Summary
Intraoperative visualization of coronary artery anatomy and morphology is an innovative method to evaluate patients undergoing coronary bypass surgery. With the high frequency ultrasonic technique we were able to measure diameters of internal mammary arteries (IMA) before and after dilatation. Probe dilatation of the IMA led to an increase of the IMA diameter of 46% while balloon dilatation was more successful resulting in an enlargement of 66%. The measurement of the flow rates showed similar changes (95% vs. 275%). Furthermore we were able to reproduce coronary artery lesions by echocardiography which could not be demonstrated in the angiogram.
Similar content being viewed by others
References
Sahn D, Barrat-Boyes BG, Graham K, Kerr A, Roche A, Hill D, Glenn W. Ultrasonic imaging of coronary atherosclerotic lesions in open chest human: Evaluation of coronary atherosclerotic lesions during cardiac surgery. Circulation 1982; 66: 1034–44.
Hiratzka LF, McPherson DD, Brandt B, Lamberth Jr WC, Marcus ML, Kerber R. Intraoperative high-frequency epicardial echocardiography in coronary revascularisation: locating deeply embedded coronary arteries. Ann Thoracic Surg 1986; 42 -suppl: 9.
Likungu J, Murday H, Quade G, Kirchhoff PG. Intraoperative echocardiographic visualization of coronary arteries before and after aorto-coronary bypass grafting. Int J Cardiac Imaging 1988; 3: 161–7.
Hiratzka LF, McPherson DD, Lamberth W, Brandt B, Armstron ML, Hunt M, Kreso R, Megan MD, Tompkins PK, Marcus ML, Kerber R. Intraoperative evaluation of coronary artery bypass graft anastomosis using high frequency epicardial echocardiography. Circulation 1985; 72 -suppl 3: 130.
Kuhnen R, Grube E, Likungu J, Lüderitz B. Intraoperative Darstellung von Koronararterien: Messungen von Blutfluß-parametern mit Hilfe des Duplex-Systems. Z Kardiol 1987; 76 suppl 1: 61.
Likungu J, Grube E, Kirchhoff PG, Quade G, Schubert P. Intraoperative echocardiographic visualization of coronary arteries and flow measurements of coronary bypass grafts were correlated to postoperative findings of graft patency assessed by digital substraction angiography performed 10 days postoperatively. Thorac Cardiovasc Surg 1986; 34a 1:29.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Likungu, J., Schmid, C., Paterakis, S. et al. Intraoperative sonographic measurements of the internal mammary artery as a coronary bypass conduit. Int J Cardiac Imag 5, 33–37 (1989). https://doi.org/10.1007/BF01745230
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01745230