Skip to main content
Log in

Matrix modification by Cu(NO3)2 for the determination of gold by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

Matrix modification by copper nitrate in electrothermal atomic absorption Spectrometry (ETAAS) of gold with a molybdenum tube atomizer has been investigated. The addition of copper nitrate served to eliminate the interferences from 104–105-fold concentrations of foreign elements at the 890 °C pyrolysis temperature. The absolute characteristic mass (giving 0.0044 absorbance) of gold in the presence of copper nitrate with the Mo atomizer was 0.26 pg and the detection limit was 38 pg/ml. These values were several times better than those obtained with graphite atomizers. The recovery of spiked gold in biological materials was in the range 96–106%. A sensitive and accurate ETAAS method was developed for complex matrix samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. Lang, O. Wawschinek, F. Rainer, G. Lanzer,Mikrochim. Acta 1983,III, 53.

    Google Scholar 

  2. J. Egila, D. Littlejohn, J. M. Ottaway, X. Shan,J. Anal. At. Spectrom. 1987,2, 293.

    Google Scholar 

  3. X. Shan, J. Egila, D. Littlejohn, J. M. Ottaway,J. Anal. At. Spectrom. 1987,2, 299.

    Google Scholar 

  4. L. Thunus, J. F. Dauphin,Anal. Chim. Acta 1990,235, 393.

    Google Scholar 

  5. M. Suzuki, K. Ohta,Prog. Anal. At. Spectrosc. 1983,6B, 49.

    Google Scholar 

  6. K. Ohta, T. Ishiyama, M. Yokoyama, T. Mizuno,Talanta 1995,42, 263.

    Google Scholar 

  7. D. O. Matthews, M. C. McGaham,Spectrochim. Acta 1987,42B, 909.

    Google Scholar 

  8. L. H. J. Lajunen,Spectrochemical Analysis by Atomic Absorption and Emission, Royal Society of Chemistry, Cambridge, 1992, pp. 97, 99–100, 186–189, 230.

    Google Scholar 

  9. P. Chattopadhyay, B. N. Sahoo,Analyst 1992,117, 1481.

    Google Scholar 

  10. S. Hara, H. Matsuo, T. Kumamaru,Bunseki Kagaku 1986,35, 503.

    Google Scholar 

  11. M. Aihara, H. Watanabe, M. Kiboku,Anal. Sci. 1991 [Suppl. 7], 87.

    Google Scholar 

  12. C. Garcia-Olalla, A. J. Aller,Anal. Chim. Acta 1991,252, 97.

    Google Scholar 

  13. A. J. Aller,Anal Chim. Acta 1994,292, 317.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ohta, K., Yokoyama, M., Ogawa, J. et al. Matrix modification by Cu(NO3)2 for the determination of gold by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer. Mikrochim Acta 122, 61–66 (1996). https://doi.org/10.1007/BF01252406

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01252406

Key words

Navigation