Conclusions
Special periclase-spinel brick OPShS with a high content of finely ground Kimpersai chromite and no magnesite in the finely ground part of the batch, used in roofs of large open-hearth furnaces, working in oxygen fed into the flame and into the bath, showed greater wear than PShS brick and about the same wear as MKhS.
Rational periclase-spinel roof brick RPShS tested for the first time at MTMK showed encouraging results in regard to wear resistance.
Roofs of periclase-spinel brick made in one case from Saranov and in the other from Kimpersai chromite, in identical conditions of production and service, did not reveal great differences in resistance.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
N. N. Baranova, E. K. Kozhevnikova, A. P. Kukushkin, and E. A. Sagatulina took part in the work.
Rights and permissions
About this article
Cite this article
Vydrina, Z.A., Panarin, A.P. & Uzberg, A.I. Testing periclase-spinel brick in the roofs of open-hearth furnaces. Refractories 4, 226–231 (1963). https://doi.org/10.1007/BF01370975
Issue Date:
DOI: https://doi.org/10.1007/BF01370975