Conclusions

Tests of experimental-industrial electric filters PGDS, fitted behind rotary kilns Nos. 7 and 8 for burning magnesite at the Magnezit Factory showed that with a gas velocity in the filter of 1.4 m/sec, and heating the kiln with natural gas, the efficiency of the equipment is 94.4%. The relatively low efficiency of the filter is due to the high electrical resistance of the magnesite dust, and as a result of this the operation of the equipment in a back corona cycle.

To speed up the operation of the electric filter we recommend conditioning of the dust—gas current.

Heating rotary kilns with high-sulfur oil, the effectiveness of the filter with a gas velocity of 1.2 m/sec after 25 days of continuous operation dropped from 91.8 to 57.7%. The main cause of the unsatisfactory operation of the filter is the overgrowth of the electrodes with a layer of dust (of the Sorel cement type) which is difficult to remove.

Thus, using oil, the electric filters of the Magnezit Factory cannot guarantee effective dust removal.

In order to increase the efficiency of the filters it is necessary to make a study of the effectiveness of additives to the oil (liquid additives) developed by Soviet industry.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature cited

  1. G. M. A. Aliev et al., Ogneupory, No. 9, 11 (1967).

    Google Scholar 

  2. G. M. A. Aliev and I. D. Minaev, Ogneupory, No. 3, 15 (1971).

    Google Scholar 

  3. G. M. A. Aliev and A. E. Gonik, Instrument for Measuring the Resistivity of Dusts with Cyclone-1 [in Russian], GOSINTI (1968), p.1.

  4. G. M. A. Aliev et al., Ogneupory, No. 1, 8 (1969).

    Google Scholar 

  5. B. S. Belosel'skii and V. N. Pokrovskii, Sulfur Oil in Power Engineering [in Russian], Energiya (1969), p. 112.

  6. Use of Liquid Additives to Oil Used in Boilers [in Russian], TsKTI Leningrad (1968), p. 7.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Ogneupory, No. 11, pp. 48–51, November, 1972.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aliev, G.M.A., Sarafanov, V.F. Efficiency of electric filters for removing magnesite dust. Refractories 13, 736–739 (1972). https://doi.org/10.1007/BF01284119

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01284119

Keywords

Navigation