Summary
A model is developed that allows the prediction of the film cooling effectiveness produced by slot injection into a uniform cross flow. The model relies on the fact that when the slot pressure exceeds the cross flow pressure by a small amount only so that injection is weak, the resulting small parameter may be exploited to solve the flow problem. The energy equation for the flow may then be solved to determine how much protection cold gas injection gives to the wall downstream of a slot. Although the leading order energy equation must be solved numerically, a simple asymptotic expression may also be derived to allow predictions of heat transfer at large distances from the injection slot.
Similar content being viewed by others
References
Barry, B.: The aerodynamic penalties associated with blade cooling. In: Turbine blade cooling. Von Kármán Institute. VKI LS 83 1976.
Fitt, A. D., Ockendon, J. R., Jones, T. V.: Aerodynamics of slot — film cooling: theory and experiment. J. Fluid Mech.160, 15–27 (1985).
Goldstein, R. J.: Film cooling. Adv. Heat Transfer7, 321–379 (1971).
Dewynne, J. N., Howison, S. D., Ockendon, J. R., Morland, L. C., Watson, E. J.: Slot suction from inviscid channel flow. J. Fluid Mech.200, 265–282 (1989).
Van Dyke, M.: Perturbation methods in fluid dynamics. New York: Academic Press 1964.
Fitt, A. D., Wilmott, P.: Slot film cooling — the effect of separation angle. Acta Mech.103, 79–88 (1994).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fitt, A.D., Stefanidis, V. Film cooling effectiveness for subsonic slot injection into a cross flow. Acta Mechanica 128, 233–242 (1998). https://doi.org/10.1007/BF01251893
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01251893