Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directly visualizes the plaque. Intravascular ultrasound fulfils these criteria. This presentation will provide evidence that intravascular ultrasound may prove complimentary or even superior to angiography as an imaging modality.

Intravascular ultrasound demonstrates excellent representations of lumen and plaque morphology ofin vitro specimens compared with histology. There is very close intraobserver and interobserver variability of measurements made from intravascular ultrasound images. Phantom studies of stenoses in a tube model demonstrate that angiography can misrepresent the severity of stenosis when the lumen contour is irregular and not a typical ellipse, whereas intravascular ultrasound reproduces the cross-sectional morphology more accurately since it images the artery from within.In vitro studies of the atherosclerotic plaque tissue characteristics compare closely with the echo representation of fibrosis, calcification, and lipid material. In addition,in vitro studies of balloon angioplasty demonstrate that intravascular ultrasound accurately represents the changes in the structure of artery segments following balloon dilatation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Tobis JM, Mallery JA, Gessert J, Griffith J, Mahon D, Bessen M, McLeay L, Moriuchi M, McRae M, Henry WL. Intravascular Ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro. Circulation 1989; 80: 873–82.

    Google Scholar 

  2. Tobis JA, Mallery JA, Lehmann K, Zalesky P, Griffith J, Gessert J, Moriuchi M, McRae M, Bessen M, Dwyer M-L, Greep N, Henry WL. Intravascular ultrasound imaging of human coronary arteriesin vivo: analysis of tissue characterizations with comparison toin vitro histologic specimens. Circulation 1991; 83: 913–26.

    Google Scholar 

  3. Lyon RT, Zarins CK, Lu C-T, Yang C-F, Glagov S. Vessel, plaque, and lumen morphology after transluminal balloon angioplasty: Quantitative study in distended human arteries. Arteriosclerosis 1987; 7: 306–14.

    Google Scholar 

  4. Yock PG, Johnson EL, Linker DT. Intravascular ultrasound: Development and clinical potential. Am J Card Imaging 1988; 2: 185–93.

    Google Scholar 

  5. Nissen SE, Grines CL, Gurley JC, Sublett K, Haynie D, Diaz C, Booth DC, DeMaria AN. Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography. Circulation 1990; 81: 660–6.

    Google Scholar 

  6. Gussenhoven EJ, Essed CE, Lancée CT, Mastik F, Frietman P, Van Egmond FC, Reiber J, Bosch H, Van Urk H, Roelandt J, Bom N. Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study. J Am Coll Cardiol 1989; 14: 947–52.

    Google Scholar 

  7. Vlodaver Z, Frech R, Van Tassel RA, Edwards JE. Correlation of the antemortem coronary arteriogram and the postmortem specimen. Circulation 1973; 47: 162–9.

    Google Scholar 

  8. Mallery JA, Tobis JM, Griffith J, Gessert J, McRae M, Moussabeck O, Bessen M, Moriuchi M, Henry WL. Assessment of normal and atherosclerotic arterial wall thickness with an intravascular ultrasound imaging catheter. Am Heart J 1990; 119 (6): 1392–1400.

    Google Scholar 

  9. Potkin BN, Bartorelli AL, Gessert JM, Neville RF, Almagor Y, Roberts WC, Leon MB. Coronary artery imaging with intravascular high-frequency ultrasound. Circulation 1990; 81: 1575–85.

    Google Scholar 

  10. Moriuchi M, Tobis JM, Gordon I, Bergman A, Griffith J, Henry WL. Functional significance of arterial stenoses predicted by angiography and intravascular ultrasound imaging catheter. J Am Coll Cardiol 1990; 15 (2) A: 106.

    Google Scholar 

  11. Waller BF, Roberts WC. Amount of narrowing by the atherosclerotic plaque in 44 non-bypassed and 52 bypassed major epicardial coronary arteries in 32 necropsy patients who died within one month of aortocoronary bypass grafting. Am J Cardiol 1980; 46: 956–62.

    Google Scholar 

  12. Little WC, Constantinescu M, Applegate RJ, Kutcher MA, Burrows MT, Kahl FR, Santamore WP. Can coronary angiography predict the site of a subsequent myocardial infarction in patients with mild-to-moderate coronary artery disease? Circulation 1988; 78: 1157–66.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tobis, J.M., Mahon, D.J., Moriuchi, M. et al. Intravascular ultrasound imaging following balloon angioplasty. Int J Cardiac Imag 6, 191–205 (1991). https://doi.org/10.1007/BF01797851

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01797851

Key words

Navigation