Skip to main content
Log in

Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media

  • Note
  • Published:
European Journal of Clinical Microbiology and Infectious Diseases Aims and scope Submit manuscript

Abstract

The recovery rates and times to detection of microorganisms isolated from two similar blood culture media, one containing saponin, were compared. A total of 2117 blood cultures were analysed in a prototype automated blood culture system. Significantly more gram-positive organisms (P<0.05) and gram-negative organisms (P<0.05), includingEnterobacterlaceae (P<0.05) were recovered from the lytic medium. Average time to detection in the lytic medium was 15.8 h, compared to 22.7 h in the other medium (P<0.001). The improved recovery of microorganisms was most pronounced in blood samples obtained from patients being treated with antibiotics at the time of venesection. In vitro experiments on antibiotic affected bacteria confirmed the protective effect of saponin.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Washington JA: The use of lysis-based procedures for blood culture. European Journal of Clinical Microbiology & Infectious Diseases (1991) 10:618–619

    Google Scholar 

  2. Scribner RK, Welch DF: Neutralization of the inhibitory effects of sodium polyanetholesulphonate onNeisseria meningitis in blood cultures processed with the DuPont isolator system. Journal of Clinical Microbiology (1984) 20:40–42.

    Google Scholar 

  3. Brannon P, Kiehn TE: Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture. Journal of Clinical Microbiology (1985) 22:951–954

    Google Scholar 

  4. Kelly MT, Fortasek MF, Abbott TM, Hale De VC, Dizikes JR, Boshard R, Buck GE, Martin WJ, Matesen JM: Clinical evaluation of centrifugation technique for the detection of septicaemia. Journal of the American Medical Association (1983) 250:2185–2188

    Google Scholar 

  5. Kirkley BA, Easley KA, Washington JA: Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections. Journal of Clinical Microbiology (1994) 32:1547–1549

    Google Scholar 

  6. Hellinger WC, Cawley JJ, Alvarez S, Hogan SF, Harmsen WS, Illstrup DM, Cockerill FR III: Clinical comparison of the Isolator and BacT/Alert aerobic blood culture systems. Journal of Clinical Microbiology (1995) 33:1787–1790

    Google Scholar 

  7. Murray P, Spizzo AW, Niles AC: Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and Isolator lysis-centrifugation system. Journal of Clinical Microbiology (1991) 29:901–905

    Google Scholar 

  8. Rohner P, Burkardt H, Dreismann H, Auckenthaler R: Evaluation of the new improved BHI-lysis blood culture medium for the BCB Roche system. European Journal of Clinical Microbiology & Infectious Diseases (1991) 10:620–624

    Google Scholar 

  9. Kirkley BA, Easley KA, Basille BA, Washington JA: Controlled clinical comparison of two lysis-based blood culture systems, Isolator and Septi-Chek Release, for detection of bloodstream infections. Journal of Clinical Microbiology (1993) 31:2114–2117

    Google Scholar 

  10. Rohner P, Pepey B, Auckenthaler R: Evaluation of two commercial blood culture media for the detection of blood-borne pathogens. European Journal of Clinical Microbiology & Infectious Diseases (1994) 13:28–32

    Google Scholar 

  11. Rohner P, Pepey B, Auckenthaler R: Comparative evaluation of Bactec aerobic Plus/F and Septi-Chek Release blood culture media. Journal of Clinical Microbiology (1996) 34:126–129

    Google Scholar 

  12. Hollick GE, Edinger R, Martin B: Clinical comparison of the Bactec 9000 standard Anaerboc/F and Lytic/F blood culture media. Diagnostic Microbiology and Infectious Diseases (1996) 24:191–196

    Google Scholar 

  13. Stevens CM, Swaine D, Butler C, Carr AH, Weightman A, Catchpole RC, Healing DE, Elliott TS: Development of o.a.s.i.s., a new automated blood culture system in which detection is based on measurement of bottle headspace pressure changes. Journal of Clinical Microbiology (1994) 32:1750–1756

    Google Scholar 

  14. Weinstein M, Reller LB, Murphy JR, Lichtenstein KA: The clinical significant of positive blood cultures: A comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I: Laboratory and epidemiological observations. Reviews of Infectious Diseases (1983) 5:35–53

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Elliott, T.S.J., Stevens, C.M., Macrae, F. et al. Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media. Eur. J. Clin. Microbiol. Infect. Dis. 17, 566–569 (1998). https://doi.org/10.1007/BF01708620

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01708620

Keywords

Navigation