Abstract
The Bicarbon prosthetic heart valve with two curved leaflets is designed so that the blood flows through the three orifices are parallel jets of equal size. This study was conducted to confirm that the Bicarbon valve functions clinically as designed. Forty-three patients underwent valve replacement with the Bicarbon valve. Forty-eight Bicarbon valves were implanted: 25 valves in the mitral position and 23 in the aortic position. Peak blood flow velocity through the three prosthetic orifices was measured postoperatively by Doppler echocardiography. The three flow jets through the prosthesis were parallel. The velocity through the lateral orifice was 2.33±0.38 m/min, and the velocity through the central orifice was 2.14±0.43 m/min at the aortic position (P>0.05). The velocity through the lateral orifice was 1.72±0.06 m/min at the mitral position, and that through the central orifice was 1.73±0.06 m/min (P>0.05). Serum lactic acid dehydrogenase values were also lower than those of patients or whom another bileaflet prosthesis had been implanted. The results confirm that the Bicarbon prosthetic heart valve performs clinically as designed, producing three parallel blood flow jets with equal flow velocity.
Similar content being viewed by others
References
Vallana F, Rinaldi S, Galletti PM, Nguyen A, Piwnica A. Pivot design in bileaflet valves. ASAIO 1992;38:M600–606
Edmunds LH, Clark RE, Cohn LH, Grunkemeier GL, Miller DC, Weisel RD. Guideline for reporting morbidity and mortality after cardiac valvular operations. Ann Thorac Surg 1996;62:932–935
Misawa Y, Hasegawa H, Kato K. Clinical experience with the Omnicarbon prosthetic heart valve. Thorac Cardiovasc Surg 1993;105:168–172
Thevenet A, Albat B. Long term follow up of 292 patients after valve replacement with the Ominicarbon prosthetic valve. J Heart Valve Dis 1995;4:634–639
Kratz JM, Crawford FA, Sade RM, Crumbley AJ, Stoud MR. St. Jude prosthesis for aortic and mitral valve replacement: a ten-year experience. Ann Thorac Surg 1993;56:462–468
Podesser BK, Khuenl-Brady G, Eigenbauer E, Roedler S, Schmiedberger A, Wolner E, Morittz A. Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: a prospective ten-year clinical follow-up. J Thorac Cardiovac Surg 1998;115:1211–1129
Okita Y, Kusuhara K, Ueda Y, Tahata T, Tsukamoto Y, Yamanaka K, Shiraishi S. Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St. Jude Medical prosthesis. Ann Thorac Surg 1998;46:89–92
Misawa Y, Konishi H, Fuse K, Hasegawa T, Kato M, Hasegawa N, Kawahito K. Mid term clinical results with the Carbo Medics prosthetic heart valve. Jpn J Cardiovasc Surg 1997;25(suppl):113
Casselman F, Herijigers P, Meyns B, Flameng W, Daenen W. The Bicarbon heart valve prosthesis: short-term results. J Heart Valve Dis 1997;6:410–415
Di Salvo C, Walesby RK. Early single centre experience with 192 Sorin Bicarbon valves. J Cardiovasc Surg 1996;37:13–15
Kuwaki K, Abe T, Komatsu K, Koshima R, Komatsu S. Early clinical results of Bicarbon valve prosthesis. Jpn J Artif Organs 1996;25:596–598 (in Japanese with English abstract)
Badano L, Mocchegiani R, Bertoli D, DeGaetano G, Carratino L, Pasetti L, Caudullo M, Budini A, Mannello B, Passerone G. Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions. J Am Soc Echocardiogr 1997;10:632–643
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Misawa, Y., Fuse, K., Kamisawa, O. et al. Echocardiographic characteristics of transprosthetic blood peak velocity in the Sorin Bicarbon bileaflet prosthetic heart valve. J Artif Organs 2, 74–77 (1999). https://doi.org/10.1007/BF01235528
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01235528