Conclusion
Intraoperative color Doppler offers rapid and accurate information about the presence and severity of mitral regurgitation at the time of surgery. This technique provides instantaneous evaluation of the adequacy of mitral and tricuspid valvuloplasty and appears capable of predicting their postoperative outcome. This approach may ultimately allow for valve repair procedures to be performed in greater numbers of patients with better control over outcome and lower reoperation rates.
Similar content being viewed by others
References
Perier P, Deloche A, Chauvaud S et al. Comparative evaluation of mitral valve repair and replacement with Starr, Bjork, and porcine valve prostheses. Circulation 1984; 70 (suppl I): 187–92.
Bonchek LI. Correction of mitral valve disease without mitral valve replacement. Am Heart J 1982; 104: 865–8.
Goldman ME, Mora F, Fuster V, Guarino T, Mindich BP. Is mitral valvuloplasty superior to mitral valve replacement for preservation of left ventricular function? An intraoperative two-dimensional echocardiographic study J Am Coll Cardiol 1986; 7: 161A.
David TE, Uden DE, Strauss HD. The importance of the mitral apparatus in left ventricular function after correction of mitral regurgitation. Circulation 1983; 68 (suppl II): 76–82.
King R, Schaff H, Danielson G et al. Surgery for tricuspid regurgitation late after mitral valve replacement. Circulation 70 1984; (suppl I): 193–197.
Antunes MJ, Colsen PR, Kinsley RH. Mitral valvuloplasty: a learning curve. Circulation 1983; 68 (suppl II): 70–75.
Carpentier A, Chauvaud S, Fabiani JN, Deloche A, Relland I, Lessana A, D'Allaines C, Blondeau P, Piwnica A, Dubost P. Reconstructive surgery of mitral valve incompetence. Ten year appraisal. J Thorac Cardiovasc Surg 1980; 79: 338–48.
Mindich BP, Goldman ME, Fuster V, Burgess N, Litwak R. Improved intraoperative evaluation of mitral valve operations utilizing two-dimensional contrast echocardiography. J Thorac Cardiovasc Surg 1985; 90: 112–8.
Maurer G, Czer L, Chaux A et al. Intraoperative Doppler color flow mapping for assessment of valve repair for mitral regurgitation. Am J Cardiol 1987; 60: 333–7.
Czer L, Maurer G, Bolger AF et al. Intraoperative evaluation of mitral regurgitation by Doppler color flow mapping. Circulation 1987; 76 (suppl III): 108–16.
Czer L, Maurer G, Kleinman J et al. Tricuspid valve repair: operative and follow-up evaluation by Doppler color flow mapping. Joumal of Thoracic and Cardiovascular Surgery (in press).
Pagliero KM, Yates AK. Peroperative assessment of mitral valve function. J Thorac Cardiovasc Surg 1972; 63: 458–60.
King H, Csicsko J, Leshnower A. Intraoperative assessment of the mitral valve following reconstructive procedures. Ann Thorac Surg 1980; 29: 81–83.
Fuchs RM, Heuser RR, Yin FC, Brinker JA. Limitations of pulmonary wedge V-waves in diagnosing mitral regurgitation. Am J Cardiol 1982; 49: 849–54.
Kleinman I, Maurer G. Transesophageal echocardiography and color flow mapping. In: Maurer G, Mohl W, eds.Echocardiography and Doppler in cardiac surgery. New York, N.Y.: Igaku-Shoin Medical Publishers, in press.
Carpentier A, Chauvaud S, Fabiani JN et al. Reconstructive surgery of mitral valve incompetence. Ten year appraisal. J Thorac Cardiovasc Surg 1980; 79: 338–48.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Maurer, G., Czer, L.S.C. Intraoperative color Doppler assessment of mitral and tricuspid valvuloplasty. Int J Cardiac Imag 4, 11–13 (1989). https://doi.org/10.1007/BF01795111
Issue Date:
DOI: https://doi.org/10.1007/BF01795111