Skip to main content
Log in

Incisor torque by means of a modified Teuscher activator

Three case reports

Torquen oberer Schneidezähne mit Hilfe eines modifizierten Teuscher-Aktivators

Drei Fallberichte

  • Original Contributions
  • Published:
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie Aims and scope Submit manuscript

Abstract

It is generally accepted that in the treatment of Class II, 1 malocclusion classical activators may tip the upper incisors considerably. In comparison, in the cases described, an even better torque control was obtained. It has been our clinical experience that with the modified Teuscher activator it is possible to control upper incisor inclination and in some cases it is even possible to induce active palatal root torque. The appliance is relatively comfortable with good vertical retention even without headgear.

Zusammenfassung

Es wird allgemein akzeptiert, daß bei der Behandlung von Klasse-II, 1-Abweichungen klassische Aktivatoren die oberen Inzisivi erheblich nach palatinal kippen können. Wir konnten die klinische Erfahrung machen, daß es mit dem modifizierten Teuscher-Aktivator möglich ist, die Achsenneigung der oberen Inzisivi unter Kontrolle zu halten, und in einigen Fällen gelang es sogar, aktiv einen palatinalen Wurzeltorque zu bewirken. Der Tragekomfort des Gerätes ist relativ gut, mit guter vertikaler Retention, sogar ohne Headgear.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Aelbers CMF, Dermaut L. Orthopedics in orthodontics: fiction or reality? Part I. Am J Orthodont Dentofac Orthop 1996;110: 513–9.

    Google Scholar 

  2. Bass NM. Early treatment of skeletal II malocclusion involving preliminary incisor root torquing. Trans Europ Orthodont Soc 1975;1:191–200.

    Google Scholar 

  3. Beek H van. Overjet correction by a combined headgear and activator. Eur J Orthodont 1982;4:279–90.

    Google Scholar 

  4. Beek H van Combination headgear activator. J Clin Orthodont 1984;18:185–9.

    Google Scholar 

  5. Dermaut LR, Aelbers C. Orthopedics in orthodontics: fiction or reality? A review of the literature. Part II. Am J Orthodont Dentofac Orthop 1996;110:667–71.

    Google Scholar 

  6. Dermaut LR, Eynde F van den, De Pauw G. Skeletal and dento-alveolar changes as a result of headgear activator therapy related to different vertical growth patterns. Eur J Orthodont 1992;14:140–6.

    Google Scholar 

  7. Stöckli PW, Teuscher U. Combined activator headgear orthopedics. In: Graber TM, Swain B, eds. Orthodontics: current principles and techniques. St. Louis-Toronto-Princeton: Mosby, 1985:405–83.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aelbers, C., Dermaut, L. Incisor torque by means of a modified Teuscher activator. J Orofac Orthop/Fortschr Kieferorthop 59, 171–177 (1998). https://doi.org/10.1007/BF01317178

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01317178

Key Words

Schlüsselwörter

Navigation