Skip to main content
Log in

Dielectric behavior of polychloroprene

  • Originalarbeiten
  • Polymere
  • Published:
Kolloid-Zeitschrift und Zeitschrift für Polymere Aims and scope Submit manuscript

Summary

The dielectric measurement of polychloroprene (PCP) over the range of 1 c/s ∼ 1 Mc/s and −100 °C ∼ 20 °C gave high temperature absorption (αaabsorption) and low temperature absorption a -absorption). In order to clarify the relationship between the dielectric behavior and the chemical structure, the result of PCP was compared with that of polyvinylchloride (PVC). The apparent activation energy of the α a - or the β a -absorption of PCP was much smaller than that of the corresponding absorption of PVC. Each absorption of PCP is located at much lower temperatures and higher frequencies than the corresponding one of PVC. These results are interpreted to be due to the smaller concentration of bulky chlorine atom and the existence of double bond in PCP. The shape of α a -absorption curve of PVC was as sharp as that of PVC at the temperature range much higher than each glass transition temperature. The shape of β a -absorption curve of PCP was as broad as that of PVC at temperatures much lower than each glass transition temperature. The magnitude of absorption of PCP is much smaller than that of PVC in either of the α a - and the β a -absorption. This is due to the smaller concentration of chlorine atom in PCP.

Zusammenfassung

Die dielektrische Untersuchung von Polychloropren (PCP) über den Bereich von 1 Hz bis 1 MHz und −100 °C bis 20 °C gab Absorptionen bei hoher Temperatur (α a -Maximum) und Absorption bei niederer Temperatur (β a -Maximum). Um die Beziehungen zwischen dem dielektrischen Verhalten und der chemischen Struktur zu klären, wurde das Ergebnis von PCP verglichen mit dem von Polyvinylchlorid (PVC). Die scheinbare Aktivierungsenergie der α a - oder der β a -absorption von PCP war viel kleiner als die von der entsprechenden Absorption von PVC. Die Absorptionen von PCP liegen beide bei wesentlich tieferen Temperaturen und höheren Frequenzen als die entsprechenden von PVC.

Diese Ergebnisse wurden interpretiert auf Grund der geringeren Konzentration des voluminösen Chloratoms und der Existenz der Doppelbindung in PCP. Die Form der αa-Absorptionskurve von PVP war ebenso scharf wie die von PVC in einem Temperaturbereich viel höher als die Glasumwandlungstemperatur. Die Gestalt der α a -Absorptionskurve von PCP war ebenso breit wie die von PVC bei viel tieferen Temperaturen als der betreffenden Glasumwandlungstemperatur. Die Größe der Absorption von PCP ist viel kleiner als die von PVC, sowohl für die α a -als die β a -Absorption. Dies ist der geringeren Konzentration von Chloratomen in PCP zuzuschreiben.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Iahida, Y., Kolloid-Z. 168, 29 (1960).

    Article  Google Scholar 

  2. Schneider, W. C., W. C. Carter, M. Magat, and C. P. Smyth, J. Amer. Chem. Soc. 67, 959 (1945).

    Article  CAS  Google Scholar 

  3. Mack, E., J. Amer. Chem. Soc. 56, 2757 (1934).

    Article  CAS  Google Scholar 

  4. Ishida, Y., K. Yamafuji, and M. Matsuo, Kolloid-Z. u. Z. Polymere 180, 108 (1962).

    Article  CAS  Google Scholar 

  5. Ishida, Y. and K. Yamafuji, Kolloid-Z. u. Z. Polymere 177, 97 (1961).

    CAS  Google Scholar 

  6. Ishida, Y., K. Yamafuji, H. Ito. and M. Takayanagi, ibid. 184, 97 (1962).

    Article  CAS  Google Scholar 

  7. Cole, K. S. and R. H. Cole, J. Chem. Phys. 9, 341 (1941).

    Article  CAS  Google Scholar 

  8. Yamafuji, K. and Y. Ishida, Kolloid-Z. u. Z. Polymere 183, 15 (1962).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Matsuo, M., Ishida, Y., Yamafuji, K. et al. Dielectric behavior of polychloroprene. Kolloid-Z.u.Z.Polymere 201, 89–93 (1965). https://doi.org/10.1007/BF01520489

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01520489

Keywords

Navigation