Skip to main content
Log in

Fire endurance of lightweight wood trusses in building construction

  • Technical Note
  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

Lightweight wood trusses are economical construction elements that combine high strength, light weight, and cost savings. The parallel-chord truss is one of the most common lightweight trusses used in commercial and residential occupancies today. Like all structural components, these trusses are arguably susceptible to failure when exposed to fire. This paper will address fire resistance concerns of parallel-chord, lightweight wood truss floor- and roof-ceiling assemblies, particularly their performance under fire conditions and their susceptibility to construction defects. Because evaluating the effect of fire exposure on both conventional and lightweight wood truss assemblies is so important, considerable supplemental background information on the standard fire test, as it applies to general types of construction, is also provided.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. National Fire Protection Association, Quincy, Mass.

  2. Orange County Fire and Rescue Division Investigation Team, “Orange County Fatal Fire Investigation and Analysis,”Fire Engineering, July 1989.

  3. Kurzeja, Walter, “Lightweight Wood Truss Construction Gives Up More Lessons,”Fire Engineering, March 1989.

  4. Eisner, Harvey, “New Jersey's Darkest Hour,”Firehouse, September 1988.

  5. “Commentary and Recommendations for Bracing Wood Trusses,”Publication BWT-76, Truss Plate Institute, Madison, Wisc., 1976.

  6. “Commentary and Recommendations for Handling and Erecting Wood Trusses,”Publication HET-80, Truss Plate Institute, Madison, Wisc., 1980.

  7. ASTM E-119,Standard Method of Test for Fire Endurance of Construction and Materials, American Society for Testing and Materials, Philadelphia, Pa., 1983.

    Google Scholar 

  8. SFPE Handbook of Fire Protection Engineering, Society of Fire Protection Engineers, Boston, Mass., 1988, pp. 3 to 90.

  9. Second Moment Reliability Analysis of Fire Exposed Wood Joist Floor Assemblies, USDA Forest Service, Forest Products Laboratory, Madison, Wisc., 1979.

  10. “Reliability Analysis of Fire Exposed Light-Frame Wood Floor Assemblies,”Research Paper FPL386, USDA Forest Products Laboratory, Madison, Wisc., January 1981.

  11. Thompson, H. E.,The Fire Performance of Timber, Canadian Institute of Timber Construction, Ottawa, Canada, 1957.

    Google Scholar 

  12. Malhotra, H. L., and Rogowski, B. F., “Fire Resistance of Laminated Timber Columns,”Research Report Digest No. 13, Committee on Research and Technology, Fire Research Station, Borhamwood, Herts, England, September 1967.

    Google Scholar 

  13. “Review of Information Relating to the Charring Rate of Wood,”Research Note FPL0145, USDA Forest Service, Forest Products Laboratory, Madison, Wisc., November 1966.

  14. “Thermal Degradation of Wood Components: A Review of the Literature,”Research Paper FPL130, USDA Forest Service, Forest Products Laboratory, Madison, Wisc., May 1970.

  15. Lawson, D. I., Webster, C. T., and Ashton, L. A.,The Fire Endurance of Timber Beams and Floors, read before the Institution of Structural Engineers, London, 1952.

    Google Scholar 

  16. SFPE Handbook of Fire Protection Engineering, Society of Fire Protection Engineers, Boston, Mass., 1988, pp. 3 to 133.

  17. Ruth, Julie, P.E.,Metal-Plate-Connected Truss Systems—A Code Analysis, Building Official and Code Administrator, January/February 1990.

  18. Report on Wood Truss Members with Steel Plate Connectors Used in Floor/Ceiling Assemblies, Underwriters Laboratories, Inc., Northbrook, Ill., February 2, 1981.

  19. Fire Resistance Directory, Underwriters Laboratories, Inc., Northbrook, Ill., 1990.

  20. Fire Test FC214,1-Hour, Floor Ceiling Assembly Wood Truss with Plywood Floor and Gypsum Wallboard Ceiling, Factory Mutual Research Corporation, Norwood, Mass., July 6, 1978.

    Google Scholar 

  21. ASTM E-119,Fire Endurance Test of Wood-Webbed Truss Floor-Ceiling Assembly, Design FC392,1-Hour, PFS Test Report No. 86-10 PFS, Testing Laboratory, Madison, Wisc., March 18, 1986.

    Google Scholar 

  22. Improved Fire Safety Design of Firestopping and Draftstopping for Concealed Spaces, Technical Services Division, National Forest Products Association, Washington, D.C., 1984.

  23. Uniform Building Code, International Conference of Building Officials, 1991.

  24. NFPA 13, Standard for the Installation of Automatic Sprinkler Systems, National Fire Protection Association, 1989.

  25. Lougheed, G. D., and Richardson, J. K., “Sprinklers in Combustible Concealed Spaces,”Journal of Fire Protection Engineering, Institute for Research in Construction, National Research Council of Canada, Volume 1, No. 2 (April, May, June 1989).

  26. Brannigan, Francis L., “A Primer on Truss Roofs—Why Truss Roofs Are Hazardous for Fire Fighters,”Firehouse, March 1989.

  27. Davis, Mark E., “Vent Steel Truss Roofs Carefully,”Fire Service Today, July 1983.

  28. National Fire Protection Association, Quincy, Mass.

  29. Schaffer, E. L., "Charring Rate of Selected Woods—Transverse to Grain,"USDA Forest Service Research Paper FPL 69, Madison, Wisc., 1967.

  30. White, R. H.,Charring Rate of Different Wood Species, Ph.D. dissertation, University of Wisconsin, Madison, Wisc., 1988.

    Google Scholar 

  31. White, R. H., and Nordheim, E. V., "Charring Rate of Wood for Astm E-119 Exposure,"Fire Technology, Volume 28, Number 1 (1992), pp. 5 to 30.

    Google Scholar 

  32. White, R. H., Schaffer, E. L., Woeste, F. E., "Replicate Fire Endurance Tests of an Unprotected Wood Joist Floor Assembly,"Wood and Fiber, Volume 16, Number 3 (1984), pp. 374 to 390.

    Google Scholar 

  33. “Connectors for Wood Construction,”Product and Instruction Manual, Simpson Strong—Tie Company, Inc., San Leandro, Calif., 1989.

  34. Case History: Plywood and Rigid Frames Figure in New Clear—Span Design, General Construction, American Plywood Association, Tacoma, Wash.

  35. Tuomi, R. L., ASTM STP 702, Full-Scale Testing of Wood Structures, Full-Scale Load Testing of Structures, American Society for Testing and Materials, Philadelphia, Pa., 1980, pp. 45 to 62.

    Google Scholar 

  36. Case History: Truss Joist and Plywood—An Efficient School Roof System, American Plywood Association, Tacoma, Wash.

  37. ASTM C36-85,Standard Specification for Gypsum Wallboard, American Society for Testing and Materials, Philadelphia, Pa., 1988.

    Google Scholar 

  38. “Commentary on Load Duration Effects for Wood,”Truss Plate Institute Newsletter, Truss Plate Institute, Madison, Wisc., January 30, 1978.

  39. Model Building Codes—Update Guide to Wood Frame Constructions, Western Wood Products Association, Portland, Ore., 1989.

  40. Bletzacker, Richard W., P.E., “What Load Did You Use on That Wood-Framed Fire Test Assembly?,”Southern Building Code Congress International Newsletter.

  41. Design for Code Acceptance, Design of Fire-Resistive Exposed Wood Members, National Forest Products Association, Washington, D.C.

  42. Fire Facts, American Institute of Timber Construction, Washington, D.C.

  43. “What About Fire?,”The Spectator, Factory Insurance Association (now IRI), October 1953.

  44. Mittendorf, John, “Joist Rafter vs. Lightweight Wood Truss,” Fire Engineering, July 1988.

  45. Brannigan, Francis L., “Beware the Truss,”Fire Engineering, August 1985.

  46. Timoney, Tom, “Texas Plywood Manufacturing Plant Destroyed,”Fire Journal, March 1985.

  47. Corbett, Glenn P., “Lightweight Wood Truss Floor Construction: A Fire Lesson,”Fire Engineering, July 1988.

  48. Schaffer, Erwin L., P.E., Ph.D., “How Well Do Wood Trusses Really Perform During a Fire?,”Fire Journal, March/April 1988.

  49. “Comparative Fire Test on Wood and Steel Joists,”Technical Report No. 1, National Forest Products Association, Washington, D.C., 1961.

  50. “Comparative Fire Test of Timber and Steel Beams,” Technical Report No. 3, National Forest Products Association, Washington, D.C.

  51. APA Design/Construction Guide: Non-Residential Roof Systems, American Plywood Association, Tacoma, Wash., 1988.

  52. Building Materials Directory, Underwriters Laboratories, Northbrook, Ill., 1990.

  53. Conversation with Roland Bellman, P.E., Senior Consulting Engineer, Rolf Jensen and Associates, Inc., Deerfield, Ill.

  54. “Lightweight Wood Truss Legislation,”Fire Engineering, February 1991.

  55. Fire News, National Fire Protection Association, Quincy, Mass.

  56. Product Use Manual No. 6, Western Wood Products Association, Portland, Ore., 1988.

  57. ICBO Building Code Case Study—Multi Story Wood-Frame No. 1, Western Wood Products Association, Portland, Ore., 1989.

  58. “Testing and Analysis of 4 by 2 Parallel-Chord Metal-Plate-Connected Trusses,”Research Report 81-1, Small Homes Council-Building Research Council, University of Illinois at Urbana-Champaign, 1981.

  59. Quality Control Inspection Program, Truss Plate Institute, Madison, Wisc., January 1, 1987.

  60. “Lumber Moisture Content Effect on Plated Truss Design,”Technical Report No. 1, Truss Plate Institute, Madison, Wisc., May 1984.

  61. The Alpine Floor Truss System, Alpine Truss Engineered Systems, 1972.

  62. Mittendorf, John W., and Brannigan, Francis L., “The Timber Truss: Two Points of View,”Fire Engineering, May 1991.

  63. Manny, William F., “Lightweight Wood Trusses: More to Consider,”Fire Engineering, May 1991.

  64. Routley, J. Gordon, “How Wood Trusses Perform During a Real Fire,”Fire Journal, January/February 1989.

  65. Construction for Fire Protection: A Guide to Wood/Plywood Systems that Meet Code and Insurance Requirements, American Plywood Association, Tacoma, Wash.

  66. Fire Resistance Ratings, American Insurance Services Group, 1990.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Malanga, R. Fire endurance of lightweight wood trusses in building construction. Fire Technol 31, 44–61 (1995). https://doi.org/10.1007/BF01305267

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01305267

Key words

Navigation