Summary
Due to its capability of producing a well localized intense heat field of predictable dimensions, the electromagnetic field focusing probe was evaluated experimentally as a surgical tool in aneurysm thrombosis. Aneurysm models were created by anastomosing a segment of vein to the abdominal aorta. Seventy-five such aneurysms were created in seventy-five animals. The aneurysms were then placed under the solenoidal radiofrequency coil and the tip of the field focusing probe was inserted into them. Intense heat was delivered with well defined, effective and quick thrombosis and shrinkage of the aneurysm. Nineteen of the aneurysms were followed for up to one week. Histological studies were conducted showing complete thrombosis of the aneurysm with good preservation of the aorta. With further refinement of this technique, it is hoped that stereotaxic aneurysm thrombosis might be possible.
Similar content being viewed by others
References
Alksne JF, Smith RW (1977) Iron-acrylic compound for stereotaxic aneurysm thrombosis. J Neurosurg 47: 137–141
Aronow S (1960) The use of radiofrequency power in making lesions in the brain. J Neurosurg 17: 431–438
Boddie AW, Yamanashi WS, Frazer JW, McBride CM, Martin RG (1983) Field focusing and focal heating patterns in solid phantoms using a hybrid radiofrequency systems of novel design. Med Instrum 17: 358–364
Bonin GV, Alberts WW, Wright EW, Feinstein B (1965) Radiofrequency brain lesions. Arch Neurol 12: 25–29
Bowman HF (1980) Heat transfer mechanism and thermal dosimetry. Proc. 3rd International Symposium: Cancer Therapy by Hyperthermia. Fort Collins, Colorado, pp 437–444
Debrun G, Lacour P, Caron JP, Hurth M, Comoy J, Keravel Y (1978) Detachable balloon and calibrated-leak balloon techniques in the treatment of cerebral vascular lesions. J Neurosurg 49: 635–649
Gianturco C, Anderson JH, Wallace S (1975) Mechanical device for arterial occlusion. Am J Roentgenol 124: 428–435
Guy AW, Webb MD, McDougall JA (1976) Critical comparison of RF field delivery method to thermal responses of models and experimental animals. USAF/SAM contract. F41609-75-C-0021, Final Report
Heifetz MD, Heishima GB, Mehringer CM (1980) Preliminary report of a hollow-centered balloon for intravascular occlusion of intracranial aneurysms or arteriovenous fistulas-Technical note. J Neurosurg 53: 262–265
Neuder SM (1978) Electromagnetic fields in biological media. Part I: Dosimetry-a primer on bioelectromagnetics, HEW publication [FDA] 78–8068, pp 1–21
Patil AA, Nagaraj MP (1984) Recoiling suture and methylmethacrylate in aneurysm thrombosis-preliminary report. Acta Neurochir (Wien) 72: 73–78
Smith RW, Alksne JF (1977) Stereotaxic thrombosis of inaccessible intracranial aneurysms. J Neurosurg 47: 833–839
Tadavarthy SM, Moller JH, Amplatz K (1975) Polyvinyl alcohol (ivolon) a new embolic material. Am J Roentgenol 125: 609–616
Yamanashi WS, Boddie AW, Frazer JW, McBride CM, Martin RG (1984) Further observations on tissue heating patterns using an invasive ground probe with radiofrequency hyperthermia system. Med Instrum 18: 200–223
Yamanashi WS, Fesen MR, Anderson DW, Valentine JL, Sy AM, Crandall CR, Lester PD (1984) Focused hyperthermia with a magnetic resonance imaging (MRI) unit and an interstitial grounded probe. Physiol Chem Phys Med NMR 16: 491–498
Yamanashi WS, Fesen MR, Anderson DW, Sy MS, Lester PD (1985) Field focusing hyperthermia and magnetic resonance imaging (MRI) with a grounded probe and a commercial MRI scanner. Med Instrum 19: 217–223
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Patil, A.A., Yamanashi, W., Valentine, J. et al. Electromagnetic field focusing (EFF) probe in aneurysm thrombosis. Acta neurochir 81, 68–71 (1986). https://doi.org/10.1007/BF01456267
Issue Date: