Abstract
Fifty-six patients in Europe were entered into a multi-centre study to compare the accuracy of technetium 99m methoxyisobutylisonitrile (99mTc-MIBI) for the detection of coronary artery disease (CAD) with thallium 201 (201T1) chloride perfusion scanning. The results showed a high degree of concordance between the two radiopharmaceuticals. Some 81% (678/840) of myocardial segments showed the same result (normal, infarct or ischaemia), and 80% (45/56) of patients had the same diagnosis. Overall detection of CAD in patients was 98% for201T1 and 96% for99mTc-MIBI. Detection of CAD in total arteries was 68% for both agents. In this study99mTc-MIBI was as accurate as201T1 for the detection of coronary artery stenoses.
References
Buell U, Kaiser HJ, DuPont F, Uebis R, Kleinhans E, Hanrath P (1990) Methoxyisobutylisonitrile (MIBI) Tc 99m SPELT to establish a correlate to coronary flow reserve, the perfusion reserve, from global and regional myocardial uptake after exercise and rest. Eur J Nucl Med 16:3–9
Clausen M, Henze E, Schmidt A, Weller R, Lietzenmeyer R, Hellwig D, Bitter F, Hildebrand P, Hombach V, Adam WE (1989) The contraction fraction (CF) in myocardial studies with technetium-99m-isonitrile (MIBI) — correlations with radionuclide ventriculography and infarct size measured by SPELT. Eur J Nucl Med 15:661–664
Kahn JK, McGhie I, Akers MS, Sills MN, Faber TL, Kulkarni PV, Willerson JT, Corbett JR (1989) Quantitative rotational tomography with 201T1 and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease. Circulation 79:1282–1293
Kiat H, Maddahi J, Roy LT, Van-Train K, Friedman J, Resser K, Berman DS (1989) Comparison of technetium 99m methoxyisobutyl isonitrile and thallium-201 for evaluation of coronary artery heart disease by planar and tomographic methods. Am Heart J 117:1–11
Majeed Q, Najm YC, Maisey MN (1989) Improving diagnostic quality with end diastolic 99m-Tc hexakis 2-methoxyisobutyl isonitrile images. Nucl Med Commun 10:210–211 (Abstract)
Najm YC, Timmis AD, Maisey MN, Ellam SV, Mistry R, Curry PVL (1989) The evaluation of left ventricular function using gated myocardial imaging with Tc-99m MIBI. Eur Heart J10:142–148
Sinusas AJ, Beller GA, Smith WH, Vinson EL, Brookeman V, Watson DD (1989) Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201, J Nucl Med 30:1456–1463
Taillefer R, Lambert R, Dupras G, Gregoire J, Leveille J, Essiambre R, Phaneuf D-C (1989a) Clinical comparison between thallium-201 and Tc-99m methoxyisobutylisonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease. Eur J Nucl Med 15:280–286
Taillefer R, Gagnon A, Laflamme L, Gregoire J, Leveille J, Phaneuf D-C (1989b) Same day injections of Tc-99m methoxy isobutyl isonitrile (hexamibi) for myocardial tomographic imaging: comparison between rest-stress and stress-rest injection sequences. Eur J Nucl Med 15:113–117
Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R, Inglese E, Delaloye B, Bischof-Delaloye A, Camin L, McKusick K (1989) Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 30:301–311
West DJ, Najm YC, Mistry R, Clarke SEM, Fogelman I, Maisey MN (1989) The localization of myocardial ischaemia with technetium-99m methoxyisobutyl isonitrile and single photon emission computed tomography. Br J Radiol 62:303–313
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Maisey, M.N., Lowry, A., Bischof-Delaloye, A. et al. European multi-centre comparison of thallium 201 and technetium 99m methoxyisobutylisonitrile in ischaemic heart disease. Eur J Nucl Med 16, 869–872 (1990). https://doi.org/10.1007/BF01280254
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01280254