Abstract

To investigate the accuracy of the polymerase chain reaction (PCR) method for the detection ofToxoplasma gondii in clinical specimens, aliquots of amniotic fluid to which known amounts ofToxoplasma gondii DNA had been added were tested by five European Centres. Four laboratories were able to detect DNA at levels equivalent to ten tachyzoites or less, including two that detected DNA equivalent to a single parasite. Two laboratories erroneously found one of eight negative control samples to be positive. These findings confirm that the high level of sensitivity associated with the PCR method can be readily achieved under routine laboratory conditions, but they also underscore the potential for both false-positive and false-negative findings to occur. Furthermore, the results confirm the urgent need for an external quality assurance scheme to support laboratories employing PCR in a clinical context for the detection ofToxoplasma gondii.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Grover CM, Thulliez P, Remington JS, Boothroyd JC: Rapid prenatal diagnosis of congenital toxoplasma infection by using polymerase chain reaction and amniotic fluid. Journal of Clinical Microbiology 1990, 28: 2297–2301.

    PubMed  Google Scholar 

  2. Cazenave J, Forestier F, Bessieres MH, Broussin B, Begueret J: Contribution of a new PCR assay to the prenatal diagnosis of congenital toxoplasmosis. Prenatal Diagnosis 1992, 12: 119–127.

    PubMed  Google Scholar 

  3. Dupouy-Camet J, Lavareda de Souza S, Maslo C, Paugam A, Saimot A, Benarous R, Tourte-Schaefer C, Derouin F: Detection ofToxoplasma gondii in venous blood from AIDS patients by polymerase chain reaction. Journal of Clinical Microbiology 1993, 31: 1866–1869.

    PubMed  Google Scholar 

  4. Parmley SF, Goebel FD, Remington JS: Detection ofToxoplasma gondii in cerebrospinal fluid from AIDS patients by polymerase chain reaction. Journal of Clinical Microbiology 1992, 30: 3000–3002.

    PubMed  Google Scholar 

  5. Filice GA, Hitt JA, Mitchell CD, Blackstad M, Sorensen SW: Diagnosis of toxoplasma parasitaemia in patients with AIDS by gene detection after amplification with polymerase chain reaction. Journal of Clinical Microbiology 1993, 31: 2327–2331.

    PubMed  Google Scholar 

  6. Christina N, Pelloux H, Goulhot C, Brion JP, Leclerq P, Ambroise-Thomas P: Detection ofToxoplasma gondii in AIDS patients by the polymerase chain reaction. Infection 1993, 21: 150–153.

    PubMed  Google Scholar 

  7. Roth A, Roth B, Hoffken G, Steuber S, Khalifa Kl, Janitschke K: Application of the polymerase chain reaction in the diagnosis of pulmonary toxoplasmosis in immunocompromised patients. European Journal of Clinical Microbiology & Infectious Diseases 1992, 11: 1177–1181.

    Google Scholar 

  8. Hohlfeld P, Daffos F, Costa J-M, Thulliez P, Forestier F, Vidaud M: Prenatal diagnosis of congenital toxoplasmosis with a polymerase chain reaction test on amniotic fluid. New England Journal of Medicine 1994, 331: 695–699.

    PubMed  Google Scholar 

  9. Pelloux H, Weiss J, Simon J, Muet F, Fricker-Hidalgo H, Goullier-Feuret A, Ambroise-Thomas P: A new set of primers for the detection ofToxoplasma gondii in amniotic fluid using the polymerase chain reaction. FEMS Microbiology Letters 1996, 138: 11–15.

    PubMed  Google Scholar 

  10. Guy EC, Joynson DHM: Potential of the polymerase chain reaction in the diagnosis of active toxoplasma infection by detection of parasite in blood. Journal of Infectious Diseases 1995, 172: 319–322.

    PubMed  Google Scholar 

  11. Zaaijer HL, Cuypers HT, Reesink HW, Winkel IN, Gerken G, Lelie PN: Reliability of polymerase chain reaction for the detection of hepatitis C virus. Lancet 1993, 341: 722–724.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Guy, E.C., Pelloux, H., Lappalainen, M. et al. Interlaboratory comparison of polymerase chain reaction for the detection ofToxoplasma gondii DNA added to samples of amniotic fluid. Eur. J. Clin. Microbiol. Infect. Dis. 15, 836–839 (1996). https://doi.org/10.1007/BF01701532

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01701532

Keywords

Navigation