Circulation 1988; (Suppl IV) II-409 (abstract).

  17. Slepian MJ. Polymeric endoluminal paving and sealing: Therapeutics at the crossroad of biomechanics and pharmacology. In: Topol E (ed). Textbook of interventional cardiology. Philadelphia: W.B. Saunders, 1990; pp 647–670.

    Google Scholar 

  18. Eusterman JH, Achor RW, Kincaid OW. Atherosclerotic disease of the coronary arteries. A pathologic radiologic correlative study. Circulation 1962; 26: 11288–1295.

    Google Scholar 

  19. Kemp HG, Evans H, Elliott WC, Gorlin R. Diagnostic accuracy of selective coronary chinearteriography. Circulation 1967; 36: 526–533.

    Google Scholar 

  20. Vlodaver A, Frech R, VanTassel RA. Correlation of the antemortem coronary arteriogram and the post-mortem specimen. Circulation 1973; 47: 162–169.

    Google Scholar 

  21. Schwartz JN, Kong Y, Hackel DB, Bartel AG. Comparison of angiographic and postmortem findings in patients with coronary artery disease. Am J Cardiol 1975; 36: 174–178.

    Google Scholar 

  22. Arnett EN, Isner JM, Redwood DR et al. Coronary artery narrowing in coronary heart disease: Comparison of cine-angiographic and necropsy findings. Ann Int Med 1979; 91: 350–356.

    Google Scholar 

  23. Siegel RJ, Swan K, Edwards G, Fishbein MC. Limitations of postmortem assessment of human coronary artery fixation and luminal narrowing: Differential effects of tissue fixation and processing on vessels with different degrees of atherosclerosis. J Am Coll Cardiol 1985; 5: 342–346.

    Google Scholar 

  24. Yock PG, Johnson EL, Linker DT. Intravascular ultrasound: development and clinical potential. Am J Card Imaging 1988; 2: 185–93.

    Google Scholar 

  25. Pandian NA, Kreis A, Brockway B et al. Ultrasound angioscopy: real-time, two-dimensional, intraluminal ultrasound imaging of blood vessels. Am J Cardiol 1988; 62: 493–4.

    Google Scholar 

  26. Hodgson J McB, Graham SP, Savakus AD, Dame SG, Stepehens DN, Dhillon PS, Brands D, Sheehan H, Eberle MJ. Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system. Int J Card Imaging 1989; 4: 187–193.

    Google Scholar 

  27. Nishimura RA, Edwards WD, Warnes CA, Reeder GS, Holmes DR, Tajik AJ, Yock PG. Intravascular ultrasound imaging: in vitro validation and pathologic correlation. J Am Coll Cardiol 1990; 16: 145–54.

    Google Scholar 

  28. Gussenhoven EJ, Essed CE, Lancée CT, Mastik F, Frietman P, Van Egmond FC, Reiber J, Bosch H, van Urk H, Roelandt J, Bom N. Arterial wall characteristics determined by intravascular ultrasound: an in vitro imaging study. J Am Coll Cardiol 1989; 14: 947–52.

    Google Scholar 

  29. Webb JG, Yock PG, Slepian MJ, White NW, Hui PY, Rowe MH, Linker DT, Finkbeiner WE. Intravascular ultrasound: significance of the three-layered appearance of normal muscular arteries. J Am Coll Cardiol 1990; 15: 17A.

  30. Pandian NG, Kreis A, Brockway B, Sacharoff A, Caro R. Intravascular high frequency two-dimensional ultrasound detection of arterial dissection and intimal flaps. Am J Cardiol 1990; 65: 1278–80.

    Google Scholar 

  31. Slepian MJ, White NW, Rowe MH, Webb J, Brescan O, Yock PG. Intravascular two-dimensional ultrasound: a sensitive imaging modality for detection of complete vs partial stent expansion. Radiology (Accepted RSNA) 1989.

  32. Chokshi SK, Hogan J, Desai V, Daod M, Cross F, Parsonnet V, Isner JH. Intravascular ultrasound assessment of implanted endovascular stents. J Am Coll Cardiol 1990; 15: No 2 29A.

  33. Dotter CT. Transluminally placed coil-spring endarterial tube grafts, long term patency in canine popliteal artery. Invest Radiol 1969; 4: 329–332.

