Summary
CBF determination can provide additional valuable information which can be used in clinical practice to enhance our capabilities in patient evaluation. The initial techniques requiring intraarterial injections have been largely replaced by the noninvasive inhalation and intravenous methods. The recent refinement of microcomputers and the development of portable CBF monitors have made CBF determination a nontraumatic, dependable and easily repeatable examination at the patient's bedside. In this communication we compare a portable region CBF monitor and a portable mean hemispheral CBF monitor; we study their advantages and disadvantages in clinical practice. Emphasis is placed on the practical characteristics and the information provided by each monitor and its contribution to patient evaluation. Illustrative cases are presented.
Similar content being viewed by others
References
Ferguson, G. G., Harper, A. M., Fitch, W.,et al., Cerebral blood flow measurements after spontaneous subarachnoid haemorrhage. Eur. Neurol.8 (1972), 15–22.
Grubb, R. L., Raichle, M. E., Eichling, J. O.,et al., Effects of subarachnoid haemorrhage on crebral blood volume, blood flow and oxygen utilisation in humans. J. Neurosurg.46 (1977), 446–453.
Heilbrun, M. P., Olesen, J., Lassen, N. A., Regional cerebral blood flow studies in subarachnoid haemorrhage. J. Neurosurg.37 (1972), 36–44.
Kety, S. S., Schmidt, C. F., The determination of cerebral blood flow in man by the use of nitrous oxide in low concentrations. Lancet2 (1961), 806–807.
Obrist, W., Thompson, H., Jr., Wang, H. H., Regional cerebral blood flow estimated by133Xenon inhalation. Stroke6 (1975), 245–255.
Risberg, J., Ali, Z., Wilson, E.,et al., Regional cerebral blood flow by133Xenon inhalation. Stroke6 (1975), 142–148.
Risberg, J., Regional cerebral blood flow measurements by 133-Xenon inhalation: Methodology and applications in neuropsychology and psychiatry. Brain and Language9 (1980), 9–34.
Rosenstein, J., Suzuki, M., Symon, L., Clinical use of a portable bedside cerebral blood flow machine in the management of aneurysmal subarachnoid haemorrhage. Neurosurgery15 (1984), 519–525.
Symon, L., Ackerman, R., Bull, J.,et al., The use of the Xenon clearance method in subarachnoid haemorrhage. Eur. Neurol.8 (1972), 8–14.
Thomas, D. J., Zilkha, E., Redmond, S.,et al., An intravenous133Xenon clearance technique for measuring cerebral blood flow. J. Neurol. Sci.40 (1979), 53–63.