Skip to main content
Log in

Photometric measurement of color changes in livor mortis as a function of pressure and time

Development of a computer-aided system for measuring pressure-induced blanching of livor mortis to estimate time of death

  • Original Articles
  • Published:
International Journal of Legal Medicine Aims and scope Submit manuscript

Summary

Until now, blanching of livor mortis in estimating time of death has generally been assessed based on subjective impressions, i.e. on whether blanching is visible after the application of pressure. We have developed a measuring system that uses digital processing to objectify the relationship between the pressure applied and blanching of postmortem lividity. The pressure is electronically registered by a strain gauge. At predefined levels (10, 20, 30, up to 100N) the software triggers a color measurement by a commerically available tristimulus colorimeter. All parameters are measured in a single procedure and routed to the computer through a data interface. The pressure-induced color changes in the livor mortis are evaluated according to the L*, a*, b* system (CIE-LAB according to DIN 5033, DIN 6174), which closely approximates the physiology of sight. An additional color spacing formula (AE) allows analysis of color changes irrespective of the basic skin tone. Initial measurements on cadavers showed that application of increasing pressure produced regular courses of color changes in livor mortis.

Zusammenfassung

Bislang wurde die „Wegdrückbarkeit” der Totenflecken bei der Todeszeitschätzung im wesentlichen nach subjektiven Eindrücken beurteilt-danach, ob die Totenflecke leicht, vollständig, schwer und/oder unvollständig wegdrückbar sind. Ein neues Meßsystem objektiviert die Beziehungen zwischen Kraftaufwand und Farbänderung der livores („Wegdrückbarkeit”) durch digitale Verarbeitung von Meßgrößen. Der Kraftaufwand während des Drucks auf den Totenfleck wird mittels Dehnungsmeßstreifen elektronisch erfaßt. Bei Erreichen definierter Druckstärken (10, 20, 30 bis 100 Newton) löst ein Computerprogramm jeweils eine Farbmessung mit einem handelsüblichen Farbdifferenz-Meßgerät aus. Die Farbmetrik arbeitet nach dem Dreibereichsverfahren. Alle Parameter werden ineinem Meßvorgang erfaßt und über einen Meßkonverter in einen Computer eingelesen. Die Darstellung des Farborts erfolgt im L,a b-System (CIELAB nach DIN 5033, DIN 6174), das der Physiologie des Sehens sehr nahekommt. Außerdem können Farbveränderungen über eine Farbabstandsformel (ΔE) weitgehend unabhängig vom Grundton der Haut analysiert werden. In ersten Ergebnissen von Messungen an Leichen zeigen sich regelhafte postmortale Abläufe der Farbveränderungen von Totenflekken bei zunehmender Druckstärke.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Deutsche Normen (1979) DIN 5033: Farbmessung. Normenausschuß Farbe (FNF) im DIN Deutsches Institut für Normung eV, Beuth, Berlin März 1979

    Google Scholar 

  2. Deutsche Normen (1979) DIN 6174: Farbmetrische Bestimmung von Farbabständen bei Körperfarben nach der CIE-LAB-Formel. Normenausschuß Farbe (FNF) im DIN Deutsches Institut für Normung eV, Beuth, Berlin Januar 1979

    Google Scholar 

  3. DiMaio DJ, DiMaio VJM (1989) Forensic Pathology. Elsevier, New York, pp 21–25

    Google Scholar 

  4. Fechner G, Koops E, Henßge C (1984) Zur Abblassung der Livores unter definierten Druckbedingungen. Z Rechtsmed 93:283–287

    PubMed  Google Scholar 

  5. Henßge C, Madea B (1988) Methoden zur Bestimmung der Todeszeit an Leichen. Arbeitsmethoden der medizinischen und naturwissenschaftlichen Kriminalistik Band 18. Schmidt-Römhild, Lübeck, pp 121–131

