Skip to main content
Log in

Blood pH Measurement with a Solvent Polymeric Membrane Electrode in Comparison with a Glass Electrode

Vergleichsmessungen von pH-Werten in Blut mittels einer Flüssigmembranelektrode und einer Glaselektrode

  • Published:
Microchimica Acta Aims and scope Submit manuscript

Summary

A neutral carrier based solvent polymeric membrane electrode selective for hydrogen ions leads to standard deviations for single measurements of the pH in blood samples and related buffers of 0.001 to 0.003 pH units. The pH values obtained by this electrode on 35 blood samples correlate with those measured with a glass electrode with a correlation coefficient of 0.998 and a residual standard deviation of 0.01 pH units.

Zusammenfassung

Messungen von pH-Werten mit einer auf einem elektrisch neutralen Carrier beruhenden, H+-selektiven Flüssigmembranelektrode in Blutproben und Eichpufferlösungen ergeben Standardabweichungen für einzelne Messungen von 0,001 bis 0,003 pH-Einheiten. Eine Korrelation der mit dieser Elektrode an 35 Blutproben ermittelten pH-Werte mit den Meßwerten einer Glaselektrode ergibt einen Korrelationskoeffizienten von 0,998 und eine Restabweichung von 0,01 pH-Einheiten.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. O. H. Le Blanc, Jr., J. F. Brown, Jr., J. F. Klebe, L. W. Niedrach, G. M. J. Slusarczuk, and W. H. Stoddard, Jr., J. Appl. Physiol.40, 644 (1976).

    Google Scholar 

  2. D. Erne, D. Ammann, and W. Simon, Chimia33, 88 (1979).

    Google Scholar 

  3. D. Erne, K. V. Schenker, D. Ammann, E. Pretsch, and W. Simon, Chimia35, 178 (1981).

    Google Scholar 

  4. P. Schulthess, Y. Shijo, H. V. Pham, E. Pretsch, D. Ammann, and W. Simon, Analyt. Chim. Acta131, 111 (1981).

    Google Scholar 

  5. H.-B. Jenny, D. Ammann, R. Dörig, B. Magyar, R. Asper, and W. Simon, Mikrochim. Acta [Wien]1978 II, 235.

    Google Scholar 

  6. R. G. Bates, J. Research NBS66 A, 179 (1962).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Anker, P., Ammann, D. & Simon, W. Blood pH Measurement with a Solvent Polymeric Membrane Electrode in Comparison with a Glass Electrode. Mikrochim Acta 79, 237–242 (1983). https://doi.org/10.1007/BF01303909

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01303909

Keywords

Navigation