Contents
Partial discharges take place, among others, inside voids enclosed in insulations. The partial discharge behaviour of epoxy resin samples is studied with the aid of a recently developed streamer partial discharge model (Pedersen's model) and its relation to the modem Pulse Height Analysis and Phase Resolved Measurement techniques is investigated. Furthermore, some relations based on Pedersen's model are deduced. The advantages and disadvantages of the aforementioned model are analysed. Scanning electron microscope photographs show the nature of the deterioration of the void walls due to the partial discharges. The question whether initiation of the treeing phenomenon leading to breakdown from an enclosed spherical void is possible, is also investigated.
Übersicht
Teilentladungen verursachen eine Alterung der Isolierstoffsysteme. Sie können in Hohlräumen der Isolierstoffe stattfinden. Das Teilentladungsverhalten von Hohlräumen in Epoxydharz wird mit der Hilfe von Pulse Height und Phase Resolve Analysis studiert und mit der Hilfe des Pedersen-Modells analysiert. Einige mathematische Verhältnisse diese Modells werden vorgeschlagen. Die Vorteile und Grenzen dieses Modells werden analysiert. Rastermikroskop-Aufnahmen zeigen die Art der Schädigung der Hohlraumwände. Frage, ob das Phänomen der Bäumchen von einem Hohlraum zu einem Durchschlag der Isolation führen kann, wird nachgegangen.
Similar content being viewed by others
References
Gallagher, T. J.;Pearmain, A. J.: (1983) High Voltage Measurement, Testing and Design. John Wiley and Sons, New York
Kind, D.;Kärner, H.: (1982) Hochspannungsisoliertechnik. Vieweg, Braunschweig
König, D.; Quint, I.: (1992) Multifactor aging mechanisms on the surface of model post insulators. Conf. El. Insul. Diel. Phen. 664–671
König, D.: (1994) Surface and ageing phenomena on organic insulation under the condition of light contamination and high electric stress. Proc. Nord. Insul. Symp. Paper 0.1
Mole, G.: (1953) Improved methods of test for the insulation of electrical equipment. Proc. IEE 100:276–283
Mason, J. H.: (1951) The Deterioration and breakdown of dielectrics resulting from internal discharges. Proc. IEE 98:44–59
Kelen, A.: (1967) Studies on partial discharges on solid dielectrics — A contribution to the discharge resistance testing of insulating materials. Acta Polyt. Scand. 16:138
Devins, J. C.. (1984) The Physics of Partial Discharges in Solid Dielectrics. IEEE Trans. Elec. Insul. 19:475–495
Bartnikas, R.: (1990) Detection of Partial Discharges (Corona) in Electrical Apparatus. IEEE Trans. Elec. Insul. 25:111–124
Gemant, A.: (1932) Die Verlustkurve lufthaltiger Isolierstoffe. Z. Techn. Phys. 13:184–189
Gemant, A.;Philippoff, W. V.: (1932) Die Funkenstrecke mit Vorkondensator. Z. Techn. Phys. 13:425–430
Crichton, G. C.;Karlsson, P. W.;Pedersen, A.: (1989) Partial discharges in ellipsoidal and spheroidal voids. IEEE Trans. Elec. Insul. 24:335–342
Pedersen, A. (1987) Partial discharges in voids in solid dielectrics — An alternative approach Conf. Elec. Insul. Diel. Phen. 58–64
Garcia, G.; Fallou, B.: (1983) Equipment for the energy measurement of partial discharges. Proc. Ist Int. Conf. Cond. Breakdown Solid Diel. 275–281
Pearmain, A. J.;Danikas, M. G.: (1987) A study of the behavior of a uniaxially oriented polyethylene tape/oil insulating system subjected to electrical and thermal stresses. IEEE Trans. Elec. Insul. 22:373–382
Kelen, A.;Danikas, M. G.: (1995) Evidence and presumption in PD diagnostics. IEEE Trans Diel. Elec. Insul. 2:780–795
Gulski, E.: (1991) Computer-aided recognition of PD using statistical tools. PhD Thesis, Delft University of Technology
GKrivda, A.: (1995) Recognition of discharges — Discrimination and classification. PhD Thesis, Delft University of Technology
Fruth, B.; Liptak, G.; Ullrich, L.; Dunz, T.; Niemeyer, L.: (1989) Ageing of rotating machines insulation — Mechanisms, measurement techniques. Proc. 3rd Int. Conf. Cond. Breakdown Solid Diel. 597–601
Danikas, M. G.: (1991) Discharges in polymers. Proc. 3rd JICABLE. 267–271
Danikas, M. G.; Bruning, A. M.: (1992) Comparison of several sub-corona to corona transition relations with recent experimental results. IEEE Int. Symp. Elec. Insul. 383–388
Kim, Y. J., Nelson, J. K.: (1992) Assessment of diterioration in epoxy/mica machine insulation. IEEE Trans. Elec. Insul. 27:1026–1039
Ryder, D. M.: (1993) The interpretation of partial electrical discharge measurements with insulation damage and ageing. Conf. Elec. Insul. Diel. Phen. 642–647
Ryder, D. M.;Wood, J. W.;Hogg, W. K.: (1975) The deterioration of mica under the action of electrical discharges. IEEE Trans. Power App. Sys. 94:1013–1020
Starr, W. T.: (1979) Detection of corona discharges in lamped circuit specimens. ASTM Special Techn. Publ. 669:101–133
Reynolds, S. I.. (1959) On the Behaviour of natural and artificial voids in insulation under internal discharge. IEEE Trans. Power App. Sys. 77:1604–1608
Bruning, A. M.;Kasture, D. G.;Campbell, F. J.;Turner, N. H.: (1991) Effect of cavity sub-corona on polymer insulation life. IEEE Trans. Elec. Insul. 26:826–836
Turner, N. H.;Bruning, A. M.: (1995) Analysis of electrical in sulator surfaces by X-ray photoelectron spectroscopy. IEEE Trans. Diel. Elec. Insul. 2:1140–1146
Danikas, M. G.;Bartnikas, R.;Novak, J. P.: (1993) On the spark to pseudoglow and glow transition mechanism and discharge detectability. IEEE Trans. Elec. Insul. 28:429–431
McAllister, I. W.: (1991) Electric field theory and the fallacy of void capacitance. IEEE Trans. Elec. Insul. 26:458–459
Sletbak, J.: (1992) Partial discharge measurements-Possibilities and limitations. Proc. 4th Int. Conf. Cond. Breakdown Solid Diel. 145–149
Gjaerde, A. C.: (1994) Multi factor ageing of epoxy—The combined effect of temperature and partial discharges. PhD Thesis, Norwegian Institute of Technology
König, D.;Rao, Y. N.: (1993) Teilentladungen in Betriebsmitteln der Energietechnik. VDE-Verlag, Berlin
Tanaka, T.: (1986) Internal partial discharge and material degradation. IEEE Trans. Elec. 21:899–905
Morshuis, P. H. F.: (1993) Partial discharge mechanisms—Mechanisms leading to breakdown analyzed by fast electrical and optical measurements. PhD Thesis, Delft University of Technology
Author information
Authors and Affiliations
Additional information
The experimental results were obtained at ABB, Baden/Switzerland. One of the authors is indebted to Dr. L. Niemeyer and Dr. B. Fruth for fruiful discussions.
Rights and permissions
About this article
Cite this article
Danikas, M.G., Adamidis, G. Partial discharges in epoxy resin voids and the interpretational possibilities and limitations of Pedersen's model. Electrical Engineering 80, 105–110 (1997). https://doi.org/10.1007/BF01245959
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01245959