Skip to main content
Log in

Cardiac applications of digital subtraction angiography

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Recent developments in digital computer technology have enabled direct digital acquisition of radiographic images at spatial and temporal resolutions similar to that of cineradiography. Initially intended as a means of performing peripheral angiography, digital subtraction angiography has been increasingly applied to cardiac catheterization procedures. Advantages of cardiac digital substraction angiography include the capabilities to: immediately replay, magnify and enhance angiographic studies during coronary artery interventions, perform left ventriculography with peripheral contrast injections and direct left ventriculography with substantially reduced contrast doses, perform bypass graft visualization using aortic root contrast injection, assess relative regional coronary blood flow and facilitate the quantification of ventriculographic and coronary stenosis parameters. Clinical comparisons of standard cineradiographic and digital angiographic studies have demonstrated very similar results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Robb GP, Steinberg I: Visualization of the chambers of the heart, pulmonary circulation, and great blood vessels in man. AJR 1: 1–17, 1938

    Google Scholar 

  2. Frost MM, Fisher HD, Nudelman S, Roehrig H: A digital video acquisition system for extraction of subvisual information in diagnostic medical imaging. Proc SPIE Appl Opt Instrument Med VI, Sept 25–27, Bellingham, WA 127:208–215, 1977

    Google Scholar 

  3. Heintzen PH, Brennecke R, Bursch JH: Automated videoangiographic image analysis. Comp in Cardiol (IEEE) 8: 55–64, 1975

    Google Scholar 

  4. Kruger RA, Mistretta CA, Houk TL, Reiderer SJ, Shaw CB, Goodsitt MM, Crummy AB, Zweibel WZ, Lancaster JC, Rowe GG, Flemming D: Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Radiology 130: 49–57, 1979

    PubMed  Google Scholar 

  5. Wood EH, Sturm RE, Sanders JJ: Data processing in cardiovascular physiology with particular reference to roentgen videodensitometry. Mayo Clin Proc 39: 849–865, 1964

    PubMed  Google Scholar 

  6. Kruger RA, Mistretta CA, Houk TL, Kubal W, Reiderer SJ, Ergun DL, Shaw CB, Lancaster JC, Rowe GG: Computerized fluoroscopy techniques for intravenous study of cardiac chamber dynamics. Invest Radiol 14: 279–287, 1979

    PubMed  Google Scholar 

  7. Drury JK, Gray R, Diamond GA, Whiting J, Pfaff M, Vas R, Wheeler W, Nathan M, Forrester JS: Computer enhanced digital angiography visualizes coronary bypass grafts without need for selective injection. Circulation 66 (Suppl II): II-229, 1982 (abstr)

    Google Scholar 

  8. Tobis J, Nalcioglu O, Iseri L, Johnston WD, Roeck W, Castleman E, Bauer B, Montelli S, Henry WL: Detection and quantitation of coronary artery stenoses from digital subtraction angiograms compared with 35-millimeter film cineangiograms. Am J Cardiol 54: 489–494, 1984

    PubMed  Google Scholar 

  9. Kruger RA: Estimation of the diameter of an iodine concentration within blood vessels using digital radiography devices. Med Phys 8: 652–658, 1981

    PubMed  Google Scholar 

  10. Vogel R, LeFree M, Bates E, O'Neill W, Foster R, Kirlin P, Smith D, Pitt B: Application of digital techniques to selective coronary arteriography: Use of myocardial contrast appearance time to measure coronary flow reserve. Am Heart J 107: 153–164, 1984

    PubMed  Google Scholar 

  11. Bailey NA: Video techniques for x-ray imaging and data extraction from roentgenographic and fluoroscopic presentations. Med Phys 7: 472–491, 1980

    PubMed  Google Scholar 

  12. Kruger RA: Basic physics of computerized fluoroscopy difference imaging. In: Mistretta CA, Crummy AB, Strother CM et al. (eds) Digital subtraction arteriography: An application of computerized fluoroscopy. Yearbook Medical Publishers, Inc, Chicago, 1982, 16–22

