Cobalt-57 flood sources are often used for system flood-field uniformity checks of scintillation camera performance. Such sources are now available in large sizes and with high activities. Uniformity images using new57Co sources have shown artefacts which are not present in uniformity images obtained from technetium-99m flood sources of the same activity. The high-energy photons emitted by57Co and cobalt isotope impurities appear to influence the images obtained. This was investigated in three cameras using three57Co sources of different age. The flood-field images obtained with the57Co sources showed non-uniformity patterns that were dependent on the age of the cobalt source, the distance of the source to the collimator, and the specific camera type. Quantification of the uniformity images reflected these findings. Energy spectra of a new57CO source, obtained with an external 1024-channel analyser connected to the camera., showed a broad tail of high-energy photons above the 122-keV photopeak, due to Compton scatter and collimator penetration. This tail diminished with older sources and with increased source to collimator distance, indicating that in both situations fewer high-energy photons were being measured by the camera system. This tail of high-energy photons contributes to the total count rate, but because this is not obvious from the counts observed in the photopeak window, the camera can unsuspectingly be operated at too high a total countrate where pile-up effects become significant. Caution is therefore advised when using57Co sources. Problems may be minimized by purchasing low-activity sources (certainly no more than 370 MBq), by placing the source at a distance from the collimator, e.g. 50 cm, by allowing a new source to decay, and by manufacturers producing57Co sources without detectable radioactive contaminants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. IEC Publication 789.Characteristics and test conditions for Anger-type gamma cameras. Geneva: International Electrical Commission, 1992.

  2. DIN 6855, Teil 2.Qualitätsprüfung nuklearmedizinischer Meßsysteme. Meßbedingungen für die Einzelphotonen-Emissions-Computertomographie mit Hilfe rotierender Meß-köpfe einer Gamma-Kamera. Berlin: Deutsches Institut für Normung e.V, 1993.

  3. IAEA-TECDOC-602.Quality control of nuclear medicine instruments 1991. Vienna: International Atomic Energy Agency; 1991.

  4. IPSM Report No. 66.Quality control of gamma cameras and associated computer systems. York: The Institute of Physical Sciences in Medicine, 1992.

  5. Cranage, RW, Peake JFC. The effect of high-energy-impurities on measurements of gamma-camera resolution and uniformity using57Co flood sources.Br J Radiol 1979; 52: 81–82.

    Google Scholar 

  6. Busemann Sokole, E. Non-uniformity effects from cobalt-57 flood sources.Eur J Nucl Med 1991; 18: 530.

    Google Scholar 

  7. Table of isotopes, 7th edn. Lederer CM, Shirley VS, eds. New York: Wiley; 1978: 162–177.

    Google Scholar 

  8. NEMA Standards Publication NU-1-1986.Performance measurements of scintillation cameras. Washington DC: National Electrical Manufacturers Association, 1986.

  9. Guldberg C, Rossing N. Comparing the performance of two gamma cameras under high counting rates: principles and practice. J Nucl Med 1978; 19: 545–552.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sokole, E.B., Heckenberg, A. & Bergmann, H. Influence of high-energy photons from cobalt-57 flood sources on scintillation camera uniformity images. Eur J Nucl Med 23, 437–442 (1996). https://doi.org/10.1007/BF01247373

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01247373

Key words

Navigation