This study was carried out in order to obtain data on the relation between tumour structures seen in computer tomograms and the corresponding histopathology and cytology. Nine consecutive patients were studied, and stereotactic biopsies were obtained from sites determined on contrast enhanced computer tomograms. Biopsies were obtained from tumour areas with high and low contrast uptake and from the low attenuating areas surrounding the tumours. The results indicated a close correlation between the microscopical morphology of gliomas and the pattern of the computer tomogram. Biopsy samples from low-uptake central areas contained tumour tissue, necrotic tissue, and in one case a cyst. Biopsies from high-uptake areas typically contained tumour tissue, whereas biopsies from low-uptake surrounding areas contained oedematous non-tumour tissue. For tumour diagnosis biopsies should be obtained from both low and high attenuating tumour areas.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Backhand, E. O., A new instrument for stereotaxic brain tumour biopsy. Acta Chir. Scand.137 (1971), 825–827.

    PubMed  Google Scholar 

  2. Bergström, M., Greitz, T., Stereotaxic computed tomography. Amer. J. Roentgenol.127 (1976), 167–170.

    Google Scholar 

  3. Hounsfield, G., Computerized transverse axial scanning (tomography). Brit. J. Radiol.46 (1973), 1016.

    PubMed  Google Scholar 

  4. Kernohan, J., Mabou, R., Svien, H., Adson, A., A simplified classification of the gliomas. Proceedings of the staff meetings of the Mayo clinic24 (1949), number 3.

  5. Leksell, L., Stereotaxis and radiosurgery. Springfield, Ill.: Ch. C Thomas. 1971.

    Google Scholar 

  6. Norman, D., Newton, T. H., Localization with the EMI scanner. Amer. J. Roentgenol.127, No. 4 (1975), 961–964.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Boëthius, J., Collins, V.P., Edner, G. et al. Stereotactic biopsies and computer tomography in gliomas. Acta neurochir 40, 223–232 (1978). https://doi.org/10.1007/BF01774748

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01774748

Keywords

Navigation