A comparison of X-ray fluorescence spectrometric (XRF) techniques for the determination of metal traces, especially in plastics

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

A comparative study of energy-dispersive X-ray fluorescence techniques (without and with polarized radiation) and a wavelength-dispersive technique was carried out in order to investigate their sensitivity for the quantitative determination of 3d transition metal traces in plastic materials. For this purpose, liquid calibration samples in paraffin oil for the elements Cr, Mn, Co, Ni and Cu were prepared. Calibration lines in the concentration range of 1–100 μg/g were evaluated for commercially available XRF-instruments and the results were critically compared. Limits of detection (LOD) ranged from 0.1 to 0.7 μg/g for wavelength-dispersive XRF and energy-dispersive XRF with polarized radiation. The LOD's for energy-dispersive XRF without polarized radiation ranged from 0.9 to 8.6 μg/g for elements in the same atomic number range between 24 and 29. The application of these optimized methods to the quantitation of wear and corrosion phenomena in plastic extruders and in a relevant model test apparatus, the annular slit tribometer, is elucidated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. Mennig (ed.),Wear in the Processing of Plastics, Hanser, München, 1990, p. 8 (in German).

    Google Scholar 

  2. G. Paller,Kunststoffe 1991,81, 626.

    Google Scholar 

  3. P. Hoffmann, G. Paller, B. Thybusch, U. Stingl,Fresenius J. Anal. Chem. 1991,339, 230.

    Google Scholar 

  4. G. L. Long, J. D. Winefordner,Anal. Chem. 1983,55, 712 A.

    Google Scholar 

  5. M. Brumme,Thesis, Department of Physics, University of Technology, Dresden, 1990.

    Google Scholar 

  6. J. Heckel, M. Haschke, M. Brumme, R. Schindler,J. Anal. At. Spectr. 1992,7, 281.

    Google Scholar 

  7. R. Spatz, K. H. Lieser,Fresenius Z. Anal. Chem. 1976,280, 197.

    Google Scholar 

  8. R. Spatz, K. H. Lieser,Fresenius Z. Anal. Chem. 1978,293, 25.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Metz, U., Hoffmann, P., Weinbruch, S. et al. A comparison of X-ray fluorescence spectrometric (XRF) techniques for the determination of metal traces, especially in plastics. Mikrochim Acta 117, 95–108 (1994). https://doi.org/10.1007/BF01243020

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01243020

Key words

Navigation