References
Nissen SN, Gurley JC, Grines C, Booth DC, McClure R, Berk M, Fischer C, DeMaria AN. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation 1991; 84: 1087–1099.
Nakamura S, Mahon DJ, Maheswaran B, Gutfinger DE, Colombo A, Tobis JM. An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 1995; 25: 633–639.
Stahr P, Rupprecht NJ, Voiglander T, Kearney P, Erbel R, Koch L, Krass S, Brennecke R, Meyer J. Importance of calibration for diameter and area determination by intravascular ultrasound. Int J Cardiac Imag 1996; 12: 221–229 (in this issue).
Anderson MH, Simpson IA, Katritsis D, Davies MJ, Ward DE. Intravascular ultrasound imaging of the coronary arteries: an in vitro evaluation of measurement of area of the lumen and atheroma characterization. Br Heart J 1992; 68: 276–281.
Ten Hoff H, Korbijn A, Smith TH, Klinkhamer JF, Bom N. Imaging artifacts in mechanically driven ultrasound catheters. Int J Cardiac Imag 1989; 4: 195–199.
Kimura BJ, Bhargava V, Palinski W, Russo RJ, DeMaria AN. Distortion of intravascular ultrasound images due to nonuniform angular velocity of mechanical-type transducer. Am Heart J 1996: 328–336.
Gussenhoven EJ, Essed CE, Lancee CT, Mastik F, Frietman P, Van Egmond FC, Reiber J, Bosch H, Van Urk H, Roelandt J, Bom N. Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study. J Am Coll Cardiol 1989; 14: 947–952.
Pandian NG, Kreis A, Brockway BS, Isner JM, Sacharoff A, Boleza E, Caro R, Muller D. Ultrasound angioscopy: real-time, two-dimensional, intraluminal ultrasound imaging of blood vessels. Am J Cardiol 1988; 62: 493–494.
Pandian NG, Kreis A, O'Donnell T. Intravascular Ultrasound estimation of arterial stenosis. J Am Soc Echo 1989; 2: 390–397
Mallaery JA, Tobis JM, Grifith J, Gessert J, Mcrai M, Moussabeck O, Bessen M, Moriuchi M, Henry WI. Assessment of normal and atherosclerotic arterial wall thickness with an intravescular ultrasound imaging catheter. Am Heart J 1990; 119: 1392–1400.
Nishimura RA, Edwards WD, Warnes CA, Reeder GS, Holmes DR, Tajik AJ, Yock PG. Intravascular ultrasound imaging:in vitro validation and pathologic correlation. J Am Coll Cardiol 1990; 16: 145–154.
Di Mario C, Madretsma S, Linker D, The SHK, Bom N, Serruys PW, Gussenhoven EJ, Roelandt JRTC. The angle of incidence of the ultrasonic beam: A critical factor for the image quality in intravascular ultrasonography. Am Heart J 1993; 125: 442–448.
Nakamura S, Colombo A, Gaglione A, Almagor Y, Goldberg SL, Maierllo L, Finci L, Tobis JM. Intracoronary ultrasound observations during stent implantation Circulation 1994; 89(5): 2026–2034.
Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM. Intracoronary stenting without anticoagulation accomplished with intrasvascular ultrasound guidance. Circulation 1995; (91): 1676–1688.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bhargava, V., Penny, W.F. & Arbab-Zadeh, A. Editorial comment. Int J Cardiac Imag 12, 231–232 (1996). https://doi.org/10.1007/BF01797735
Issue Date:
DOI: https://doi.org/10.1007/BF01797735