Summary
A comparison was carried out between 3 computer-assisted systems for the estimation of DNA fragment length: (1) the “Digitab” system (developed at our institute), (2) the FBI analysis system (FBI Quantico, USA) and (3) the BioImage system (Waters/Millipore, USA). Both the FBI system and the Biolmage system were found to be much more precise than the manual Digitab system. In an additional experiment, a possible influence of the field strength on the “accuracy” of fragment size measurement was checked. Lowering the field strength to approx. 1 V/cm led to a statistically significant increase in the measured fragment size.
Zusammenfassung
Drei computer-unterstützte Systeme zur DNA-Fragmentlängenbestimmung wurden verglichen: (1) Das „Digitab-System” (entwickelt im Institut für Rechtsmedizin, Münster, FRG), (2) das „FBI-Analysis-System” (FBI, Quantico, USA) und (3) das Biolmage-System (Waters/Millipore, USA). Das FBI-Analysis-System und das BioImage-System arbeiteten präziser als das halbautomatische Digitab-System. In einem zusätzlichen Experiment wurde der mögliche Einfluß der Feldstärke auf die „Richtigkeit” der Fragmentlangenbestimmung untersucht. Eine Reduzierung der Feldstärke auf etwa 1 V/cm führte zu signifikant höheren Werten bei der Fragmentlängenbestimmung.
Similar content being viewed by others
References
Brinkmann B (1991) Quality control in DNA investigations" Results of blind trials in Europe. In: Proceedings from The Second International Symposium on Human Identification 1991 - New technologies, standardization of methods, and data sharing for DNA typing laboratories, Promega Corporation: 211–224
Brinkmann B, Rand S, Wiegand P (1991) Population and family data of RFLPs using selected single and multi locus systems. Int J Leg Med 104:81–86
Brunk CF, Jones KC, James TW (1979) Assay nanogram quantities of DNA in cellular homogenates. Anal Biochem 92:497–500
Elder JK, Southern EM (1987) Computer-aided analysis of one dimensional restriction fragment gels. In: Bishop MJ, Raulings C (eds) Nucleic acid and protein sequence analysis. IRL Press, Oxford, pp 165–172
Feinberg AP, Vogelstein B (1983) A technique for radiolabelling DNA restriction endonuclease fragments to high specific activity. Anal Biochem 132:6–13
Fisher MP, Dingman CW (1971) Role of molecular conformation in determining the electrophoretic properties of polynucleotides in agarose-acrylamide composite gels. Biochemistry 10:1895
Gill P, Jeffreys AJ, Werrett DJ (1985) Forensic application of DNA ‘fingerprints’. Nature 318:577–579
Gill P, Woodroffe S, Bär W, Brinkmann B, Carracedo A, Eriksen B, Jones S, Kloosterman AD, Ludes B, Mevag B, Pascali VL, Schmitter H, Schneider PM, Thomson JA (1992) The second EDNAP exercise - An international collaborative experiment to demonstrate uniformity of DNA profiling technique. Int J Forensic Sci 53:29–43
Jeffreys AJ, Wilson V, Thein SL (1985) Hypervariable ‘minisatellite’ regions in human DNA. Nature 314:67–73
Monson KL (1988) Semiautomated analysis of DNA autoradiograms. Crime Laboratory Digest 15:104–105
Nakamura Y, Leppert M, O'Connell P, Roger W, Holm T, Culver M, Martin C, Fujimoto E, Hoff M, Kumlin E, White R (1987) Variable number of tandem repeat (VNTR) markers for human gene mapping. Science 235:1616–1621
Puers C, Rand S, Brinkmann B (1991) Concept for a more precise definition of the polymorphism YNH24. In: Berghaus G, Brinkmann B, Rittner C, Staak M (eds) DNA-technology and its application. Springer, Berlin Heidelberg NewYork, pp 109–115
Puers C, Brinkmann B (1992) Grundlagen der DNA-Fragmentlängenbestimmung in der Forensischen Analyse. Rechtsmedizin 2:47–54
Sambrook J, Fritsch EF, Maniatis T (1989) Molecular cloning: a laboratory manual. Cold Spring Harbor Laboratory Press, NewYork, pp 1–3
Schaffer HE, Sederoff RR (1981) Improved estimation of DNA fragment length from agarose gels. Anal Biochem 115:113–122
Schneider PM, Fimmers R, Woodroffe S, Werrett DJ, Bär W, Brinkmann B, Eriksen B, Jones S, Kloosterman AD, Mevag B, Pascali VL, Rittner C, Schmitter H, Thomson JA, Gill P (1991) Report of a European collaborative exercise comparing DNA typing results using a single locus VNTR probe. Forensic Sci Int 49:1–15
Southern EM (1975) Detection of specific sequences among DNA fragments separated by gel electrophoresis. J Mol Biol 98:503–517
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Puers, C., Wiegand, P. & Brinkmann, B. Some technical parameters influencing the precision and accuracy of fragment size determination for RFLP's. Int J Leg Med 105, 31–34 (1992). https://doi.org/10.1007/BF01371234
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01371234