    Google Scholar 

  13. Ovitt TW, Fisher HD: Ideal configuration for intravenous digital subtraction angiography machine. Cardiovasc Intervent Radiol 6: 300–302, 1983

    PubMed  Google Scholar 

  14. LeFree MT, Simon SB, Lewis RJ, Bates ER, Vogel RA: Digital radiographic coronary artery quantification. Comput Cardiol, 1985 (in press)

  15. Vogel R, LeFree M, Foster R et al.: Digital left ventriculography: Determination of the benefit from post-acquisition processing. IEEE, Computers in Cardiology, 1982, 219–222

  16. Reiderer SJ, Kruger RA: Intravenous digital subtraction: A summary of recent developments. Radiology 147: 633–638, 1983

    PubMed  Google Scholar 

  17. Robb RA, Wood EH, Ritman EL, Johnson SA, Sturm RE, Greenleaf JF, Gilbert BK, Chevalier PA: Three-dimensional reconstruction and display of the working canine heart and lungs by multiplanar x-ray scanning video densitometry. IEEE Comput Cardiol 151–163, 1974

  18. Brennecke R, Bursch JH, Bogren HG, Heintzen PH: Digital intravenous imaging techniques in pediatric cardiology. In: Mistretta CA, Crummy AB, Strother CM et al. (eds) Digital subtraction arteriography: An application of computerized fluoroscopy. Yearbook Medical Publishers, Inc, Chicago, 1982, 133–141

    Google Scholar 

  19. Reiderer SJ, Enzmann DR, Hall AL, Pelc NJ, Djang WT: The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: Clinical results. Radiology 146: 349–354, 1983

    PubMed  Google Scholar 

  20. Kruger RA: A method for time domain filtering using computerized fluoroscopy. Med Phys 8: 466–469, 1981

    PubMed  Google Scholar 

  21. Kruger RA, Mistretta CA, Crummy AB, Sackett JF, Goodsitt M, Reiderer SJ, Houk TL, Shaw C-G, Flemming D: Digital K-edge subtraction radiography. Radiology 125: 243–45, 1977

    PubMed  Google Scholar 

  22. Ansell G, Tweedie McK, West CR, Evans P, Couch L: The current status of reactions to intravenous contrast media. Invest Radiol 15: S32-S39, 1980

    PubMed  Google Scholar 

  23. Fischer HW: Hemodynamic reactions to angiographic media. Radiology 91: 66–73, 1968

    PubMed  Google Scholar 

  24. Higgins CB: Effects of contrast materials on left ventricular function. Invest Radiol 15: S220-S231, 1980

    PubMed  Google Scholar 

  25. Mancini GBJ, Ostrander DR, Slutsky RA, Shabetai R, Higgins CB: Intravenous vs. left ventricular injection of ionic contrast material: Hemodynamic implications for digital subtraction angiography. Amer J Cardiol 140: 425–430, 1983

    Google Scholar 

  26. Kronenberg MW, Price RR, Smith CW, Robertson RM, Perry JM, Pickens DR, Domanski MJ, Partain CL, Freisinger GC: Evaluation of left ventricular performance using digital subtraction angiography. Am J Cardiol 51: 837–842, 1983

    PubMed  Google Scholar 

  27. Sasayama S, Nonogi H, Kawai C, Eiho C, Kuwahara M: Automated method for left ventricular volume measurement by cineventriculography with minimal doses of contrast medium. Am J Cardiol 48: 746–753, 1981

    PubMed  Google Scholar 

  28. Higgins CB, Gerber KH, Mattrey RA: Evaluation of the hemodynamic effects of intravenous administration of ionic and nonionic contrast materials. Radiology 142: 681–686, 1982