    Google Scholar 

  34. Cragg A, Lund G, Rysavy J, Castaneda F, Castaneda-Zuniga W, Amplatz K. Nonsurgical placement of arterial endoprostheses. A new technique using nitinol wire. Radiology 1983; 147: 261–263.

    Google Scholar 

  35. Maas D, Zolikofer CL, Lambader F, Senning A. Radiological followup of transluminally inserted vascular endoprostheses: An experimental study using experimental spiral. Radiology 1984; 152: 659–663.

    Google Scholar 

  36. Wright KC, Wallace S, Charnsangavej C, Carrasco CH, Gianturco C. Percutaneous endovascular stents: An experimental evaluation. Radiology 1985; 156: 69–72.

    Google Scholar 

  37. Palmaz JC, Sibbit RR, Reuter SR, Tio FO, Rice WJ, Expandable intraluminal graft: A preliminary study. Radiology 1985; 156: 73–77.

    Google Scholar 

  38. Schatz RA, Palmaz JC, Tio FC et al. Balloon expandable intracoronary stents in the adult dog. Circulation 1987; 76: 450–457.

    Google Scholar 

  39. Palmaz JC, Schatz RA, Richter G, Gardiner G, Becker G, Garcia O. Intraluminal stenting of iliac artery stenoses: Preliminary report of a multicenter trial. Circulation 1988; 78 (suppl II): II-415.

    Google Scholar 

  40. Schatz RA, Palmaz JC, Tio F, Garcia O. Report of a new articulated baloon-expandable intravascular stent. Circulation 1988; 78 (Suppl IV) 449.

    Google Scholar 

  41. Schatz RA, Baim DS, Leon M. Clinical experience with the Palmaz-Schatz coronary stent: Initial results of a multi-center study. Circulation 1991; 83: 148–161.

    Google Scholar 

  42. Roubin GS, Robinson KA, King SB, Gianturco C, Black AJ, Brown JE, Seigel RJ, Douglas JS. Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs. Circulation 1987; 76: 891–897.

    Google Scholar 

  43. Roubin GS. Status of percutaneous transluminal coronary angioplasty. Curr Probl Cardiol 1990; 15: 723–829.

    Google Scholar 

  44. Roubin GS, Agarwal SK, Dean LS et al. What are the predictors of acute complications following coronary artery stenting? Single institution experience. J Am Coll Cardiol 1990; 17: 281A.

  45. Roubin GS, Hearn JA, Carlin SF et al. Angiographic and clinical follow-up in patients receiving a balloon expandable, stainless steel stent for prevention or treatment of acute closure after PtCA. Circulation 1990; 82 (Suppl III) 191.

    Google Scholar 

  46. Fry S. Intravascular stents: A physicians guide, pp 44–51, Kanuai, 1990.

  47. White CJ, Ramee SR, Banks AK, Ross TC, Wiktor D, Choksi S, Price HL, Isner JM. Angiographic patency of a tantalum coil stent. J Am Coll Cardiol 1990; 15: No. 2, 118A.

  48. Strecker EP, Liermann D, Barth KH, Wolf HR, Freudenberg N, Berg G, Westphal M, Tsikuras P, Savin M, Schneider B. Expandable tubular stents for treatment of arterial occlusive diseases: experimental and clinical results. Work in progress. Radiology. 1990; 175: 97–102.

    Google Scholar 

  49. Barth KH, Virmani R, Strecker EP, Savin MA. Lindisch D, Matsumoto AH, Teitelbaum GP. Flexible tantalum stents implanted in aortas and iliac arteries: effects in normal canines. Radiology. 1990; 175: 91–6.

    Google Scholar 

  50. Sigwart U, Puel J, Mirkovitch V, Jofre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Eng J Med 1987; 316: 701–706.

    Google Scholar 

  51. Sigwart U, Urban P, Sadeghi H, Kappenberger L. Implantation of 100 coronary artery stents: Learning curve for the incidence of acute early complications. J Am Coll Cardiol 1989; 13: 107A.

  52. Bertrand ME, Rickards AF, Serruys PW. Coronary stent implantation for primary and secondary prevention of restenosis after PTCA: results of a pilot multicenter trial (1986/1987) (CASIS Trial) Eur Heart J 1988; 9 (Suppl 1): 55.

    Google Scholar 

  53. Puel J, Haddad J, Courtault A et al. Angiographic follow-up of percutaneous coronary stenting. Circulation 1988; 78 (Suppl II): II-406.