    Google Scholar 

  6. Hilgermann R (1972) Neuere histochemische Erkenntnisse über die sog. Diffusions-Totenflecke (keine perivasale Imbibition, sondern intravasale Hämokonzentration). Beitr Gerichtl Med 29:227

    Google Scholar 

  7. Hunnius P v, Mallach HJ, Mittmeyer HJ (1973) Über quantitative Druckmessungen an Totenflecken zur Bestimmung der Todeszeit. Z Rechtsmed 73:235–244

    PubMed  Google Scholar 

  8. Joachim H, Feldmann U (1980) Eine quantitative Methode der Todeszeitbestimmung durch Untersuchung der galvanischen Reizschwelle. Z Rechtsmed 85:5–22

    PubMed  Google Scholar 

  9. Kaatsch H-J, Mehrens C, Nietert M (1993) Der reproduzierbare Messerstich. Beitrag zur forensischen Beurteilung durchbohrender Stichvorgänge. Rechtsmedizin 3:67–76

    Google Scholar 

  10. Lins G (1968) Die Remissionsanalyse zur farblichen Charakterisierung der Leichenhaut. Beitr Gerichtl Med 24:162–166

    Google Scholar 

  11. Lins G (1973) Der Farbort der Totenflecken im Spektralfarbenzug. Beitr Gerichtl Med 31:203–212

    PubMed  Google Scholar 

  12. Madea B (1992) Längsschnittuntersuchungen zur supravitalen elektrischen Erregbarkeit der Skelettmuskulatur. Teil I: Objektivierung der supravitalen Muskelkontraktion. Rechtsmedizin 2:107–121

    Google Scholar 

  13. Madea B (1993) Längsschnittuntersuchungen zur supravitalen elektrischen Erregbarkeit der Skelettmuskulatur. Teil II: Extrapolation der Todeszeit und Präzision der Todeszeitschät-zung. Rechtsmedizin 3:44–50

    Google Scholar 

  14. Madea B, Henßge C (1990) Electrical excitability of skeletal muscle postmortem. Forensic Sci Int 47:207–227

    PubMed  Google Scholar 

  15. Mallach HJ (1964) Zur Frage der Todeszeitbestimmung. Berl Med 18:577–582

    Google Scholar 

  16. Mallach HJ, Mittmeyer HJ (1971) Totenstarre und Totenflecke. Z Rechtsmed 69:70–78

    PubMed  Google Scholar 

  17. Mittmeyer HJ (1971) Abhängigkeit der Totenstarre und Totenflecke vom Leichenalter. Beitr Gerichtl Med 28:101–107

    Google Scholar 

  18. Polson CJ, Gee DJ, Knight B (1985) The essentials of forensic medicine, 4th edn. Pergamon, Oxford New York, pp 13–15

    Google Scholar 

  19. Richter M (1981) Einführung in die Farbmetrik, 3. Aufl. de Gruyter, Berlin New York

    Google Scholar 

  20. Schneider V (1987) Die Leichenschau. Ein Leitfaden für Ärzte, Fischer, Stuttgart New York, pp 82–88

    Google Scholar 

  21. Schuller E, Pankratz H, Liebhardt E (1987) Farbortmessungen an Totenflecken. Beitr Gerichtl Med 45:169–173

    PubMed  Google Scholar 

  22. Schuller E, Pankratz H, Wohlrab H, Liebhardt E (1988) Die Bestimmung des Farbortes der Totenflecken in Beziehung zur Wegdrückbarkeit. In: Bauer G (Hrsg) Gerichtsmedizin: Festschrift für Wilhelm Holczabek. Franz Deuticke, Wien pp 295–302

    Google Scholar 

  23. Simpson K, Knight B (1985) Forensic Medicine. 9th edn. Arnold, London, pp 9–11

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kaatsch, H.J., Stadler, M. & Nietert, M. Photometric measurement of color changes in livor mortis as a function of pressure and time. Int J Leg Med 106, 91–97 (1993). https://doi.org/10.1007/BF01225047

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01225047

Key words

Schlüsselwörter

Navigation