    PubMed  Google Scholar 

  29. Mancini GBJ, Bloomquist JN, Bhargava V, Stein JB, Lew W, Slutsky RA, Shabetai R, Higgins CB: Hemodynamic and electrocardiographic effects in man of a new nonionic contrast agent (iohexol): Advantages over standard ionic agent. Am J Cardiol 51: 1218–1222, 1983

    PubMed  Google Scholar 

  30. Mancini GBJ, Atwood JE, Bhargava V, Slutsky RA, Grover M, Higgins CB: Comparative effects of ionic and nonionic contrast materials on indexes of isovolumic contraction and relaxation in humans. Am J Cardiol 53: 228–233, 1984

    PubMed  Google Scholar 

  31. Sackett JR, Mann FA: Contrast media for digital subtraction arteriography of cerebral arteries. In: Mistretta CA, Crummy AB, Strother CM et al.: Digital subtraction arteriography: An application of computerized fluoroscopy, Yearbook Medical Publishers, Inc, Chicago, 1982, 23–28

    Google Scholar 

  32. Modic MT, Weinstein MA, Pavlicek W, Gallagher J, Duchesneau PM, Buonocore E, Meaney TF: Intravenous digital subtraction angiography: Peripheral versus central injection of contrast material. Radiology 147: 711–715, 1983

    PubMed  Google Scholar 

  33. Saddekni S, Sos TA, Sniderman KW, Srur M, Bodner LJ, Kneeland JB, Cahill PT: Optimal injection technique for intravenous digital subtraction angiography. Radiology 150: 655–659, 1984

    PubMed  Google Scholar 

  34. Eskridge JM, Becker GJ, Rabe FE, Holden RW, Klatte EC: Digital vascular imaging: Practical aspects. Radiology 148: 703–705, 1983

    PubMed  Google Scholar 

  35. Hetzel PS, Swan HJC, Wood EH: Influence of injection site on arterial dilution curves of T-1824. J Appl Physiol 7: 66–72, 1954–1955

    Google Scholar 

  36. Rubin DL, Burbank FH, Bradley BR, Brody WR: An experimental evaluation of central vs. peripheral injection for intravenous digital subtraction angiography (IV-DSA). Invest Radiol 19: 30–35, 1984

    PubMed  Google Scholar 

  37. Nichols AB, Martin EC, Fles TP, Stugensky KM, Balancio LA, Casarella WJ, Weiss MB: Validation of the angiographic accuracy of digital left ventriculography. Am J Cardiol 51: 224–230, 1983

    PubMed  Google Scholar 

  38. Slutsky RA, Mancini GBJ, Norris S, Ashburn WL, Higgins CB: Digital intravenous ventriculography: Comparison of volumes from mask-mode and nonsubtracted images with thermodilution and sonocardiometric measurements. Invest Radiol 18: 327–334

  39. Mancini GBJ, Norris SL, Peterson KL, Gregoratos G, Widmann TF, Ashburn WL, Higgins CB: Quantitative assessment of segmental wall motion abnormalities at rest and after atrial pacing using digital intravenous ventriculography. J Am Coll Cardiol 2: 70–76, 1983

    PubMed  Google Scholar 

  40. Gerber KH, Slutsky RA, Ashburn WL, Higgins CB: Detection and assessment of severity of regional ischemic left ventricular dysfunction by digital fluoroscopy. Am Heart J 104: 27–35, 1982

    PubMed  Google Scholar 

  41. Radtke W, Bursch JH, Brennecke R, Hahne HJ, Meissner L, Heintzen PH: Visualization of the left ventricular wall by digital angiocardiography. Europ Heart J 2: 135–142, 1981

    Google Scholar 

  42. Radtke W, Bursch JH, Brennecke R, Hahne HJ, Heintzen PH: Assessment of myocardial mass and infarction size by digital angiocardiography. In: Heintzen PH, Brennecke R (eds) Digital Imaging in Cardiovascular Radiology. Stuttgart, New York, George Thieme Verlag, 1983, 233–240

    Google Scholar 

  43. Goldberg HL, Borer JS, Moses JW, Fisher J, Cohen B, Skelly NT: Digital subtraction intravenous left ventricular angiography: Comparison with conventional intraventricular angiography. J Am Coll Cardiol 1: 858–862, 1983

    PubMed  Google Scholar 

  44. Nissen SE, Booth D, Waters J, Fassas T, DeMaria AN: Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: Comparison with cineangiography and assessment of interobserver variability. Am J Cardiol 52: 1293–1298, 1983

    PubMed  Google Scholar 

  45. Norris SL, Slutsky RA, Mancini GBJ, Ashburn WL, Gregoratos G, Peterson KL, Higgins CB: Comparison of digital intravenous ventriculography with direct left ventriculography for quantitation of left ventricular volumes and ejection fractions. Am J Cardiol 51: 1399–1403, 1983

    PubMed  Google Scholar 

  46. Tobis JM, Nalcioglu O, Johnston WD, Seibert A, Iseri LT, Roeck W, Elkayam U, Henry WL: Left ventricular imaging with digital subtraction angiography using intravenous contrast injection and fluoroscopic exposure levels. Am Heart J 104: 20–27, 1982

    PubMed  Google Scholar 

  47. Vas R, Diamond GA, Forrester JS, Whiting JS, Swan HJV: Computer enhancement of direct and venous-injected left ventricular contrast angiography. Am Heart J 102: 719–728, 1981

    PubMed  Google Scholar 

  48. Vas R, Diamond GA, Forrester JS, Whiting JS, Pfaff MJ, Levisman JA, Nakano FS, Swan HJC: Computerenhanced digital angiography: Correlation of clinical assessment of left ventricular ejection fraction and regional wall motion. Am Heart J 104: 732–739, 1982

    PubMed  Google Scholar 

  49. Felix R, Eichstadt H, Kempter H, Kewitz A, Banzer D, Schmutzler H, Marhoff P: A comparison of conventional contrast ventriculography and digital subtraction ventriculography. Clin Cardiol 6: 265–276, 1983

    PubMed  Google Scholar 

  50. Kruger RA, Mistretta CA, Reiderer SJ: Physical and technical considerations of computerized transmission fluoroscopy difference image. IEEE Trans Nucl Sci NS-28; 1: 205–212, 1978

    Google Scholar 

  51. Kruger RA: Image data acquisition, processing, storage and display. Cardiovasc Intervent Radiol 6: 183–186, 1983

    PubMed  Google Scholar 

  52. Nalcioglu O, Seibert JA, Boone J, Wang Y, Roeck WW, Henry WL, Tobis JM, Johnston WD: The effect of physical problems on the determination of ventricular ejection fraction by video densitometry. In: Heintzen PH, Brennecke R (eds) Digital Imaging in Cardiovascular Radiology, Stuttgart, New York, George Thieme Verlag, 1983, 104–115

    Google Scholar 

  53. Peppier WW, Van Lysel MS, Dobbins JT, Lancaster JC, Hicks J, Hasegawa BH, Lee CS, Shaikh N, Zarnstorff WC, Mistretta CA, Myerowitz PD, Swanson DK: Progress report on the University of Wisconsin Digital Video Image Processor (DVIP 11). In: Heintzen PH, Brennecke R (eds) Digital Imaging in Cardiovascular Radiology, Stuttgart, New York, George Thieme Verlag, 1983, 56–66

    Google Scholar 

  54. Shaw C-G, Ergun DL, Myerowitz PD, Van Lysel MS, Mistretta CA, Zarnstorff WC, Crummy AB: A technique of scatter and glare correction for videodensitometric studies in digital subtraction videoangiography. Radiology 142: 209–213, 1982

    PubMed  Google Scholar 

  55. Bursch J, Heintzen PH, Simon R: Videodensitometric studies by a new method of quantitating the amount of contrast medium. Eur J Cardiol 1: 437–446, 1974