    Google Scholar 

  54. Serruys PW, Strauss BH, Beatt KJ, Bertrand ME, Puel J, Rickards AF, Meier B, Goy JJ, Vogt P, Kappenberger L. Angiographic follow-up after placement of a self-expanding coronary-artery stent. N Engl J Med 1991; 324: 13–7.

    Google Scholar 

  55. Kambic H, Sutton C, Oku T, Sugita Y, Murabayashi S, Harasaki H, Kasick J, Shirey E, Nose Y. Biological performance of TiNi shape memory alloy vascular ring prostheses: a two year study. Int J Art Organ 1988; 11: 487–492.

    Google Scholar 

  56. Sutton CS, Kambic HE, Oku T, karasaki H, Emoto H, Tominaga R, Hollman J. Stenting fails to prevent recurrent stenosis in the rabbit model of atherosclerosis. Circulation 1988; 78 (Suppl IV): II-414.

    Google Scholar 

  57. Juilliere Y, Serruys PW, Beatt KJ, Sigwart U. Contribution of self-expansion of the stent and additional endoluminal dilatation within the stent to improve patency of stented human coronary arteries. Circulation 1988; 78: II-407.

    Google Scholar 

  58. Hampton JR, Mitchell JRA. Thrombosis, in Human blood coagulation, haemostasis and thrombosis, Biggs, R. ed. Blackwell Scientific, Oxford, 1972; 476.

    Google Scholar 

  59. DePalma VA, Baier RE, Ford JW. Investigation of three surface properties of several metals and their relation to blood compatibility. J Biomed Mater Res 1972; 3: 37–75.

    Google Scholar 

  60. Schultz JS, Lindenauer SM, Penner JA, Barenberg S. Determinants of thrombus formation on surfaces. ASAIO Trans 1980; 26: 279–283.

    Google Scholar 

  61. Baier RE. Initial events in interactions of blood with a foreign surface. J Biomed Mat Res 1969; 3: 191–206.

    Google Scholar 

  62. Robinson KA, Roubin GS, King SB, Black AJ, Stack JE, Hunter RL. Inhibition of coronary thrombosis after stent placement in swine by copolymer poloxamer 188. Circulation 1988; 78: II-407.

    Google Scholar 

  63. Schatz RA. A view of vascular stents. Circulation 1989; 79: 445–457.

    Google Scholar 

  64. Schatz RA, Palmaz JC, Tio F, Garcia O. Report of a new radiopaque balloon expandable intravascular stent (RBEIS) in canine coronary arteries. Circulation 1988; 78: II-448.

    Google Scholar 

  65. Van der Giessen WJ, van Woerkens G, Beatt KJ, Serruys PW, Verdouw PD. Coronary stenting with a radiopaque, balloon-expandable stent in pigs. Circulation 1989; 80: (II-17).

    Google Scholar 

  66. Minic CR, Stemerman MB, Insull W. Effect of regenerated endothelium on lipid accumulation in the arterial wall. Proc Nat Acad Sci USA 1977; 74: 1724–1728.

    Google Scholar 

  67. Palmaz JC. Balloon-expandable Intravascular stent. Am J Radiol 1988; 150: 1263–1269.

    Google Scholar 

  68. Serruys PW, Beatt KJ, Koning R, Bertrand M, Puel J, Rickards A, Sigwart U. Early and late assessment of morphological change after stent implantation. Circulation 1988; 78: II-408.

    Google Scholar 

  69. Devices for Vascular Intervention (conference communication), Directional Coronary Atherectomy Course, San Diego, Ca. April 12, 1991.

  70. Gussenhoven WJ, Essed CE, Frietman P, Mastik F, Lancée C, Slager C, Serruys PW, Gerritsen P, Pieterman H, Bom N. Intravascular echographic assessment of vessel wall characteristics: a correlation with histology. Int J Card Imaging 1989; 4: 105–116.

    Google Scholar 

  71. Siegel rJ, Fishbein MC, Chae JS, Potkin B, Berlin M, Helfant RH. Origin of the 3-ringed appearance of human arteries by ultrasound: microdissection with ultrasonic and histologic correlation. J Am Coll Cardiol 1990; 15: 17A.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Slepian, M.J. Application of intraluminal ultrasound imaging to vascular stenting. Int J Cardiac Imag 6, 285–311 (1991). https://doi.org/10.1007/BF01797860

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01797860

Key words

Navigation