In a comparison of the filtration methods of Reid et al. and Schmid-Schönbein et al., the significance of other formed blood elements for the assessment of red cell deformability is established. The hydrodynamic measurements and the morphological inspection of the sieves show the interference of red cell pore passage by thrombozyte aggregates and white blood cells (which were not further identified).

In light of these findings, which have since been corroborated by other groups, it is mandatory to remove all cellular blood elements exept the red cells in filtration test of the latter. Lowering the hematocrit improves the reliability of the test. The whole blood filtrationtest, popular because of its simplicity, cannot be standardized and yields results of questionable relevance.

Zusammenfassung

Durch Vergleich der Filtrationsmethoden von Reid und Schmid-Schönbein wurde die Bedeutung der sonstigen korpuskulären Elemente des Blutes für die Erfassung der Verformbarkeit von Erythrozyten festgestellt. Hydrodynamische Messungen und morphologische Inspektion der Siebe demonstrieren den Störeffekt der Leukozyten (nicht näher identifiziert) und der Thrombozytenaggregate auf den Passagevorgang der Erythrozyten durch die Pore.

Angesichts dieser Befunde, die auch von anderen Gruppen bestätigt wurden, ist es unerläßlich, daß die anderen zellulären Blutbestandteile sorgfältig eliminiert werden müssen, ehe im Filtrationstest die Erythrozytenverformbarkeit abgeschätzt wird. Die Erniedrigung des Hämatokritwertes erhöht die Verläß-lichkeit, da der Fließvorgang gleichmäßiger abläuft. Der Vollblutfiltrationstest, der sich derzeit wegen seiner einfachen Handhabung großer Beliebtheit erfreut, kann ohne die o.g. präparativen Maßnahmen nicht standardisiert werden und ergibt Befunde von fraglicher Relevanz.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Aspelin P, Schmid-Schönbein H (1977) Effect of ionic and non-ionic contrast media on blood rheology. Bibl Anat 16:517–521

    Google Scholar 

  2. Boyum A (1968) Separation of leucocytes from blood and bone marrow. Scand J Clin Lab Invest 21:[Suppl] 97

    Google Scholar 

  3. Chien S (1977) Principles and technique for stressing erythrocyte deformability. Blood Cells 3:71–99

    Google Scholar 

  4. Grigoleit HG, Jacobi G (1977) Microrheological effects of the vasoactive compound 3.7 Dimethyl-1-(5-oxohexyl)-xanthine (Pentoxifylline, BL 191). Vasa 6:274–278

    Google Scholar 

  5. Jandl HJ, Simmons RL, Castle WB (1961) Red cell filtration and the pathogenesis of certain haemolytic anemias. Blood 18:133–148

    Google Scholar 

  6. Leonhardt, H, Reinhardt I (1977) Methodische Untersuchungen zur Messung der Erythrozytenverformbarkeit (Filtrabilität, Flexibilität, Fluidität) in Abhängigkeit von der Plasmaviskosität, den Plasmaproteinen, des Hämatokrit, des Filtrationsdrukkes sowie der Osmolarität. Experientia 33:179–181

    Google Scholar 

  7. Lessin LS, Kurantsin-Mills J, Weems HB (1977) Deformability of normal and sickle erythrocytes in a pressure-flow filtrations system. Blood Cells 3:241–262

    Google Scholar 

  8. Lichtman MA, Kearney EA (1976) The filterability of normal and leukemic human leukocytes. Blood Cells 2:491–506

    Google Scholar 

  9. Lingard PS (1974) Capillary pore rheology of erythrocytes I. Hydroelastic behaviour of human erythrocytes. Microvasc Res 8:53–63

    Google Scholar 

  10. Ludwig H, Metzger H (1976) The human female reproductive tract. Springer, Berlin Heidelberg New York

    Google Scholar 

  11. Moll W (1963) Parameters of oxygen transport. In: Lasch HG, Heene DL (eds) Microcirculation, haemostasis and shock. Schattauer, Stuttgart

    Google Scholar 

  12. Nakao M, Nakajamo TN, Konkura T (1973) A new method for separation of human blood components. Nature 246:94

    Google Scholar 

  13. Reid HL, Barnes AI, Lock PJ, Dormandy JA, Dormandy TL (1976) A simple method for measuring erythrocyte deformability. J Clin Pathol 29:855–858

    Google Scholar 

  14. Schmid-Schönbein H, Weiss J, Ludwig H (1973) A simple method for measuring red cell deformability in models of the microcirculation. Blut 26:369–379

    Google Scholar 

  15. Usami S, Chien S, Bertels JF (1975) Deformability of sickle cells as studied by microsieving. J Lab Clin Med 86:274–279

    Google Scholar 

  16. Zander R, Schmid-Schönbein H (1972) Red cell rheology and oxygen transport. In: Messmer K, Schmid-Schönbein H (eds) Haemodilution. Theoretical basis and clinical application. Karger, Basel

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Mit Unterstützung der DFG He 1010/3

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heilmann, L., Schmid-Schönbein, H. Ein methodischer Beitrag zur Messung der Erythrozytenverformbarkeit. Klin Wochenschr 59, 181–185 (1981). https://doi.org/10.1007/BF01477478

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01477478

Key words

Schlüsselwörter

Navigation