    PubMed  Google Scholar 

  56. Tobis J, Nalcioglu O, Seibert JA, Johnston WD, Henry WL: Measurement of left ventricular ejection fraction by videodensitometric analysis of digital subtraction angiograms. Am J Cardiol 52: 871–875, 1983

    PubMed  Google Scholar 

  57. Trenholm BG, Winer DA, Reimer GD, Mymin D, Lansdown EL, Sharma GP: Automated ventricular volume calculations from single plane images. Radiology 112: 299–304, 1974

    PubMed  Google Scholar 

  58. Chaitman BR, DeMoto H, Bristow JD, Fosch J, Rahimtoola SH: Objective and subjective analysis of left ventricular angiograms. Circulation 52: 420–425, 1975

    PubMed  Google Scholar 

  59. Engels PHC, Ludwig JW, Verhoeven LAJ: Left ventricular evaluation by digital video subtraction angiography. Radiology 144: 471–474, 1982

    PubMed  Google Scholar 

  60. Bolson EL, Kliman S, Sheehan FH, Dodge HT: Left ventricular segmental wall motion: a new method using local direction information. Comput Cardiol, 1980, p 245

  61. Mancini GBJ, LeFree MT, Vogel RA: Curvature analysis of normal ventriculograms: Fundamental framework for the assessment of shape changes in man. IEEE Comput Cardiol, 1985 (in press)

  62. Tobis JM, Nalcioglu O, Johnston WD, Seibert A, Roeck W, Iseri LT, Elkayam U, Henry WL: Correlation of 10-milliliter digital subtraction ventriculograms compared with standard cineangiograms. Am Heart J 105: 946–952, 1983

    PubMed  Google Scholar 

  63. Seldin DW, Esser PD, Nichols AB, Ratner SJ, Alderson PO: Left ventricular volume determined from scintigraphy and digital angiography by a semi-automated geometric method. Radiology 149: 809–813, 1983

    PubMed  Google Scholar 

  64. Goldberg HL, Moses JW, Borer JS, Fisher J, Tamari I, Skelly NT, Cohen B: Exercise left ventriculography utilizing intravenous digital angiography. J Am Coll Cardiol 2: 1092–1098, 1982

    Google Scholar 

  65. Detrano R, Simpfendorfer C, Day K, Salcedo E, Rincon G, Kramer JR, Hobbs RE, Shirey EK, Rollins M, Sheldon WC: Comparison of stress digital ventriculography, stress thallium scintigraphy, and digital fluoroscopy in the diagnosis of coronary artery disease in subjects without prior myocardial infarction. Am J Cardiol 56: 434–440, 1985

    PubMed  Google Scholar 

  66. Tobis J, Nalcioglu O, Johnston WD, Seibert A, Iseri LT, Roeck W, Henry WL: Digital angiography in assessment of ventricular function and wall motion during pacing in patients with coronary artery disease. Am J Cardiol 51: 668–675, 1983

    PubMed  Google Scholar 

  67. Mancini GBJ, Peterson KL, Gregoratos G, Higgins CB: Effects of atrial pacing on global and regional left ventricular function in coronary heart disease assessed by digital intravenous ventriculography. Am J Cardiol 53: 456–461, 1984

    PubMed  Google Scholar 

  68. Johnson RA, Wasserman AG, Leibhoff RH, Katz RJ, Bren GB, Varghese J, Ross AM: Intravenous digital left ventriculography at rest and with atrial pacing as a screening procedure for coronary artery disease. J Am Coll Cardiol 2: 905–910, 1983

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vogel, R.A., Mancini, G.B.J. & Bates, E.R. Cardiac applications of digital subtraction angiography. Int J Cardiac Imag 1, 233–240 (1985). https://doi.org/10.1007/BF01568671

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01568671

Keywords

Navigation