Using thyristor and thyristor-diode a.c. choppers causes distortion of currents and voltages in electrical power networks. In this paper the currents in three-phase, three-wire circuits with thyristor and thyristor-diode a.c. choppers are analysed, making allowances for asymmetrical phase-angle triggering. The computation results of the extinction angles versus firing angles, phase shift angles of the load and degree of asymmetry are shown. The d.c. and harmonic components of the current waveforms were calculated by applying Fourier analysis. The computation results of the magnitudes, which are characteristic of deformed waveforms are also presented.

Übersicht

Der Einsatz von Thyristoren und Thyristordioden verursacht Verzerrungen von Strömen und Spannungen in elektrischen Versorgungsnetzen. In diesem Beitrag werden Stromverläufe in Drehstromnetzen unter Berücksichtigung unsymmetrischer Ansteuerung durch Thyristoren analysiert. Die errechneten Abhängigkeiten des Löschwinkels von der Phasenlage der Last und der Unsymmetrie der Ansteuerung werden dargestellt. Mit Hilfe der Fourieranalyse werden Gleichstromanteil und Oberschwingungen der Ströme ermittelt. Berechnet und dargestellt werden auch andere Größen, die für nichtlinear verzerrte Vorgänge charakteristisch sind.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Shepherd, W.: Steady-state analysis of the series resistance-inductance circuit controlled by silicon controlled rectifiers. IEEE Trans. Ind. Gen. Appl. IGA-1 (1965) 259–265

    Google Scholar 

  2. Michel, M.: Die Strom- und Spannungsverhältnisse bei Steuerung von Drehstromlasten über antiparallele Paare von Thyristoren und Dioden. ETZ-A, 91 (1970) 510 bis 514

    Google Scholar 

  3. Shepherd, W.; Thyristor Control of A.C. Circuits, pp. 225–308, London: Bradford University Press 1976

    Google Scholar 

  4. Broadley, F. C.; Sheppard, J. G.; Shepherd, W.: Steadystate analysis of the series R-L circuit controlled by asymmetrical triggering of thyristors. IEEE Trans. Ind. Appl. IA-9 (1973) 437–447

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Łobos, T., Wordoffa, A. Analysis of three-phase chopper circuits controlled by asymmetrical firing of thyristors. Archiv f. Elektrotechnik 70, 389–399 (1987). https://doi.org/10.1007/BF01574007

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01574007

Keywords

Navigation