Abstract
Attention is paid to the character of the resonance frequency time dependence of high precision piezoelectric crystal units of the GT type for a frequency of 100 kHz and of the AT type for a frequency of 2·5 MHz. It is shown that the long-term effect of temperature changes plays an important role in ageing in the initial period.
Similar content being viewed by others
References
Warner A. W., Stockbridge C. D.: Journal of Appl. Phys.34 (1963), 437.
Warner A. W., Fraser D. B., Stockbridge C. D.: Fundamental Studies of Ageing in Quartz Resonators. Proceedings of the International Conference on Chronometry, Lausanne, June 1964.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zelenka, J. A note on the ageing of high precision piezoelectric crystal units. Czech J Phys 16, 437–441 (1966). https://doi.org/10.1007/BF01696254
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01696254