Skip to main content
Log in

Linear scan stripping voltammetry of copper(II) at the chemically modified carbon paste electrode

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

A new chemically modified electrode (CME), α-benzoinoxime (CUPRON) modified carbon paste electrode, for determining copper(II) is reported because of its excellent selectivity and sensitivity. The electrode is made by mixing a quantity of CUPRON (25%, w/w) with graphite powder (50%, w/w) and paraffin oil (25%, w/w). The CME preferentially deposits copper from the pH 8.5 NH3-NH4Cl buffer solution containing copper(II) under an open circuit and most of metal ions do not interfere with the measurements. The detection limit (S/N of three) for determining Cu(II) is 3 × 10−10 g/ml after 10 min accumulation in fast linear scan stripping voltammetric measurement. Linear calibration curves are obtained for Cu(II) concentration ranged from 1 × 10−8 M to 1 × 10−6 M. The response can be maintained with relative standard deviation of 6.0% in a 5 × 10−6 M Cu(II) solution after eight accumulation/measurement/ regeneration cycles at the same electrode surface. The effect resulted from carbon paste preparation, reduction potential, electrode renewal, electrolyte and solution pH, preconcentration time, concentration dependence, possible interference and other variables has been evaluated. As for application, the CME demonstrates its high sensitivity and copper-selectivity in complex composition samples, such as anodic mud and polluted water.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. P. Baldwin, J. K. Christensen, L. Kruger,Anal. Chem. 1986,58, 1790.

    Google Scholar 

  2. K. H. Lubert, M. Schnurrbusch,Anal. Chim. Acta 1986,186, 57.

    Google Scholar 

  3. S. V. Prabhu, R. P. Baldwin, L. Kryger,Electroanalysis 1989,1, 13.

    Google Scholar 

  4. J. Wang, T. Peng, R. Li, J. Zadeii,Anal. Lett. 1989,22, 719.

    Google Scholar 

  5. J. Wang, T. Martinez,Electroanalysis 1989,1, 167.

    Google Scholar 

  6. J. Wang, T. Martinez,Anal. Chim. Acta 1988,207, 95.

    Google Scholar 

  7. J. Wang, M. Bonakdar,Talanta 1988,35, 277.

    Google Scholar 

  8. K. Kalcher,Anal. Chim. Acta 1985,777, 175.

    Google Scholar 

  9. A. Amine, J. M. Kauffmann, G. G. Guilbault, S. Bacha,Anal. Lett. 1993,26, 1281.

    Google Scholar 

  10. T. Peng, H. Li, S. Wang,Analyst 1993,118, 1321.

    Google Scholar 

  11. S. Zhang, F. Tang, T. Zhang,The Handbook of Modern Chemical Reagents, Chem. Indus. Press, Beijing, 1989, p. 540.

    Google Scholar 

  12. T. Peng, Z. Yang, R. Lu,Talanta 1991,38, 741.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Peng, T., Sheh, L. & Wang, G. Linear scan stripping voltammetry of copper(II) at the chemically modified carbon paste electrode. Mikrochim Acta 122, 125–132 (1996). https://doi.org/10.1007/BF01252414

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01252414

Key words

Navigation