Abstract
Recent research work is reported on cold cathode luminescence (CL) microscopy and CL microspectrophotometry of diamond produced by means of plasma-activated mixtures of hydrogen and methane gases. Diamond layers of octahedral, cubooctahedral or cubic habit on SiAlON substrates as well as ballas-type layers were investigated. Diamond was also deposited on sheet substrates of titanium, niobium, tantalum, chromium, molybdenum, tungsten, iron (spheroidal and lamellar cast iron), cobalt and nickel. Studying CL colors together with CL spectra has proved to be a reliable diagnostic method for differentiating between the morphological properties of CVD diamond on SiAlON substrates. It is however not possible with this method to clearly differentiate all diamond layers on any one of the sample substrates investigated. These findings could justify a future application of both CL microscopy and CL microspectrophotometry in production control.
Similar content being viewed by others
References
P. K. Bachmann, D. Leers, H. Lydtin,Diamond Relat. Mater. 1991,1, 1.
B. Lux, R. Haubner,J. Ref. Hard Metals,1989,8, 158.
B. Lux, R. Haubner,Diamond and Diamond-Like Films and Coatings, NATO-ASI, Series B: Physics, Vol. 266 (R. E. Clausing et al., eds.), Plenum, New York, 1991, pp. 579–609.
J. A. Savage,J. Crystal Growth 1991,13, 698.
K. E. Spear,J. Am. Ceram. Soc. 1989,72, 171.
B. Lux, R. Haubner, P. Renard,Diamond Relat. Mater. 1992,1, 1035.
H. Itoh, T. Nakamura, H. Iwahara, H. Sakamoto,J. Crystal Growth 1991,108, 647.
D. J. Pickrell, W. Zhu, A. R. Badzian, R. E. Newnham, R. Messier,J. Mater. Res. 1991,6, 1264.
R. Ramesham, T. Roppel, B. F. Hajek, C. Ellis,J. Electrochem. Soc. 1990,137, 3203.
R. Ramesham, T. Roppel, C. Ellis, D. A. Jaworske, W. Baugh,J. Mater. Res. 1991,6, 1278.
A. T. Collins, M. Kamo, Y. Sato,J. Phys. D, Appl. Phys. 1989,22, 1402.
A. T. Collins, M. Kamo, Y. Sato,J. Phys. Condens. Matter 1989,1, 4029.
W. J. P. van Enckevort, G. Janssen, W. Vollenberg, M. Chermin, L. J. Giling, M. Seal,Surf. Coat. Technol. 1991,47, 39.
H. Kawarada, K. Nishimura, T. Ito, J.-I. Suzuki, K-Sh. Mar, Y. Yokota, A. Hiraki,Jap. J. Appl. Phys. 1988,27, L683.
H. Kawarada, Y. Yokota, Y. Mori, K. Nishimura, A. Hiraki,J. Appl. Phys. 1990,67, 983.
L. H. Robins, L. P. Cook, E. N. Farabaugh, A. Feldman,Phys. Rev. B 1989,39, 13367.
A. Lindlbauer: Doctoral Thesis, TU-Vienna, 1992
A. Lindlbauer, R. Haubner, B. LuxRM&HM,1992,11, 247.
J. Ponahlo,Z. Dt. Gemmol. Ges. 1989,38, 63.
J. Ponahlo,J. Gemmol. 1992,23, 3.
R. Haubner, A. Lindlbauer, B. Lux,Diamond Relat. Mater. 1993,2, 1505.
A. Lindlbauer, R. Haubner, B. Lux,Diamond Films Technol.,1992,2, 81.
N. Yamamoto, J. C. H. Spence, D. Fathy,Phil. Mag. 1984,B49, 609.
J. Walker,Rep. Prag. Phys. 1979,42, 1605.
V. S. Vavilov, A. A. Gippius, B. V. Zaitsev, B. V. Deryagin, B. V. Spitsyn, A. E. Aleksenko,Sov. Phys. Semicond. 1980,14, 1078.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ponahlo, J., Haubner, R. & Lux, B. Cathodoluminescence (CL) and CL spectra of microwave plasma-enhanced CVD diamond. Mikrochim Acta 116, 143–156 (1994). https://doi.org/10.1007/BF01244072
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01244072