Abstract
The test-retest reliability of 24-hour ambulatory blood pressures (ABP) was examined using correlational analyses as well as idiographic and nomothetic time-series regression analyses. Thirty normotensives (equal males and females) underwent ABP monitoring on three occasions, each of which was separated by a week. When analyzing the data, various postural positions, activities, and locations were controlled for in order to differentially assess the effects of these variables independently. Correlational analyses found the overall test-retest reliability of the ABPs to be quite good (SBP r =.84–.88, DBP r =.83–.86, HR r =.91–.95). Correlations examined within specific postural positions, activities, and locations were also significant. The time-series regression analyses used confirmed the reproducibility of the ABPs, with no greater than 20% of the subjects showing significant changes in ABPs over the three monitoring periods. Gender effects were also examined. In general, males had significantly higher systolic ABPs overall, although there was no influence of gender in terms of the test-retest reliability of the ABPs.
Similar content being viewed by others
References
Antivalle, M., Lattuada, S., Paravieini, M., & Rindi, M. (1991). Determinants of differences in normal values of 24-hour BP in a collaborative study. (Abstract).American Journal of Hypertension, 4, (5, Part 2), 98A.
Blanchard, E. B., Cornish, P. J., Wittrock, D., Jaccard, J., & Eisele, G. (1990). Effects of 24-hour ambulatory blood pressure monitoring on daily activities.Health Psychology, 9, 647–652.
Cheung, D., & Weber, M. A. (1988). Ambulatory blood pressure measurements: Practical considerations, methodology, feasibility, and implications in the management of hypertension.Cardiovascular Clinics, 18, 125–138.
Clark, S. J., Coats, H. J. S., Prior, C., Conway, J., & Sleight, P. (1991). Ambulatory blood pressure in the general population. (Abstract).Journal of Hypertension 9(Suppl. 8), S86.
Cornish, P. J., Blanchard, E. B., & Jaccard, J. (1994) The relationship between 24-hour ambulatory blood pressures and laboratory measures of cardiovascular reactivity.Biofeedback and Self-Regulation, 19, 193–209.
Garrett, S. S., Garrett, B. N., Carr, A. A., Rhoades, R. B., Prisant, L. M., & Bottini, P. B. (1991). Are circadian blood pressure patterns reproducible as measured by 24-hour ambulatory blood pressure monitoring? (Abstract)American Journal of Hypertension, 4 (5, Part 2) 100A.
Gellman, M., Spitzer, S., Ironson, G., Llabre, M., Soab, P., DeCarlo-Posin, R., Weidler, D. J., & Schneiderman, N. (1990). Posture, place, and mood effects on ambulatory blood pressure.Psychophysiology, 27 544–551.
Hinderliter, A. L., Light, K. C., & Willis, P. W. (1991). Left ventricular mass and diastolic filling: Relation to blood pressure and demographic variables in a healthy biracial sample.American Journal of Hypertension, 4 579–585.
Jaccard, J., & Wan, C.K. (1993). Statistical analysis of temporal data with many observations: Issues for behavioral medicine data.Annals of Behavioral Medicine, 15 41–50.
Jaccard, J., Wan, C. K., Musso, A., & Blanchard, E. B. (1991). Research design and data analysis of ambulatory blood pressure data. Unpublished manuscript. Center for Stress and Anxiety Disorders, 1535 Western Avenue, Albany, New York, 12203.
James, G. D., Pickering, T. G., Yee, L. S., Harshfield, G. A., Riva, S., & Laragh, J. H. (1988). The reproducibility of average ambulatory, home, and clinic pressures.Hypertension, 11 275–279.
Mancia, G., Casadel, R., Mutti, E., Trazzi, S., & Parati, G. (1989). Ambulatory blood pressure monitoring in the evaluation of antihypertensive treatment.The American Journal of Medicine, 87(Suppl. 6B), 64S–69S.
Marler, M. R., Jacob, R. G., Lehoczky, J. P., & Shapiro, A. P. (1988). The statistical analysis of treatment effects in 24-hour ambulatory blood pressure recording.Statistics in Medicine, 7 697–716.
McKinney, M. E., Miner, M. H., Ruddel, H., McIlvain, H. E., Witte, H., Buell, J. C., Eliot, R. S., & Grant, L. B. (1985). The standardized mental stress test protocol: Test-retest reliability and comparison with ambulatory blood pressure monitoring.Psychophysiology, 22 453–463.
Musso, A., Blanchard, E. B., & McCoy, G. C. (1991). Evaluation of thermal biofeedback treatment of hypertension using 24-hr ambulatory blood pressure monitoring.Behaviour Research and Therapy, 29 469–478.
Pessina, A. C., Palatini, P., Sperti, G., Cordone, L., Ventura, E., & Dal Palu, C. (1984). Adaptation to non-invasive continuous blood pressure monitoring. In M. A. Weber, & J. I. M. Drayer (Eds.),Ambulatory blood pressure monitoring. New York: Springer-Verlag.
Pickering, T. G. (1993). Applications of ambulatory blood pressure monitoring in behavioral medicine.Annals of Behavioral Medicine, 15 26–32.
Pickering, T. G. (1988). The influence of daily activity on ambulatory blood pressure.American Heart Journal, 116 1141–1145.
Ravogli, A., Trazzi, S., Villani, A., Mutti, E., Cospidi, C., Sampieri, L., DeAmbroggi, L., Parati, G., Zanchetti, A., & Mancia, G. (1990). Early 24-hour blood pressure elevation in normotensive subjects with parental hypertension.Hypertension, 16 491–497.
Staessen, J. A., Fagard, R. H., Lijnen, P. J., Thijs, L., Van Hoof, R., & Amery, A. K. (1991a). Mean and range of ambulatory pressure in normotensive subjects from a meta-analysis of 23 studies.The American Journal of Cardiology, 67 723–727.
Torre, L. B., Rouse, I. L., & Beilin, L. J. (1989). Reproducibility of 24-hour noninvasive ambulatory blood pressure monitoring using the Suntech Accutracker.Clinical and Experimental Pharmacology and Physiology, 16 247–251.
Trazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., Mancia, G. (1991). Reproducibility of non-invasive intra-arterial blood pressure monitoring: Implications for studies on antihypertensive treatments.Journal of Hypertension, 9 115–119.
Van Egeren, L. F., & Sparrow, A. W. (1989). Laboratory stress testing to assess real-life cardiovascular reactivity.Psychosomatic Medicine, 51 1–9.
Weber, M. A., Drayer, J. I. M., & Chard, E. R. (1984). Noninvasive automated blood pressure monitoring in ambulatory normotensive men. In M. A. Weber, & J. I. M. Drayer (Eds.),Ambulatory blood pressure monitoring. NY: Springer-Verlag.
Wong-Chung, M. Y., Smits, P., Lenders, J. W. M., & Thien, T. (1991). Reproducibility of the blood pressure fall at night in healthy normotensive volunteers.Journal of Hypertension, 9(Suppl. 6), S324-S325.
Zachariah, P. K., Sheps, S. G., Bailey, K. R., Wiltgen, C. M., & Moore, A. G. (1991). Age-related characteristics of ambulatory blood pressure load and mean blood pressure in normotensive subjects. (Abstract).Journal of Hypertension, 9(Suppl. 8), S86-S87.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cornish, P.J., Blanchard, E.B. & Jaccard, J. Test-retest reliability of 24-hour ambulatory blood pressures. Biofeedback and Self-Regulation 20, 137–154 (1995). https://doi.org/10.1007/BF01720970
Issue Date:
DOI: https://doi.org/10.1007/BF01720970